← Back
Converted dwellings or rooming house
544 WEST 142 STREET
MANHATTAN · Hamilton Heights-Sugar Hill · BIN 1061821
💬 Discuss this project
1910Year Built
3Stories
C5Building Class
R6AZoning
2,649 sfGross Floor Area
7Units
Converted dwellings or rooming house · 1,699 sf lot · 1.56 FAR built · Flood zone X
Locations of Work
StructuralMechanicalPlumbing
Floor 318p · 1 filing · 20 docs
Floor 220p · 1 filing · 20 docs
Floor 119p · 1 filing · 20 docs
Cellar24p · 1 filing · 20 docs
Sub-Basement18p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/15/2020$1.7M—Private party → Private party$642/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALL CITY ENGINEERING, P.C.510/02/2023
CELMER ARCHITECTURE PLLC309/28/2023
NTD ENGINEERING CONSULTANT LLC209/28/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
COMMERCIAL CAPITAL USA2003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAPLAN HOME IMPROVEMENT CGeneral Contractor1707/08/2026
ORBIT PLBG & HTG INCPlumbing807/08/2026
DARIUSZ GRYGLEWSKIElectrical103/21/2026
EDWARD BYRNEElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S7010810/02/2023
Building Lifecycle
All (55)Filed (10)Permit Issued (9)Signed Off (3)Inspection (3)Special Inspection (30)
04/17/2025
Signed off — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-S3
03/04/2025
Signed off — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-S1
03/04/2025
Signed off — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-I1
03/28/2024
Permit issued — General Construction
M00696298-I1-GC
02/13/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/17/2024
Permit issued — Plumbing
M00696298-S2-PL
11/08/2023
Permit issued — Structural
M00696298-S1-ST
11/08/2023
Permit issued — General Construction
M00696298-I1-GC
10/02/2023
Filed — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-P7
10/02/2023
Special inspection requirement — Duct leakage testing, insulation and design
XIUCHENG LI
10/02/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
XIUCHENG LI
10/02/2023
Special inspection requirement — Permanent certificate
XIUCHENG LI
10/02/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
10/02/2023
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
10/02/2023
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
10/02/2023
Special inspection requirement — Ventilation and air distribution system
XIUCHENG LI
10/02/2023
Special inspection requirement — Final
XIUCHENG LI
10/02/2023
Special inspection requirement — Mechanical Systems
XIUCHENG LI
10/02/2023
Special inspection requirement — Maintenance information
XIUCHENG LI
10/02/2023
Special inspection requirement — HVAC-R and service water heating equipment
XIUCHENG LI
09/28/2023
Filed — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-P5
09/28/2023
Filed — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-P6
09/28/2023
Special inspection requirement — Structural Steel - Details
XIUCHENG LI
09/28/2023
Special inspection requirement — Fenestration air leakage
XIUCHENG LI
09/28/2023
Special inspection requirement — Concrete - Cast-In-Place
XIUCHENG LI
09/28/2023
Special inspection requirement — Interior lighting power
XIUCHENG LI
09/28/2023
Special inspection requirement — Insulation placement and R values
XIUCHENG LI
09/28/2023
Special inspection requirement — Structural Steel - High Strength Bolting
XIUCHENG LI
09/28/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
XIUCHENG LI
09/28/2023
Special inspection requirement — Fenestration areas
XIUCHENG LI
09/28/2023
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
09/28/2023
Special inspection requirement — Structural Steel - Welding
XIUCHENG LI
09/28/2023
Special inspection requirement — Air barrier - visual inspection
XIUCHENG LI
09/28/2023
Special inspection requirement — Fire-Resistance Rated Construction
XIUCHENG LI
09/28/2023
Special inspection requirement — Final
XIUCHENG LI
09/28/2023
Special inspection requirement — Structural Wood Frame
XIUCHENG LI
09/28/2023
Special inspection requirement — Final
XIUCHENG LI
09/28/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
XIUCHENG LI
09/28/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
09/28/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
XIUCHENG LI
09/28/2023
Special inspection requirement — Preliminary
XIUCHENG LI
03/30/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/28/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/12/2022
Permit issued — Mechanical Systems
M00696298-S3-MS
12/12/2022
Permit issued — Structural
M00696298-S1-ST
12/10/2022
Permit issued — Plumbing
M00696298-S2-PL
12/09/2022
Permit issued — General Construction
M00696298-I1-GC
11/18/2022
Filed — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-P3
11/18/2022
Filed — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-P2
10/14/2022
Filed — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-S3
10/14/2022
Filed — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-S2
10/13/2022
Permit issued — General Construction
M00696298-I1-GC
10/11/2022
Filed — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-S1
09/23/2022
Filed — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-P1
03/14/2022
Filed — Alteration
Related Plumbing work to renovate one family home, including relocation of kitchen to first floor.
M00696298-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offKAPLAN HOME IMPROVEMENT C03/28/2024
DOB NOWPlumbingPermit IssuedORBIT PLBG & HTG INC01/17/2024
DOB NOWStructuralSigned-offKAPLAN HOME IMPROVEMENT C11/08/2023
DOB NOWGeneral ConstructionSigned-offKAPLAN HOME IMPROVEMENT C11/08/2023
DOB NOWMechanical SystemsSigned-offKAPLAN HOME IMPROVEMENT C12/12/2022
DOB NOWStructuralSigned-offKAPLAN HOME IMPROVEMENT C12/12/2022
DOB NOWPlumbingPermit IssuedORBIT PLBG & HTG INC12/10/2022
DOB NOWGeneral ConstructionSigned-offKAPLAN HOME IMPROVEMENT C12/09/2022
DOB NOWGeneral ConstructionSigned-offKAPLAN HOME IMPROVEMENT C10/13/2022
BISOTISSUEDACCORD POWER INC08/29/2023
1 project · most recent 10/02/2023
Heating and Air Conditioning Systems Others Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/02/2023Signed-offKAPLAN HOME IMPROVEMENT CHeating and Air Conditioning Systems, Others, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NAMHZ 54,000 BTU · Condensing Unit ×4
MXZ-SM36NAMHZ 36,000 BTU · Condensing Unit ×2
PUMY-SM60NAM-U1 60,000 BTU · Vrf Outdoor ×2
Ventilation
Greenheck SP-B70 50 CFM · Exhaust Fan ×9
SP-B150 120 CFM · Exhaust Fan ×3
Other
Qmark N/A 6,826 BTU ×1
1 project · most recent 10/02/2023
Gas Water/Sanitary
FiledStatusContractorScope
10/02/2023Permit IssuedORBIT PLBG & HTG INCGas, Water/Sanitary
2 projects · most recent 08/21/2023
General Wiring
FiledStatusContractorScope
08/21/2023CompleteNEWGRANGE ELECTRIC, INC—
12/08/2022Permit IssuedFSM ELECTRICAL CORPORATIOGeneral Wiring
1 project · most recent 10/02/2023
Steel Concrete Wood
FiledStatusContractorScope
10/02/2023Signed-offKAPLAN HOME IMPROVEMENT CSteel, Concrete, Wood
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
02/13/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/30/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/28/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 79
DateRequirementInspectorRole
10/02/2023Duct leakage testing, insulation and designXIUCHENG LIenergy_progress
10/02/2023Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
10/02/2023Energy Code Compliance InspectionsXIUCHENG LIprogress
10/02/2023FinalXIUCHENG LIprogress
10/02/2023HVAC-R and service water piping design and insulationXIUCHENG LIenergy_progress
10/02/2023Permanent certificateXIUCHENG LIenergy_progress
10/02/2023Maintenance informationXIUCHENG LIenergy_progress
10/02/2023HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
10/02/2023Mechanical SystemsXIUCHENG LIspecial
10/02/2023HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
10/02/2023Ventilation and air distribution systemXIUCHENG LIenergy_progress
09/28/2023Fenestration areasXIUCHENG LIenergy_progress
09/28/2023Fenestration and door U-factor and product ratingsXIUCHENG LIenergy_progress
09/28/2023Air barrier - visual inspectionXIUCHENG LIenergy_progress
09/28/2023Insulation placement and R valuesXIUCHENG LIenergy_progress
09/28/2023Interior lighting powerXIUCHENG LIenergy_progress
09/28/2023Fenestration air leakageXIUCHENG LIenergy_progress
09/28/2023PreliminaryXIUCHENG LIprogress
09/28/2023Structural Steel - DetailsXIUCHENG LIspecial
09/28/2023Structural Steel - WeldingXIUCHENG LIspecial
09/28/2023Structural Stability – Alterations of existing buildingsXIUCHENG LIspecial
09/28/2023Structural Steel - High Strength BoltingXIUCHENG LIspecial
09/28/2023Concrete - Cast-In-PlaceXIUCHENG LIspecial
09/28/2023Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
09/28/2023Structural Stability – Alterations of existing buildingsXIUCHENG LIspecial
Latest 25 of 79.
▾Documents — 76 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
09/01/2026M00696298-P6Request digital key ↗
09/01/2026M00696298-P5Request digital key ↗
09/01/2026M00696298-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits2
▸BISWORK PERMIT APPLICATION1
08/29/2023141023489Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
06/07/2023141023489Open ↗
▸Seals & Professional Certifications32
▸DOB NOWProgress Inspector Seal & Signature12
08/27/2026M00696298-P5Open ↗
08/27/2026M00696298-P5Open ↗
08/27/2026M00696298-S2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/13/2026M00696298-S3Open ↗
08/13/2026M00696298-S2Open ↗
08/13/2026M00696298-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/27/2026M00696298-P5Open ↗
08/27/2026M00696298-S2Open ↗
08/27/2026M00696298-P7Open ↗
Showing 3 of 8 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
06/07/2023141023489Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
06/07/2023141023489Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
08/29/2023141023489Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
08/13/2026M00696298-S1Open ↗
08/13/2026M00696298-I1Open ↗
08/13/2026M00696298-S2Open ↗
Showing 3 of 4 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
06/07/2023141023489Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
08/29/2023141023489Open ↗
▸Energy Compliance10
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
09/27/2024141023489Open ↗
09/19/2024141023489Open ↗
08/29/2023141023489Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
09/27/2024141023489Open ↗
09/19/2024141023489Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
10/16/2024141023489Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
06/07/2023141023489Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
06/07/2023141023489Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026M00696298-I1Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
09/27/2024141023489Open ↗
09/19/2024141023489Open ↗
08/29/2023141023489Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
10/16/2024141023489Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/16/2024141023489Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
09/27/2024141023489Open ↗
09/19/2024141023489Open ↗
06/07/2023141023489Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
08/17/2023141023489Open ↗
06/07/2023141023489Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
06/07/2023141023489Open ↗
▸Other Documents3
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026M00696298-P1Open ↗
08/13/2026M00696298-P5Open ↗
08/13/2026M00696298-I1Open ↗