HPD08/24/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILINGS AND WALLS THRU-OUT ALL ROOMS IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD08/24/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SINKING WOOD SUBFLOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD06/10/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD06/10/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD06/07/2026§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD06/07/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD03/28/2024§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT FLOORING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
ECB02/24/2022FOUND FEDERAL FST-60 BOILER NOT REGISTERED WITH DOB, PULL PERMIT BRING BOILER AND BOILER ROOM UP TO CODE AND CALL FOR INSPECTION, ANTI SIPHON AND SHUT OFF VALVE MISSING AT TOP OF TANK.$37 due
ECB06/03/2021NO ANTI SIPHON, NO OIL SHUT OFF VALVE-LWC AND W COLUMN DRAIN NOT SEPARATE-SAFETY VALVE DISCH. NO SUPP-W PIPE LEAK FROM CEIL-NO DISCH C. PRES. RELIEF-NO CHECK VALVE ON FW PIPE-NO DRIP ON BACK FLOW; CORRECT ALL VNothing owed — awaiting certificate of correction
ECB01/30/2020UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT APPRARATUS MATERIALSDEVICES APPLIANCES OR WIRING IN USE.OBSERVED ON THE 2ND FLOOR ONE OPE N UNCOVERED 1900 JUNCTION BOX 2ND FLOOR HALL WAY.HAD NO ACCESS TO APARNothing owed — awaiting certificate of correction
ECB08/16/2017B254,36. 36-AS PER CLASS 254-36. BOILER NOT REGISTERED AS PER DOB RECORDS. CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION.Nothing owed — awaiting certificate of correction
ECB10/18/2014B101 WORK W/O A PERMIT. EASTMOND BOILER. FST-60 ICBURNER VLG-25.Nothing owed — awaiting certificate of correction
ECB10/18/2014B254,15,16,24A,32A,34A,40,50A,50B,50C,50D,50E,50F,50G,50H,50I.50A-DOORTO BOILER ROOM NOT EGRESS; 50B-EXPOSED WIRES ALL OVER BOILER ROOM; 50CCONTROLS NOT CONNECTED COVERS MISSING; 50D-WATER LEAKING FROM WATER PINothing owed — awaiting certificate of correction
ECB03/25/2014FAILURE TO MAINTAIN BLDG NOTED:AT PARAPET WALL FACING WALTON AVE,FOUNDVERTICAL CRACK APPROX 3/4"X 2 1/2'.AFFECTED SECTION NOT LEANING @ TIMEOF INSPECTION.REM:REPAIR DEFECTS FORTHWITH & MAINTAIN BLDG.Nothing owed — awaiting certificate of correction
ECB03/25/2014FAILURE TO MAINTAIN BLDG NOTED:WALLS AND CEILING IN APT 5D HAVE BEGAN DAMAGED BY WATER LEAKS FROM ROOF.OBSERVED LRG AREAS OF MILDEW AND SPALLING PLASTER.REM:REPAIR DEFECTS & MAINTAIN BLDG.Nothing owed — awaiting certificate of correction
ECB01/08/201034A,9A,50ABCD:50A-FLUE PIPE NEED SUPPORT,50B-CONTROL COVERS MISSING 50C-NO R STAMP AS PER CODE FOR WILDING ON BOILERS 50D-NO CLEAN OUT ON CHIMNEY BASE.Nothing owed — awaiting certificate of correction
ECB01/08/201050AB: 50A WORK W/O A PERMIT 28-105.1 50B-NO WORK PERMIT FILED WITH DOBFROM THE REPLACEMENT DI/BURMANNothing owed — awaiting certificate of correction