← Back
Elevator cooperative
55-30 98 PLACE
QUEENS · BIN 4431633
💬 Discuss this project
1964Year Built
6Stories
D4Building Class
R7BZoning
149,548 sfGross Floor Area
138Units
LL97 CoveredRent Stabilized8 Open Violations 7 unresolved · 1 paperwork only ▸FISP: SAFEFDNY Report ↗
Elevator cooperative · 51,019 sf lot · 2.93 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Roof8p · 2 filings · 20 docs
Bulkhead2p · 1 filing · 20 docs
Floor 76p · 1 filing · 20 docs
Floor 66p · 1 filing · 20 docs
Floor 57p · 1 filing · 20 docs
Floor 46p · 1 filing · 20 docs
Floor 36p · 1 filing · 20 docs
Floor 26p · 1 filing · 20 docs
Floor 17p · 1 filing · 20 docs
Cellar20p · 3 filings · 20 docs
1 job · most recent 11/07/2022
Associated Ducts and Piping
FiledStatusContractorScopeMake / Model / Capacity
11/07/2022Permit IssuedLXS AIR INCAssociated Ducts and Piping
Ducts & Piping
Juniper Elbow P0630 - 6” 1,200 CFM · Ductwork ×3
1 job · most recent 11/07/2022
FiledStatusContractorScope
11/07/2022Permit IssuedADVANCED PLBG, MECH & SPR—
1 job · most recent 11/07/2022
Gas Water/Sanitary
FiledStatusContractorScope
11/07/2022Permit IssuedADVANCED PLUMBING MECHGas, Water/Sanitary
2 jobs · most recent 08/11/2026
General Wiring
FiledStatusContractorScope
08/11/2026Permit IssuedDENALI ELECTRIC CORPGeneral Wiring
12/05/2024Permit IssuedNET POWER ELECTRIC CORPGeneral Wiring
Building Lifecycle
All (92)Filed (5)Permit Issued (4)Signed Off (1)Facade (FISP) (12)Violation (50)Inspection (7)Special Inspection (13)
06/24/2026
Violation issued (ECB, open)
Elevators
12/04/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/04/2025
Inspection — Pass-Final SP - Up to 3 Requested Floors
Pass
View inspection ↗
11/25/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/20/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/06/2025
Filed — New Building
Foundation, excavation and SOE filed in conjunction to new building application #Q01034910-I1.
Q01034910-P2
10/06/2025
Filed — New Building
Foundation, excavation and SOE filed in conjunction to new building application #Q01034910-I1.
Q01034910-P3
10/06/2025
Special inspection requirement — Concrete - Cast-In-Place
10/06/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
10/06/2025
Special inspection requirement — Final
10/06/2025
Special inspection requirement — Concrete - Cast-In-Place
10/06/2025
Special inspection requirement — Deep Foundation Elements
10/06/2025
Special inspection requirement — Subgrade Inspections
10/06/2025
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
10/06/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
10/06/2025
Special inspection requirement — Final
10/06/2025
Special inspection requirement — Footing and Foundation
06/27/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
06/25/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/20/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/07/2025
Permit issued — Plumbing
Q08034422-I1-PL
04/04/2025
Permit issued — Mechanical Systems
Q08034423-I1-MS
04/04/2025
Permit issued — Sprinklers
Q08034422-I1-EW-SP
11/23/2023
Violation issued (HPD, closed)
B
11/23/2023
Violation issued (HPD, closed)
B
11/23/2023
Violation issued (HPD, closed)
B
11/23/2023
Violation issued (HPD, closed)
B
11/23/2023
Violation issued (HPD, closed)
C
11/23/2023
Violation issued (HPD, closed)
A
11/23/2023
Violation issued (HPD, closed)
B
11/30/2022
Violation issued (ECB, closed)
Construction
11/07/2022
Filed — Alteration
FILING HEREWITH DRAWINGS TO INSTALL NEW EXHAUST DUCTS FOR PROPOSED GAS DRYERS. THIS APPLICATION DOES NOT REQUIRE A NEW OR AMENDED CERTIFICATE OF OCCUPANCY AS THERE IS NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q08034423-I1
11/07/2022
Filed — Alteration
HEREBY FILING THIS APPLICATION TO PROPOSE A NEW LAUNDRY ROOM LOCATED IN THE CELLAR AS AN ACCESSORY USE TO THE BUILDING AS PER PLANS SUBMITTED. THIS APP DOES NOT REQUIRE A NEW OR AMENDED CERT. OF OCCUPANCY AS THERE IS NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q08034422-I1
11/07/2022
Special inspection requirement — Tenant Protection Plan Compliance
Alexander Bomstein
11/04/2022
Special inspection requirement — Mechanical Systems
Alexander Bomstein
11/04/2022
Special inspection requirement — Final
ROMAN MARDAREWICH
09/21/2022
Signed off — Alteration
Q00776045-I1
08/19/2022
Permit issued — General Construction
Q00776045-I1-GC
07/25/2022
Filed — Alteration
Q00776045-I1
07/02/2022
Cycle 9 facade report submitted
07/02/2022
Cycle 9 facade report signed — SAFE
06/07/2022
Cycle 9 facade inspection completed
01/24/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/24/2022
Violation issued (ECB, closed)
Construction
03/17/2020
Violation issued (ECB, closed)
Elevators
09/06/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/03/2019
Violation issued (HPD, closed)
C
08/20/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/14/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/13/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
07/12/2016
Violation issued (ECB, closed)
Elevators
06/28/2016
Cycle 8 facade report submitted
06/23/2016
Cycle 8 facade report signed — SAFE
06/20/2016
Cycle 8 facade inspection completed
10/15/2015
Violation issued (HPD, closed)
I
05/26/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/27/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/16/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/17/2012
Violation issued (HPD, closed)
A
08/17/2012
Violation issued (HPD, closed)
C
Latest 60 of 92 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CENTRAL QUEENS PROPERTIES1504/09/2026
SHERWOOD VILLAGE OWNERS1403/22/2026
SHERWOOD VILLAGE COOP103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
R & O ENGINEERING210/06/2025
ROMAN S. MARDAREWICH ARCHITECT211/07/2022
STRUCTURAL ENGINEERING BURO107/25/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SKY MANAGEMENT GROUP403/21/2026
PWF303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RAPID MASONRY RESTORATION CORPGeneral Contractor203/21/2026
ADVANCED PLBG, MECH & SPRFire Protection106/28/2026
LXS AIR INCGeneral Contractor104/09/2026
ADVANCED PLUMBING MECHPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A&B WORLD CONSULTING, INC5704211/07/2022
STRUCTURAL ENGINEERING BU5883107/25/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedADVANCED PLUMBING MECH04/07/2025
DOB NOWMechanical SystemsPermit IssuedLXS AIR INC04/04/2025
DOB NOWSprinklersPermit IssuedADVANCED PLBG, MECH & SPR04/04/2025
DOB NOWGeneral ConstructionSigned-offPIOTR POTOCKI08/19/2022
BISFSISSUEDACE ATLAS CORP01/18/2017
BISPLISSUEDGMAK PLMBG AND HEATNG LLC01/22/2007
BISFBISSUEDLEONARD R. SIBBRIZZI01/18/2007
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
12/04/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/04/2025Pass-Final SP - Up to 3 Requested FloorsPassView ↗
11/25/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/20/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/27/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
06/25/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/20/2025Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
10/06/2025Concrete - Cast-In-Place—special
10/06/2025Structural Stability – Alterations of existing buildings—special
10/06/2025Final—progress
10/06/2025Concrete - Cast-In-Place—special
10/06/2025Deep Foundation Elements—special
10/06/2025Subgrade Inspections—special
10/06/2025Subsurface Conditions – Fill Placement & In-Place Density—special
10/06/2025Subsurface Investigations (Borings/Test Pits)—special
10/06/2025Final—progress
10/06/2025Footing and Foundation—progress
11/07/2022Tenant Protection Plan ComplianceAlexander Bomsteinspecial
11/04/2022Mechanical SystemsAlexander Bomsteinspecial
11/04/2022FinalROMAN MARDAREWICHprogress
▾Documents — 53 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/26/2026Q00776045-I1Contact architect ↗
08/25/2026Q08034423-I1Contact architect ↗
08/25/2026Q08034422-I1Contact architect ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION5
06/03/2025421841118Open ↗
05/21/2025421841118Open ↗
11/15/2024421841118Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION1
01/13/2017440377281Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
11/19/2024421841118Open ↗
▸BISTAX LOT: FINAL LOT NUMBER ISSUED1
10/23/2025421841118Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
11/19/2024421841118Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
11/19/2024421841118Open ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/26/2026Q00776045-I1Open ↗
08/25/2026Q08034423-I1Open ↗
08/13/2026Q08034422-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
01/13/2017440377281Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
01/13/2017440377281Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
04/13/2017440377281Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
01/13/2017440377281Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/28/2026Q08034423-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026Q08034423-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
01/13/2017440377281Open ↗
▸Safety & Tenant Protection2
▸BISTENANT PROTECTION PLAN AND NOTES1
01/13/2017440377281Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q01034910-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/26/2026Q00776045-I1Open ↗
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT5
08/13/2026Q01034910-S5Open ↗
08/13/2026Q01034910-I1Open ↗
08/13/2026Q01034910-P3Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY1
01/13/2017440377281Open ↗
▸Approvals, Objections & Sign-offs9
▸BISLETTERS - SUPPORTING DOCUMENTATION7
10/23/2025421841118Open ↗
10/23/2025421841118Open ↗
06/03/2025421841118Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE1
10/24/2025421841118Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
04/13/2017440377281Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
04/13/2017440377281Open ↗
01/13/2017440377281Open ↗
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET2
06/03/2025421841118Open ↗
05/21/2025421841118Open ↗
▸BISADDITIONAL INFORMATION2
10/24/2025421841118Open ↗
10/24/2025421841118Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
01/13/2017440377281Open ↗
▸Other Documents5
▸BISPLOT DIAGRAM4
10/24/2025421841118Open ↗
10/23/2025421841118Open ↗
10/23/2025421841118Open ↗
Showing 3 of 4 on file for this type
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
10/24/2025421841118Open ↗