← Back
Two family converted from one family
54-74 83 STREET
QUEENS · BIN 4066217
💬 Discuss this project
1940Year Built
2Stories
B3Building Class
R4Zoning
1,520 sfGross Floor Area
2Units
Two family converted from one family · 2,500 sf lot · 0.61 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/12/2024$998K—Private party → Private party$657/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VALENTINO POMPEO ARCHITECT, P.C.204/19/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MEGA ELEC'L CONTR'G, INCElectrical203/22/2026
EJP CONTRACTING CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
P GEORGOPOULOS ARCHITECT889204/19/2024
Building Lifecycle
All (19)Filed (2)Permit Issued (1)Signed Off (1)Inspection (2)Objection (6)Special Inspection (7)
07/03/2024
Signed off — Alteration
FIRE DAMAGE REPAIR OF EXISTING 2 FAMILY BUILDING, NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00895815-I1
07/02/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/21/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
05/17/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Vasilios Georgopoulos
05/17/2024
Special inspection requirement — Energy Code Compliance Inspections
Vasilios Georgopoulos
05/17/2024
Special inspection requirement — Fenestration areas
Vasilios Georgopoulos
05/17/2024
Special inspection requirement — Interior lighting power
Vasilios Georgopoulos
05/17/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Vasilios Georgopoulos
05/17/2024
Special inspection requirement — Air barrier - visual inspection
Vasilios Georgopoulos
05/17/2024
Special inspection requirement — Fenestration air leakage
Vasilios Georgopoulos
05/05/2024
Objection raised — Scope
05/05/2024
Objection resolved — Addressed
04/19/2024
Filed — Alteration
FIRE DAMAGE REPAIR OF EXISTING 2 FAMILY BUILDING, NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00895815-P1
10/16/2023
Permit issued — General Construction
Q00895815-I1-GC
09/29/2023
Objection resolved — Addressed
09/28/2023
Objection resolved — Addressed
07/13/2023
Objection raised — Energy
07/13/2023
Objection raised — Other
06/28/2023
Filed — Alteration
FIRE DAMAGE REPAIR OF EXISTING 2 FAMILY BUILDING, NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00895815-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offEJP CONTRACTING CORP10/16/2023
1 project · most recent 09/19/2024
General Wiring
FiledStatusContractorScope
09/19/2024CompleteMEGA ELEC'L CONTR'G, INCGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/02/2024Pass-Final General Construction Non-Directive 14PassView ↗
06/21/2024Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
05/17/2024Fire-Resistant Penetrations and JointsVasilios Georgopoulosspecial
05/17/2024Energy Code Compliance InspectionsVasilios Georgopoulosprogress
05/17/2024Fenestration areasVasilios Georgopoulosenergy_progress
05/17/2024Interior lighting powerVasilios Georgopoulosenergy_progress
05/17/2024Fenestration and door U-factor and product ratingsVasilios Georgopoulosenergy_progress
05/17/2024Air barrier - visual inspectionVasilios Georgopoulosenergy_progress
05/17/2024Fenestration air leakageVasilios Georgopoulosenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026Q00895815-I1Request digital key ↗
08/14/2026Q00895815-P1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026Q00895815-I1Open ↗
08/13/2026Q00895815-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026Q00895815-I1Open ↗
08/23/2026Q00895815-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q00895815-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/24/2026Q00895815-I1Open ↗
08/13/2026Q00895815-P1Open ↗