DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 INTERNAL HGH PRESSURE INSPECTION
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL HGH PRESSURE INSPECTION
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL HGH PRESSURE INSPECTION
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 INTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 INTERNAL HGH PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 INTERNAL HIGH PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL HIGH PRESSURE INSPECTION
DOB03/16/2020VIOLATION ISSUED - FAILURE TO FILE 2017 INTERNAL HIGH PRESSURE BOILER INSPECTION
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
ECB06/21/2006CEASE USE/HAZARDOUS 3A,51,48B,18A,18B,40,50A, 3A-FLU PIPE CORRODED & IN DANGER OF COLLAPSING. 50A - SLOW OPENING VALUE ON BOILER BLOW DOWN MUST BE TERMINATING LAST. (REVERSE)$-25 due
DOB01/06/2006V-DOB VIOLATION - ACTIVE
DOB01/31/2005V-DOB VIOLATION - ACTIVE
HPD03/03/2004SECTION 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILINGS & WALLS ALL ROOMS 3RD STY APT.
HPD03/03/2004SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR 3RD STY PUBLIC HALL SCUTTLE CLOSET
DOB02/13/2004V-DOB VIOLATION - ACTIVE
HPD07/17/2003SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WALLS AN DCEILING 3RD STY PUBLIC HALL SCUTTLE CLOSET
HPD07/17/2003SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT WALLS 3RD STY PUBLIC HALL
DOB03/26/2002V-DOB VIOLATION - ACTIVE
DOB02/27/2001V-DOB VIOLATION - ACTIVE
DOB02/07/2000V-DOB VIOLATION - ACTIVE
DOB09/16/1997V-DOB VIOLATION - ACTIVE
DOB02/10/1997V-DOB VIOLATION - ACTIVE
DOB08/29/1995V-DOB VIOLATION - ACTIVE
DOB06/01/1994V-DOB VIOLATION - ACTIVE
DOB08/16/1993V-DOB VIOLATION - ACTIVE
DOB06/01/1993V-DOB VIOLATION - ACTIVE
DOB12/01/1992VP-VIOLATION UNSERVED ECB-ACTIVE
ECB11/22/2016B254,50A,3A,4B,50A,50B,50C. FULTON V.T. BLK,15HP NB 78255 HP SM, OIL FIRED BUILT 1997. 3A-SURFACE CORROSION OF SECTIONS OF THE FLUE PIPE RUN REPLACE 50A-UPPER AND LOWER HAND HOLE SLEEVES CORRODED/REPLC; 48ABNothing owed — awaiting certificate of correction
ECB11/23/200918/38/40/48A/40-MUST HAVE SINGLE SWING DRAFT-O-STAT (OIL)/18-HAND HOLECORRODED/38-NO FIXED VENTILATION/48A-GAUGE GLASS LEAKINGNothing owed — awaiting certificate of correction
ECB05/18/2009FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. AT TIME OF INSPOBSERVED AT FRONT OF PREMISES, AT 3RD LEVEL THE SOUTHERN MOST WINDOWS BOTTOM SASH HAS A BROKEN PANE OF GLASS & AT INTERIOR OF THAT THE 3RD FNothing owed — awaiting certificate of correction
ECB06/25/200818B 48B 50A 50B 50C 50D 50A-INSTALL STRUCTURAL SUPPORT ON FLUE THREADED ROD & CHANNEL 50B REPAIR CEILING ABOVE BOILER FLUE PIPE 50C REVERSE BLOW DOWN VALVE TO TERMINATE LAST 50D LEAK ON FEED LINE.Nothing owed — awaiting certificate of correction
ECB06/21/2006BQ9,19B,50A. BQ9-INSTAL OF A GAS NEW YORKER BOILER W/O OBTAINING A PERMIT OR APPROVAL FRM DOB. 50A- CHIMNEY BASE NOT SEALED, 50B-FLU PIPE FROM BOILER NOT PROPERLY PITCHED UPWARDS. 50C-INSTALL BK FLOW PREVENTER.Nothing owed — awaiting certificate of correction
ECB12/23/199225,32 REPLACE SAFETY VALVE WITH A NEW ONENothing owed — awaiting certificate of correction
Primarily 2 family with 1 store or office · Owner of record: 5403 13 AVE. · 1,840 sf lot · 2.05 FAR built · Flood zone X