← Back
Primarily 2 family with 1 store or office
549 METROPOLITAN AVENUE
BROOKLYN · BIN 3068659
💬 Discuss this project
1920Year Built
3Stories
S2Building Class
R7AZoning
3,530 sfGross Floor Area
3Units
3 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: JI SHUNG INC · 1,613 sf lot · 2.19 FAR built · Flood zone X
Locations of Work
Structural
Cellar1p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
549 METRO1003/21/2026
TABLE FOR 8103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/22/2025$2.8M—549 METRO CORP. → JI SHUNG INC$786/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JUST CONSULTING ENGINEERING103/15/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DOMINICK SIANO G'NL CONTGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JUST CONSULTING ENGINEERI5865103/15/2025
Building Lifecycle
All (12)Filed (1)Permit Issued (1)Signed Off (1)Violation (6)Special Inspection (3)
04/11/2025
Signed off — Alteration
REPLACE TEMPORARY JACK POSTS WITH PERMANENT STEEL POSTS AT EXACT SAME LOCATIONS ON EXISTING FOOTING ON THE CELLAR FLOOR. NO CHANGE OF EGRESS AND USAGE.
B01194026-I1
04/03/2025
Permit issued — Structural
B01194026-I1-ST
03/15/2025
Filed — Alteration
REPLACE TEMPORARY JACK POSTS WITH PERMANENT STEEL POSTS AT EXACT SAME LOCATIONS ON EXISTING FOOTING ON THE CELLAR FLOOR. NO CHANGE OF EGRESS AND USAGE.
B01194026-I1
03/12/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
XIAOJUN WANG
03/12/2025
Special inspection requirement — Structural Steel - Details
XIAOJUN WANG
03/12/2025
Special inspection requirement — Final
CALVIN TRAN
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/23/2011
Violation issued (ECB, closed)
Unknown
03/23/2011
Violation issued (ECB, closed)
Construction
09/09/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offDOMINICK SIANO G'NL CONT04/03/2025
BISOTISSUEDBEYOND BUILDING INC06/10/2019
BISPLISSUEDZONE PLUMBING & HEATING C06/10/2019
BISPLISSUEDLOSPANO PLBG & HTG INC01/22/2013
BISOTISSUEDDOMINICK SIANO G'NL CONT01/17/2013
BISEQISSUEDDOMINICK SIANO G'NL CONT11/30/2012
BISOTISSUEDDOMINICK SIANO G'NL CONT11/30/2012
BISMHISSUEDSK ONE CONSTRUCTION INC09/25/2012
BIS—ISSUEDEZ RUNER CONSTRUCTION COR05/02/2012
BISEQISSUEDARSENAL SCAFFOLD INC03/27/2012
BISEQISSUEDARSENAL SCAFFOLD INC03/27/2012
BISFPISSUEDMASTER FIRE SYSTEMS, INC09/30/2009
BISMHISSUEDHENG YIP CONSTRUCTION COR08/21/2009
BISOTISSUEDHENG YIP CONSTRUCTION COR07/10/2009
BISFPISSUEDNEW YORK BUSINESS FIRE SYSTEM06/01/2005
BISOTISSUED55C_CONST CORP04/26/2005
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
03/12/2025Structural Stability – Alterations of existing buildingsXIAOJUN WANGspecial
03/12/2025Structural Steel - DetailsXIAOJUN WANGspecial
03/12/2025FinalCALVIN TRANprogress
▾Documents — 161 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026B01194026-I1Request digital key ↗
▸Applications & Permits34
▸BISPLAN / WORK APPROVAL APPLICATION16
09/10/2019321964825Open ↗
06/11/2019321964825Open ↗
06/20/2013320693558Open ↗
Showing 3 of 16 on file for this type
▸BISWORK PERMIT APPLICATION15
06/11/2019321964825Open ↗
06/11/2019321964825Open ↗
01/23/2013320693558Open ↗
Showing 3 of 15 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION2
08/27/2019321964825Open ↗
08/27/2019321964825Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
02/06/2013320382439Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISZoning Diagram (ZD1)1
09/21/2012320382439Open ↗
▸Seals & Professional Certifications29
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION16
06/11/2019321964825Open ↗
12/14/2012320453399Open ↗
12/14/2012320453914Open ↗
Showing 3 of 16 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
06/11/2019321964825Open ↗
01/08/2013320693558Open ↗
08/22/2012320537834Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
01/08/2013320693558Open ↗
08/16/2012320537834Open ↗
03/29/2012320453914Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/11/2019321964825Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/22/2026B01194026-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/28/2026B01194026-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026B01194026-I1Open ↗
▸Trade Schedules & Equipment12
▸BISSCHEDULE B - PLUMBING5
06/20/2013320693558Open ↗
01/08/2013320693558Open ↗
07/30/2009320026814Open ↗
Showing 3 of 5 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT3
10/21/2011320382046Open ↗
11/20/2009320026814Open ↗
03/11/2013320382046Open ↗
▸BISEQUIPMENT USE PERMITS1
11/19/2009320026814Open ↗
▸BISRPZ/DDCV TEST REPORT : GEN215B1
10/27/2012320382439Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
06/11/2019321964825Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
10/29/2009320026814Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST2
08/16/2012320537834Open ↗
10/24/2011320382439Open ↗
▸BISST-1 Street Tree Checklist1
01/08/2013320693558Open ↗
▸BISTenant Protection Plan and Notes1
06/11/2019321964825Open ↗
▸Environmental & Asbestos14
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'8
03/29/2012320453914Open ↗
10/24/2011320382439Open ↗
10/21/2011320382046Open ↗
Showing 3 of 8 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)3
01/08/2013320693558Open ↗
01/08/2013320693558Open ↗
01/08/2013320693558Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
06/11/2019321964825Open ↗
01/18/2013320693558Open ↗
08/16/2012320537834Open ↗
▸Energy Compliance9
▸BISTR8: Energy Code Progress Inspections3
04/08/2013320537834Open ↗
03/11/2013320382046Open ↗
01/08/2013320693558Open ↗
▸BISEN2 - As Built Energy Analysis3
11/25/2013320382439Open ↗
03/11/2013320382046Open ↗
10/17/2013320693558Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
06/11/2019321964825Open ↗
08/16/2012320537834Open ↗
▸BISTECHNICAL REPORT: ENERGY1
10/21/2011320382046Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX2
11/25/2013320382439Open ↗
11/25/2013320382439Open ↗
▸BISTECHNICAL REPORT: CONCRETE-TEST CYLINDER2
11/25/2013320382439Open ↗
11/25/2013320382439Open ↗
▸Approvals, Objections & Sign-offs20
▸BISADMINISTRATIVE OBJECTIONS8
08/17/2012320537834Open ↗
03/30/2012320453914Open ↗
03/27/2012320453399Open ↗
Showing 3 of 8 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
04/16/2013320069527Open ↗
02/26/2013320069527Open ↗
12/14/2012320453399Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE3
04/04/2012320382439Open ↗
10/24/2011320382439Open ↗
05/02/2012320382439Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
11/25/2013320382439Open ↗
▸BISThird Party Electrical Signoff Compliance Report1
10/17/2013320693558Open ↗
▸Cost, Insurance & Ownership15
▸BISCOST AFFIDAVIT15
06/11/2019321964825Open ↗
11/25/2013320382439Open ↗
10/17/2013320693558Open ↗
Showing 3 of 15 on file for this type
▸Filing & Intake Forms16
▸BISADDITIONAL INFORMATION8
09/10/2019321964825Open ↗
08/15/2019321964825Open ↗
11/25/2013320382439Open ↗
Showing 3 of 8 on file for this type
▸BISEFILING COVER SHEET8
06/13/2019321964825Open ↗
01/07/2013320693558Open ↗
08/16/2012320537834Open ↗
Showing 3 of 8 on file for this type
▸Other Documents2
▸BISFIRE SUPP ANSUL APPROVL- FD-FSS1
02/26/2013320069527Open ↗
▸BISPLOT DIAGRAM1
10/24/2011320382439Open ↗