Two family brick
548 PENNSYLVANIA AVENUE
BROOKLYN · East New York-New Lots · BIN 3085061
💬 Discuss this project
1910Year Built
2Stories
B1Building Class
R6Zoning
2,400 sfGross Floor Area
2Units
Rent StabilizedFDNY Report ↗
Two family brick · Owner of record: 548 PENNSYLVANIA DE LLC · 2,383 sf lot · 1.01 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Floor 257p · 1 filing · 20 docs
Floor 157p · 1 filing · 20 docs
Basement61p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WEST ST GARDENS LLC2903/22/2026
AY CONSULTING103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/30/2023$775K—Private party → 548 PENNSYLVANIA LLC$323/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VASILIOS ARTEMIOU PE706/04/2024
LEANDRO NILS DICKSON ARCHITECT, LLC304/18/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC2003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JSB WORKS INCGeneral Contractor603/21/2026
POWER DIRECT ELECTRIC INCElectrical103/22/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
KISHAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616706/04/2024
Building Lifecycle
All (112)Filed (10)Permit Issued (4)Signed Off (3)Inspection (11)Objection (54)Special Inspection (30)
09/05/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/28/2024
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00880249-I1
B00880249-S1
08/28/2024
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00880249-I1
B00880249-S2
08/14/2024
Inspection — Pass-Final SP - Up to 3 Requested Floors
Pass
View inspection ↗
07/15/2024
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
07/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
07/15/2024
Special inspection requirement — Sprinkler Systems
FAHAD FATEH
06/18/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/11/2024
Objection raised — Admin
06/11/2024
Objection resolved — Addressed
06/07/2024
Special inspection requirement — Maintenance information
FAHAD FATEH
06/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
06/07/2024
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
06/07/2024
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
06/07/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
06/04/2024
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00880249-I1
B00880249-P6
05/30/2024
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00880249-I1
B00880249-P5
05/27/2024
Special inspection requirement — Sprinkler Systems
FAHAD FATEH
05/27/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
05/27/2024
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
05/13/2024
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00880249-I1
B00880249-S3
04/26/2024
Inspection — Pass-Final SP - Up to 3 Requested Floors
Pass
View inspection ↗
04/18/2024
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00880249-I1
B00880249-P4
04/18/2024
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
04/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
04/18/2024
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
04/18/2024
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
04/18/2024
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
04/18/2024
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
04/18/2024
Special inspection requirement — Permanent certificate
FAHAD FATEH
04/18/2024
Special inspection requirement — Metering
FAHAD FATEH
04/18/2024
Special inspection requirement — Interior lighting power
FAHAD FATEH
04/18/2024
Special inspection requirement — Maintenance information
FAHAD FATEH
04/18/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
04/18/2024
Special inspection requirement — Fenestration areas
FAHAD FATEH
04/15/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/28/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/20/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/20/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/30/2024
Permit issued — Mechanical Systems
B00880249-S3-MS
01/29/2024
Permit issued — Sprinklers
B00880249-S2-EW-SP
01/23/2024
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
01/09/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
01/09/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/22/2023
Permit issued — Plumbing
B00880249-S1-PL
12/21/2023
Permit issued — General Construction
B00880249-I1-GC
12/21/2023
Objection resolved — Addressed
12/21/2023
Objection resolved — Addressed
12/20/2023
Objection raised — Scope
12/20/2023
Objection raised — Energy
12/15/2023
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00880249-I1
B00880249-P2
12/15/2023
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00880249-I1
B00880249-P3
12/14/2023
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00880249-I1
B00880249-P1
12/14/2023
Objection resolved — Addressed
12/14/2023
Special inspection requirement — Duct leakage testing, insulation and design
12/14/2023
Special inspection requirement — HVAC-R and service water heating system controls
12/14/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
12/14/2023
Special inspection requirement — Ventilation and air distribution system
12/14/2023
Special inspection requirement — HVAC-R and service water heating equipment
12/14/2023
Special inspection requirement — Final
Latest 60 of 112 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offJSB WORKS INC01/30/2024
DOB NOWSprinklersSigned-offA M B MECHANICAL INC01/29/2024
DOB NOWPlumbingSigned-offN AND S PLUMBING INC12/22/2023
DOB NOWGeneral ConstructionPermit IssuedJSB WORKS INC12/21/2023
1 project · most recent 06/04/2024
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/04/2024Signed-offJSB WORKS INCHeating and Air Conditioning Systems
Heat / Cool
Daikin RXS12BXVJU 14,400 BTU · Condensing Unit ×7
RXS18BXVJU 18,300 BTU · Condensing Unit ×2
3MXS24WMVJU9 24,000 BTU · Condensing Unit ×1
RXS12LVJU 14,400 BTU · Condensing Unit ×7
RXS15LVJU 18,300 BTU · Condensing Unit ×2
3MXS24NMVJU 24,000 BTU · Condensing Unit ×1
1 project · most recent 06/04/2024
Sprinkler System
FiledStatusContractorScope
06/04/2024Signed-offPRIME PIPING & HEATING INSprinkler System
1 project · most recent 06/04/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
06/04/2024Signed-offKISHAN PLUMBING INCGas, Storm, Water/Sanitary
2 projects · most recent 07/22/2024
General Wiring
FiledStatusContractorScope
07/22/2024CompletePOWER DIRECT ELECTRIC INCGeneral Wiring
01/02/2024CompletePOWER DIRECT ELECTRIC INC—
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
09/05/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/14/2024Pass-Final SP - Up to 3 Requested FloorsPassView ↗
06/18/2024Pass-Final CND-Occupancy InspectionPassView ↗
04/26/2024Pass-Final SP - Up to 3 Requested FloorsPassView ↗
04/15/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/28/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/20/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/20/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/23/2024Pass-Final PL - Up to 9 Requested FloorsPassView ↗
01/09/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/09/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
07/15/2024Post-installed AnchorsFAHAD FATEHspecial
07/15/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
07/15/2024Sprinkler SystemsFAHAD FATEHspecial
06/07/2024Maintenance informationFAHAD FATEHenergy_progress
06/07/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
06/07/2024HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
06/07/2024HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
06/07/2024HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
05/27/2024Sprinkler SystemsFAHAD FATEHspecial
05/27/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
05/27/2024Post-installed AnchorsFAHAD FATEHspecial
04/18/2024Fenestration air leakageFAHAD FATEHenergy_progress
04/18/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
04/18/2024Energy Code Compliance InspectionsFAHAD FATEHprogress
04/18/2024Fire-Resistance Rated ConstructionFAHAD FATEHprogress
04/18/2024Air barrier - visual inspectionFAHAD FATEHenergy_progress
04/18/2024Insulation placement and R valuesFAHAD FATEHenergy_progress
04/18/2024Permanent certificateFAHAD FATEHenergy_progress
04/18/2024MeteringFAHAD FATEHenergy_progress
04/18/2024Interior lighting powerFAHAD FATEHenergy_progress
04/18/2024Maintenance informationFAHAD FATEHenergy_progress
04/18/2024Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
04/18/2024Fenestration areasFAHAD FATEHenergy_progress
12/14/2023Duct leakage testing, insulation and design—energy_progress
12/14/2023HVAC-R and service water heating system controls—energy_progress
Latest 25 of 32.
▾Documents — 44 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/26/2026B00880249-S3Request digital key ↗
08/26/2026B00880249-S2Request digital key ↗
08/26/2026B00880249-S1Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00880249-I1Open ↗
▸Seals & Professional Certifications17
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/26/2026B00880249-S3Open ↗
08/26/2026B00880249-S2Open ↗
08/26/2026B00880249-S1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/28/2026B00880249-S2Open ↗
08/25/2026B00880249-S1Open ↗
08/23/2026B00880249-P4Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026B00880249-S1Open ↗
08/23/2026B00880249-P4Open ↗
08/23/2026B00880249-P4Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/13/2026B00880249-P1Open ↗
08/13/2026B00880249-P4Open ↗
08/13/2026B00880249-I1Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/26/2026B00880249-S3Open ↗
08/26/2026B00880249-S2Open ↗
08/26/2026B00880249-S1Open ↗
Showing 3 of 10 on file for this type
▸Other Documents3
▸DOB NOWProperty Ownership Certification3
08/26/2026B00880249-I1Open ↗
08/26/2026B00880249-P4Open ↗
08/26/2026B00880249-P1Open ↗