← Back
Two family converted from one family
5424 AVENUE O
BROOKLYN · Flatlands · BIN 3239803
💬 Discuss this project
1955Year Built
2Stories
B3Building Class
R5Zoning
1,980 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 2,000 sf lot · 0.99 FAR built · Flood zone X500
Locations of Work
Electrical
Roof1p · 1 filing · 3 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JBA104/26/2024
TOM PETERSEN ARCHITECT, LLC101/22/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KC EXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SOLAR PRO INCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WORLD DESIGN ARCHITECTURE9323104/26/2024
THOMAS PETERSEN ARCHITECT7854101/22/2024
Building Lifecycle
All (19)Filed (2)Permit Issued (2)Signed Off (1)Violation (1)Objection (8)Special Inspection (5)
09/10/2024
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B01042541-I1
06/06/2024
Permit issued — Solar
B01042541-I1-SL
05/17/2024
Objection resolved — Addressed
05/17/2024
Objection resolved — Addressed
05/10/2024
Objection raised — Other
05/10/2024
Objection resolved — Addressed
05/10/2024
Objection raised — Fire_Protection
05/07/2024
Objection raised — Other
05/07/2024
Objection raised — Other
05/07/2024
Objection resolved — Addressed
04/26/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B01042541-I1
04/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
04/26/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
William Alicea
04/26/2024
Special inspection requirement — Energy Code Compliance Inspections
JEFFREY BELL
04/26/2024
Special inspection requirement — Final
JEFFREY BELL
04/26/2024
Special inspection requirement — Air barrier - visual inspection
JEFFREY BELL
01/25/2024
Permit issued — Solar
B00993849-I1-SL
01/22/2024
Filed — Alteration
B00993849-I1
08/25/2016
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSOLAR PRO INC06/06/2024
DOB NOWSolarPermit IssuedTOM PETERSEN ARCHITECT, LLC01/25/2024
2 projects · most recent 04/18/2024
FiledStatusContractorScope
04/18/2024CompleteVILLAGE ELECTL CONTRS INC—
01/19/2024CancelledVENTURE HOME SOLAR LLC—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/26/2024Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
04/26/2024Structural Stability – Alterations of existing buildingsWilliam Aliceaspecial
04/26/2024Energy Code Compliance InspectionsJEFFREY BELLprogress
04/26/2024FinalJEFFREY BELLprogress
04/26/2024Air barrier - visual inspectionJEFFREY BELLenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/26/2026B00993849-I1Request digital key ↗
08/25/2026B01042541-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/23/2026B01042541-I1Open ↗
08/23/2026B01042541-I1Open ↗
08/23/2026B01042541-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026B00993849-I1Open ↗
08/13/2026B01042541-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026B01042541-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/26/2026B00993849-I1Open ↗
08/13/2026B01042541-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01042541-I1Open ↗