HPD05/20/2024§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
HPD05/18/2024§ 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ACCUMULATION OF WATER AND RAW SEWAGE AT NORTH YARD
HPD05/18/2024§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 15SQ FT OF MOLD AT CEILING IN THE BATHROOM LOCATED AT APT 2BSIDE, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/18/2024§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ELECTICAL WIRES AT WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 2BSIDE, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/18/2024§ 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT WATER CLOSET AND WASH BASIN IN THE BATHROOM LOCATED AT APT 2BSIDE, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/18/2024§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 2BSIDE, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/18/2024§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 15SQ FT OF MOLD AT CEILING AND WEST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 2BSIDE, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/03/2024§ 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING. IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/03/2024§ 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING. IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/03/2024§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING(10 SQ.FT) IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/03/2024§ 27-2073 ADM CODE - DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE MICOWAVE BEING USE FOR COOKING AT REAR EXTENSION , 1st STORY
HPD05/03/2024§ 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF TWO ROOMS CREATED FOR LIVING AND PLUMBING FIXTURES CONSISTING OF WATER WATER CLOSET WASH BASIN AND SHOWER STALL CREATING A BATHROOM AT REAR EXTENSION OF THE BUILDING , 1st STORY
HPD02/19/2023§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD02/19/2023§ 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 1st STORY
HPD02/19/2023§ 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES ... IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD01/03/2023§ 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF TWO ROOM FOR LIVING AND PLUMBING FIXTURES CONSISTING OF WATER CLOSET, WASH BASIN AND SHOWER STALL CREATING BATHROOM AT REAR EXTENTION OF BUILDING
HPD01/03/2023§ 27-2073 ADM CODE - DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE ELECTRIC RANGE FOR COOKING IN REAR EXTENTION OF BUILDING
HPD01/03/2023§ 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT LOCATED AT APT 2BBACK, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''(REAR)''
HPD11/07/2022§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
HPD11/04/2022§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE. IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
ECB09/19/2024OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O AND/OR DEPARTMENT OF BUILDING RECORDS. PARTITIONS ERECTED CREATING ILLEGAL ROOMS FOR LIVING ANDSLEEPING AT 1ST-STORY REAR EXTENSION. FULL BATHROOM PRESENT COMPLETEDNothing owed — awaiting certificate of correction
ECB01/03/2023OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS. ILLEGAL ROOMS IN 1ST STORY WITH KITCHEN AND BATHROOM FACILITIES INSTALLED. REMEDY: DISCONTINUE ILLEGAL USENothing owed — awaiting certificate of correction