← Back
Cape Cod
54-07 84 STREET
QUEENS · BIN 4065698
💬 Discuss this project
1945Year Built
1.67Stories
A0Building Class
R5Zoning
1,492 sfGross Floor Area
1Units
Cape Cod · 3,693 sf lot · 0.4 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 8 docs
Cellar1p · 1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ZHENG & ASSOCIATES LLC107/15/2026
Building Lifecycle
All (53)Filed (1)Objection (22)Special Inspection (30)
09/11/2026
Objection resolved — Resolved
09/11/2026
Objection resolved — Resolved
09/11/2026
Objection resolved — Resolved
09/11/2026
Objection resolved — Resolved
09/11/2026
Objection resolved — Resolved
09/11/2026
Objection resolved — Resolved
09/11/2026
Objection resolved — Resolved
08/22/2026
Objection resolved — Resolved
08/22/2026
Objection resolved — Resolved
08/22/2026
Objection resolved — Resolved
08/22/2026
Objection resolved — Resolved
08/21/2026
Objection raised — Admin
08/21/2026
Objection raised — Inspections
08/21/2026
Objection raised — Other
08/21/2026
Objection raised — Scope
08/21/2026
Objection raised — Admin
08/21/2026
Objection raised — Structural
08/21/2026
Objection raised — Energy
08/21/2026
Objection raised — Zoning
08/21/2026
Objection raised — Zoning
08/21/2026
Objection raised — Scope
08/21/2026
Objection raised — Zoning
07/15/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
ENLARGE & CONVERT EXISTING ONE FAMILY INTO TWO FAMILY DWELLING UNITS.
Q01423897-I1
07/13/2026
Special inspection requirement — Ventilation and air distribution system
07/13/2026
Special inspection requirement — Permanent certificate
07/13/2026
Special inspection requirement — Maintenance information
07/13/2026
Special inspection requirement — Protection of exposed foundation insulation
07/13/2026
Special inspection requirement — Metering
07/13/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
07/13/2026
Special inspection requirement — Concrete - Cast-In-Place
07/13/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
07/13/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/13/2026
Special inspection requirement — Heating Systems
07/13/2026
Special inspection requirement — Structural Steel - High Strength Bolting
07/13/2026
Special inspection requirement — Wood – Metal-Plate-Connected Trusses
07/13/2026
Special inspection requirement — Energy Code Compliance Inspections
07/13/2026
Special inspection requirement — Fire-Resistance Rated Construction
07/13/2026
Special inspection requirement — Structural Wood Frame
07/13/2026
Special inspection requirement — HVAC-R and service water heating system controls
07/13/2026
Special inspection requirement — Air barrier — testing
07/13/2026
Special inspection requirement — Air barrier - visual inspection
07/13/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
07/13/2026
Special inspection requirement — Fenestration air leakage
07/13/2026
Special inspection requirement — Insulation placement and R values
07/13/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
07/13/2026
Special inspection requirement — Fenestration areas
07/13/2026
Special inspection requirement — Interior lighting power
07/13/2026
Special inspection requirement — HVAC-R and service water heating equipment
06/29/2026
Special inspection requirement — Structural Steel - Details
06/29/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/29/2026
Special inspection requirement — Mechanical Systems
06/29/2026
Special inspection requirement — Footing and Foundation
06/29/2026
Special inspection requirement — Final
Nothing on file for this building.
1 project · most recent 07/15/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/15/2026——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin 4MXM36AVJU9 34,600 BTU · Heat Pump Outdoor ×2
RMXS48LVJU 54,000 BTU · Heat Pump Outdoor ×2
Ventilation
Broan HRV250ECM 250 CFM · Erv ×2
1 project · most recent 07/15/2026
Sprinkler System
FiledStatusContractorScope
07/15/2026——Sprinkler System
1 project · most recent 07/15/2026
Steel Wood
FiledStatusContractorScope
07/15/2026——Steel, Wood
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
07/13/2026Ventilation and air distribution system—energy_progress
07/13/2026Permanent certificate—energy_progress
07/13/2026Maintenance information—energy_progress
07/13/2026Protection of exposed foundation insulation—energy_progress
07/13/2026Metering—energy_progress
07/13/2026Subsurface Investigations (Borings/Test Pits)—special
07/13/2026Concrete - Cast-In-Place—special
07/13/2026Excavations - Sheeting, Shoring, and Bracing—special
07/13/2026Fire-Resistant Penetrations and Joints—special
07/13/2026Heating Systems—special
07/13/2026Structural Steel - High Strength Bolting—special
07/13/2026Wood – Metal-Plate-Connected Trusses—special
07/13/2026Energy Code Compliance Inspections—progress
07/13/2026Fire-Resistance Rated Construction—progress
07/13/2026Structural Wood Frame—progress
07/13/2026HVAC-R and service water heating system controls—energy_progress
07/13/2026Air barrier — testing —energy_progress
07/13/2026Air barrier - visual inspection—energy_progress
07/13/2026HVAC-R and service water piping design and insulation—energy_progress
07/13/2026Fenestration air leakage—energy_progress
07/13/2026Insulation placement and R values—energy_progress
07/13/2026Fenestration and door U-factor and product ratings—energy_progress
07/13/2026Fenestration areas—energy_progress
07/13/2026Interior lighting power—energy_progress
07/13/2026HVAC-R and service water heating equipment—energy_progress
Latest 25 of 30.
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026Q01423897-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/16/2026Q01423897-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/16/2026Q01423897-S1Open ↗
08/16/2026Q01423897-I1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/16/2026Q01423897-I1Open ↗
▸DOB NOWSOIL REPORT1
08/16/2026Q01423897-I1Open ↗
▸Other Documents3
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/16/2026Q01423897-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/16/2026Q01423897-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/16/2026Q01423897-I1Open ↗