ECB07/30/2026Worker that caused incident had not received site orientation as required in code 3301.11.1 & 2PROVIDE site safety orientation or refresher for all workers$5K due
ECB07/30/2026In response to an incident that occurred 7/29 around 4PM @ 4TH floor column 33 tile worker w/ no certification was operating an electrical pallet jack belonging to an electrical company struck an a frame dolly$5K due
ECB07/30/2026Worker who caused incident did not have a sst card available to present at time of inspection as required in code 3321.1 ensure each worker is in compliance with BC3321.1$10K due
ECB07/29/2026At time of inspection loose debris netting and debris observed at stairs creating trip hazards and unsafe conditions that can result in serious injuriesmaintain adequate construction housekeepingNothing owed — awaiting certificate of correction
ECB07/29/2026Observed improper ladder usage, above 6 ft, a frame ladder not opened and propped up against the wall contrary manufacturer specifications.comply with manufacturer specificationNothing owed — awaiting certificate of correction
ECB07/27/2026An incident that occurred on 7/16/26 at this jobsite where worker sustained a finger laceration, upon review of departmental records reveal that general contractor failed to submit report within 3 business daysHearing held — result not yet published$10K proposed
ECB07/14/2026Supported scaffold BC3314.1.@active site observe multiple supported scaffolds on site 1/2/4FRAMES highs not to code w/use of plywood for platform 3314.5.7¬ tied down 3314.5.5,no toe boards 3314.8.1, no tie-iNothing owed — awaiting certificate of correction
ECB06/17/2026At time of inspection observed an electrician with active sst card and attendance at the ladder stand down safety meeting held on 6/5/2025 utilizing a 6 ft ladder not in an open position & propped on the wall wNothing owed — awaiting certificate of correction
ECB06/04/2026Bc 3301.2 safety standards and measures- observed sunbelt truck reversing with no flaggers present creating hazardous conditions to vehicular traffic, bicyclists, and pedestrian foot traffic maintain flaggers fNothing owed — awaiting certificate of correction
ECB06/04/2026Bc 3301.2 safety measures and safeguards- observed exposed rebar at 5TH floor level with no control access zone in place, exposing trip and fall hazards that can lead to severe injuries or impalement. PreviousNothing owed — awaiting certificate of correction
ECB07/15/2021Boiler not registed 2-low water cut offs on 1- tapping,brick chimney this is gas,gas lines to regulator to be hard piped, maintain boiler; correct violation and send in certificate of correctionNothing owed — awaiting certificate of correction
ECB07/15/2021Boiler unregistered,2-low water cut offs on 1-tapping,exposed wires,gas line to regulator to be hard piped,condensate pump leaking, maintain boiler; correct all violations and send in certificate of correctionNothing owed — awaiting certificate of correction
ECB12/11/2018Failure to maintain building in code compliant manner. At time of inspection i observed missing dual female inlets, and was for siomese connnection sprinkler siomese is not painted, and no signage. Photos takenNothing owed — awaiting certificate of correction
ECB08/02/2017BC3308.1 vertical netting at time of inspection, observed that there was no vertical netting erected throughout site at leading edge of sty's and open areas, this condition of no netting creates a hazard of debNothing owed — awaiting certificate of correction
ECB08/02/2017BC3301.2 control access zone.@ the time of inspection of new stadium being erected i observed several areas thru-out site where there were no caz to stop persons from entering into open areas that had ongoingNothing owed — awaiting certificate of correction
ECB08/02/2017Toe board's at time of inspection of n.b. Observed that there were no toe boards at the leading edge of LEVEL2 throughout. This condition creates a hazard for person's working below from falling objects and conNothing owed — awaiting certificate of correction
ECB08/02/2017Guard rails at time of inspection observed that guardrail's were missing at 1 sty exp 1 near gate 3 entrance and exp 2, this condition of missing guardrails creates a fall hazard, stop all work 10FT in from opeNothing owed — awaiting certificate of correction
ECB05/18/2017Failure to maintain bldg walls noted: exp#2 wall (facade) has step cracks at various locations. Note: affected area located t corner of exposures 1 and 2 under pedestrian ramp. Rmdy: maintain exterior bldgNothing owed — awaiting certificate of correction
ECB04/19/2017Failure to safeguard all persons & property affected by construction oeprations,see swo#041917RH01 issued. Respodent above used a cat 325 track mounted machine w/a grappler attached to transport pile(60FT)causiNothing owed — awaiting certificate of correction
ECB02/12/201403X10,12Q07,15B07 - repair phone; guard lightbulbs in car; provide sign where and when certificate is and can be seen.Nothing owed — awaiting certificate of correction
ECB05/09/201266R05)work w/o a permit.installation of roper gripper which failed to activate contributing to adjacent on 5/4/12 remedy-file application & obtain permit-have device tested by DOB elevator inspector.Nothing owed — awaiting certificate of correction
ECB05/04/201259L10,16I10. 59L- repair machine brake. 16I- repair ("bk") level and promenade level hoistway doors, interlocks & facia. Requires full acceptance inspection by DOB elevation division. Call 212-566-5539 forNothing owed — awaiting certificate of correction
ECB05/04/201216D06,97X10. 16D- property secure ballroom level hoistway doorr. 97X- cease use device #4P4502 until proper accident inspection is performedby DOB. Call 212-566-5539 for re-inspection.Nothing owed — awaiting certificate of correction