← Back
BuildNYC
Two family frame
54 RIDGECREST AVENUE
STATEN ISLAND · BIN 5068125
💬 Discuss this project
2023Year Built
2Stories
B2Building Class
R3AZoning
2,227 sfGross Floor Area
2Units
0 Active ViolationsFDNY Report ↗
Two family frame · 3,749 sf lot · 0.59 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingFire ProtectionCivil
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof3p · 1 filing · 20 docs
Attic2p · 1 filing · 20 docs
Floor 26p · 1 filing · 20 docs
Floor 15p · 1 filing · 20 docs
Basement5p · 1 filing · 20 docs
Site & exterior2p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Rogers Calvanico Group403/22/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Rogers Calvanico Group403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Statcon DevelopmentGeneral Contractor303/21/2026
S Demaio PLG HeatingPlumbing103/21/2026
JB Buzco PlumbingPlumbing107/08/2026
Perciballi IndustriesGeneral Contractor104/28/2022
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A Tech Engineering NYC, P6738503/22/2023
Rogers Calvanico Group1324203/22/2023
Building Lifecycle
11/12/2023
Permit expired, never signed off — Earth Work
The city's record still shows this permit as issued, with no sign-off on its filing
S00769218-I1-GC-CX
06/27/2023
Signed off — New Building
CONSTRUCT DETACHED TWO FAMILY RESIDENCE WITH ACCESSORY OFF STREET PARKING FOR 2 CARS AND DETACHED ONE CAR GARAGE ON LOT.
S00769218-S1
06/12/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/28/2023
Objection raised — Scope
03/28/2023
Objection resolved — Addressed
45 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJB Buzco Plumbing12/16/2022
DOB NOWEarth WorkPermit IssuedStatcon Development11/12/2022
BIS—ISSUEDPerciballi Industries04/28/2022
BISCCISSUEDN/A11/04/1999
BISPLISSUEDS.demaio PLG. & Heating01/12/1998
BIS—ISSUEDJohn Depalma10/30/1997
1 project · most recent 02/23/2023
General Wiring
FiledStatusContractorScope
02/23/2023CompleteD and H Electrical ConstructionGeneral Wiring
1 project · most recent 03/22/2023
Wood
FiledStatusContractorScope
03/22/2023Signed-offJB Buzco PlumbingWood
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
06/12/2023Pass-Final CND-Occupancy InspectionPassView ↗
03/14/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/21/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/21/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
03/28/2023Subsurface Investigations (Borings/Test Pits)anthony santorospecial
03/28/2023Exterior Insulation and Finish Systems (EIFS)anthony santorospecial
03/28/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationRichard Daileyspecial
03/28/2023Mechanical Systemsanthony santorospecial
03/28/2023Concrete - Cast-In-Placeanthony santorospecial
03/28/2023Fire-Resistant Penetrations and Jointsanthony santorospecial
03/28/2023Wood – Prefabricated I-Joistsanthony santorospecial
03/28/2023Subgrade Inspectionsanthony santorospecial
03/28/2023Structural Wood Frameanthony santoroprogress
03/28/2023Energy Code Compliance Inspectionsanthony santoroprogress
03/28/2023Fire-Resistance Rated Constructionanthony santoroprogress
03/28/2023Footing and Foundationanthony santoroprogress
03/28/2023Finalanthony santoroprogress
03/28/2023Duct leakage testing, insulation and designanthony santoroenergy_progress
03/28/2023Interior lighting poweranthony santoroenergy_progress
03/28/2023HVAC-R and service water heating equipmentanthony santoroenergy_progress
03/28/2023Protection of exposed foundation insulationanthony santoroenergy_progress
03/28/2023Fenestration areasanthony santoroenergy_progress
03/28/2023Air barrier - visual inspectionanthony santoroenergy_progress
03/28/2023Air barrier — testing anthony santoroenergy_progress
03/28/2023Fenestration and door U-factor and product ratingsanthony santoroenergy_progress
03/28/2023Insulation placement and R valuesanthony santoroenergy_progress
03/28/2023Permanent certificateanthony santoroenergy_progress
03/28/2023HVAC-R and service water piping design and insulationanthony santoroenergy_progress
03/28/2023Maintenance informationanthony santoroenergy_progress
Latest 25 of 32.
61 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account