← Back
Predominantly retail with other uses
533 86 STREET
BROOKLYN · BIN 3153219
💬 Discuss this project
1926Year Built
3Stories
K4Building Class
C4-2AZoning
3,408 sfGross Floor Area
3Units
2 Open Violations ▸FDNY Report ↗
Predominantly retail with other uses · Owner of record: 533 86TH STREET, LLC. · 1,862 sf lot · 1.83 FAR built · Flood zone X
Locations of Work
Architecture
Floor 11p · 1 filing · 16 docs
Cellar1p · 1 filing · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
533-86 ST1603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
INDETAIL ARCHITECTURAL AND ENGIN604/27/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HTX BUILDING CONSULTING603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CUBE BUILDERS GROUP NYGeneral Contractor403/22/2026
PETER LIElectrical303/21/2026
PIPESTYLISTSGeneral Contractor303/22/2026
P L ELECL CONTRG CORP 003654General Contractor303/22/2026
PIPESTYLISTS, INCPlumbing207/08/2026
LINVAL BROWNElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
INDETAIL DESIGN ARCHITECT4828604/27/2022
Building Lifecycle
All (63)Filed (6)Permit Issued (2)Signed Off (2)Violation (9)Inspection (7)Objection (16)Special Inspection (21)
03/30/2026
Violation issued (FDNY_NOV, closed)
07/25/2022
Signed off — Alteration
file plumbing work type in-conjunction with application# B00574013-I1
B00586477-I1
07/18/2022
Signed off — Alteration
Interior renovation on extg. eating and drinking space. No change in use, occupancy and egress.
B00574013-I1
07/18/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/15/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/27/2022
Filed — Alteration
Interior renovation on extg. eating and drinking space. No change in use, occupancy and egress.
B00574013-P2
04/26/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jonathan Chin
04/26/2022
Special inspection requirement — Interior lighting power
Jonathan Chin
04/26/2022
Special inspection requirement — Lighting controls
Jonathan Chin
04/26/2022
Special inspection requirement — Insulation placement and R values
Jonathan Chin
04/26/2022
Special inspection requirement — Fire-Resistance Rated Construction
Jonathan Chin
04/26/2022
Special inspection requirement — Energy Code Compliance Inspections
Jonathan Chin
04/08/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jonathan Chin
04/08/2022
Special inspection requirement — Energy Code Compliance Inspections
Jonathan Chin
04/08/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Jonathan Chin
04/07/2022
Filed — Alteration
file plumbing work type in-conjunction with application# B00574013-I1
B00586477-P2
04/04/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Jonathan Chin
04/04/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jonathan Chin
04/04/2022
Special inspection requirement — Energy Code Compliance Inspections
Jonathan Chin
03/04/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/02/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/29/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/08/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/08/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/25/2021
Filed — Alteration
Interior renovation on extg. eating and drinking space. No change in use, occupancy and egress.
B00574013-P1
10/25/2021
Filed — Alteration
file plumbing work type in-conjunction with application# B00574013-I1
B00586477-P1
10/25/2021
Special inspection requirement — Interior lighting power
Jonathan Chin
10/25/2021
Special inspection requirement — Fire-Resistance Rated Construction
Jonathan Chin
10/25/2021
Special inspection requirement — Energy Code Compliance Inspections
Jonathan Chin
10/25/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jonathan Chin
10/25/2021
Special inspection requirement — Energy Code Compliance Inspections
Jonathan Chin
10/25/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
Jonathan Chin
10/25/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jonathan Chin
10/25/2021
Special inspection requirement — Lighting controls
Jonathan Chin
10/25/2021
Special inspection requirement — Insulation placement and R values
Jonathan Chin
09/29/2021
Permit issued — Plumbing
B00586477-I1-PL
09/15/2021
Permit issued — General Construction
B00574013-I1-GC
09/02/2021
Objection raised — Scope
09/02/2021
Objection resolved — Addressed
09/02/2021
Objection raised — Other
09/02/2021
Objection resolved — Addressed
09/01/2021
Filed — Alteration
file plumbing work type in-conjunction with application# B00574013-I1
B00586477-I1
08/23/2021
Objection raised — Accessibility
08/23/2021
Objection resolved — Addressed
08/23/2021
Objection raised — Structural
08/23/2021
Objection resolved — Addressed
08/23/2021
Objection raised — Scope
08/23/2021
Objection resolved — Addressed
08/23/2021
Objection raised — Fire_Protection
08/23/2021
Objection resolved — Addressed
08/23/2021
Objection raised — Inspections
08/23/2021
Objection resolved — Addressed
08/23/2021
Objection raised — Scope
08/23/2021
Objection resolved — Addressed
08/20/2021
Filed — Alteration
Interior renovation on extg. eating and drinking space. No change in use, occupancy and egress.
B00574013-I1
05/04/2004
Violation issued (HPD, open)
B
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/01/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/16/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Latest 60 of 63 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offT & T PLUMBING INC09/29/2021
DOB NOWGeneral ConstructionSigned-offCUBE BUILDERS GROUP NY09/15/2021
BISPLISSUEDGAS APPROVED SERVICE CORP04/13/2016
BISMHISSUEDJ. AND F. REFRIGERATION,*04/06/2016
BISPLISSUEDTHE PLUMBING COMPANY INC08/15/2011
BISOTISSUEDAIRITAN CONSTR CORP08/10/2011
BISPLISSUEDATTACK PLUMBING INC12/16/2010
BISMHISSUEDJ. AND F. REFRIGERATION,*02/05/2009
BISOTISSUEDVASMO CORPORATION03/13/2008
BISFPISSUEDCHIEF FIRE PREVENTION & MECH02/24/2006
BISMHISSUEDULTIMATE ALTERATIONS07/21/2004
BISFPISSUEDNY BUSINESS FIRE SYSTEM INC.04/25/2003
BISPLISSUEDPETER PLUMBING ASSOC. INC.03/21/2003
BISOTISSUEDEAGLE NORTH EAST INTERIOR INC03/11/2003
BISEQISSUEDEAGLE NORTH EAST INTERIOR INC03/11/2003
1 project · most recent 09/20/2021
General Wiring
FiledStatusContractorScope
09/20/2021CompleteP.L. ELEC'L CONTR'G CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
07/18/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/15/2022Pass-Final General Construction Non-Directive 14PassView ↗
03/04/2022Fail-Final General Construction Non-Directive 14FailView ↗
03/02/2022Fail-Final General Construction Non-Directive 14FailView ↗
11/29/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/08/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/08/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 21
DateRequirementInspectorRole
04/26/2022Fire-Resistant Penetrations and JointsJonathan Chinspecial
04/26/2022Interior lighting powerJonathan Chinenergy_progress
04/26/2022Lighting controlsJonathan Chinenergy_progress
04/26/2022Insulation placement and R valuesJonathan Chinenergy_progress
04/26/2022Fire-Resistance Rated ConstructionJonathan Chinprogress
04/26/2022Energy Code Compliance InspectionsJonathan Chinprogress
04/08/2022Fire-Resistant Penetrations and JointsJonathan Chinspecial
04/08/2022Energy Code Compliance InspectionsJonathan Chinprogress
04/08/2022HVAC-R and service water piping design and insulationJonathan Chinenergy_progress
04/04/2022HVAC-R and service water piping design and insulationJonathan Chinenergy_progress
04/04/2022Fire-Resistant Penetrations and JointsJonathan Chinspecial
04/04/2022Energy Code Compliance InspectionsJonathan Chinprogress
10/25/2021Interior lighting powerJonathan Chinenergy_progress
10/25/2021Fire-Resistance Rated ConstructionJonathan Chinprogress
10/25/2021Energy Code Compliance InspectionsJonathan Chinprogress
10/25/2021Fire-Resistant Penetrations and JointsJonathan Chinspecial
10/25/2021Energy Code Compliance InspectionsJonathan Chinprogress
10/25/2021HVAC-R and service water piping design and insulationJonathan Chinenergy_progress
10/25/2021Fire-Resistant Penetrations and JointsJonathan Chinspecial
10/25/2021Lighting controlsJonathan Chinenergy_progress
10/25/2021Insulation placement and R valuesJonathan Chinenergy_progress
▾Documents — 96 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
09/01/2026B00574013-P1Request digital key ↗
09/01/2026B00574013-P2Request digital key ↗
09/01/2026B00586477-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits10
▸BISPLAN / WORK APPROVAL APPLICATION6
04/27/2023310081041Open ↗
04/24/2023310081041Open ↗
04/20/2023310081041Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION4
04/14/2016321317561Open ↗
04/07/2016321317561Open ↗
02/05/2009310081041Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications30
▸DOB NOWProgress Inspector Seal & Signature10
09/18/2026B00586477-P1Open ↗
09/18/2026B00586477-P1Open ↗
09/02/2026B00586477-P2Open ↗
Showing 3 of 10 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
06/17/2016321317561Open ↗
04/07/2016321317561Open ↗
04/05/2016321317561Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
09/01/2026B00574013-P2Open ↗
09/01/2026B00574013-P1Open ↗
09/01/2026B00574013-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/18/2026B00586477-P1Open ↗
09/02/2026B00586477-P2Open ↗
09/01/2026B00586477-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPC FULL REPORT1
02/05/2008310081041Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/05/2008310081041Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
02/05/2008310081041Open ↗
▸Trade Schedules & Equipment8
▸BISEQUIPMENT USE APPLICATION/PERMIT3
06/17/2016321317561Open ↗
04/06/2016321317561Open ↗
02/05/2008310081041Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
10/08/2011320343954Open ↗
09/23/2011320343954Open ↗
▸BISEQUIPMENT USE PERMITS1
06/17/2016321317561Open ↗
▸BISSCHEDULE B - PLUMBING1
10/24/2011320343954Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
04/06/2016321317561Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes1
04/06/2016321317561Open ↗
▸BISSTREET TREE CHECKLIST1
04/06/2016321317561Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
09/01/2026B00574013-P1Open ↗
09/01/2026B00574013-P2Open ↗
09/01/2026B00586477-P1Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
10/24/2011320343954Open ↗
02/05/2008310081041Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
06/17/2016321317561Open ↗
04/07/2016321317561Open ↗
04/06/2016321317561Open ↗
▸DOB NOWEN2: As Built Energy Analysis.2
08/15/2026B00586477-I1Open ↗
08/15/2026B00574013-I1Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/17/2016321317561Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY4
05/18/2023310081041Open ↗
05/18/2023310081041Open ↗
04/20/2023310081041Open ↗
Showing 3 of 4 on file for this type
▸BIS* FINAL INSPECTION DIRECTIVE 14 OF 19752
05/01/2023310081041Open ↗
05/01/2023310081041Open ↗
▸BIS* STRUCTURAL STABILITY 1 RCNY:16-011
05/02/2023310081041Open ↗
▸Approvals, Objections & Sign-offs6
▸BISADMINISTRATIVE OBJECTIONS3
04/06/2016321317561Open ↗
10/24/2011320343954Open ↗
01/24/2008310081041Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
05/18/2023310081041Open ↗
06/17/2016321317561Open ↗
08/01/2012320343954Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT5
06/17/2016321317561Open ↗
04/06/2016321317561Open ↗
08/01/2012320343954Open ↗
Showing 3 of 5 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
05/01/2023310081041Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
04/06/2016321317561Open ↗
10/24/2011320343954Open ↗
▸BISADDITIONAL INFORMATION1
09/26/2011320343954Open ↗
▸Other Documents4
▸BIS* VENT. SYS.-ENGINEER/INSTALLER 27-136,7792
05/01/2023310081041Open ↗
05/01/2023310081041Open ↗
▸BIS* FIRE STOPS 27-3452
05/01/2023310081041Open ↗
05/01/2023310081041Open ↗