ECB05/16/2025FAILED TO COMPLY WITH SWO ISSUED ON 01/04/22. OBSERVED WORK WAS COMPLETED & PERMIT #340577085 EXPIRED ON 03/31/22 & WAS NEVER RENEWED., COMPLY WITH STOP WORK ORDER$10K due
ECB05/16/2025FAILED TO CERTIFY CORRECTION FOR SUMMONS #39130025P., FILE A CERTIFICATE OF CORRECTION$1K due
ECB05/16/2025FAILED TO COMPLY W/ COMMISSIONERS ORDERS FOR SUMMONS TO OBTAIN FENCE PERMIT FOR SUMMONS #35593127L., COMPLY WITH COMMISSIONER'S ORDER$12K due
DOB01/22/2025FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB11/12/2024OBSERVED WORKER INSTALLING A CHAIN LINK FENCE AT ROOF LEVEL PARAPET EXPOSURE #1., OBTAIN PERMIT; STOP ALL WORK ROOF LEVEL. MAKE SITE SAFE. OBTAIN PERMIT.$2K due
DOB06/30/2022THE ADJACENT CONSTRUCTION SITE CAUSED CRACKS INSIDE TO THE EXPOSURE 4 SIDE OF THE PREMISE RENDERING THE PREMISE NON-COMPLIANT
DOB03/30/2022FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB01/13/2022WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS.STOP ALL FACADE WORK AT EXP #1 SUBMITED DRAWINGS DO NOT SHOW ALL OPENINGS AND CLOSURES OF WINDOWS AND DOORS.DOES NOT SHOW EXTENT OF PROPOSED WORK.MISSING$6K due
ECB01/11/2022TEMP CONST EQUIPMENT ONSITE W/EXPIRED PERMIT NOTE:ATO MY INSP OF 1STYBUNDER ALT UNDER CONST INACTIVE JOBSITE.I OBSERVED ERECTED SWS ALONG BLDG EXP2 W/REV OF DEPT RECORDS WHICH REVEALED PERMIT FOR SWS EXPIRED ON$6K due
ECB01/06/2022PEDESTRIAN PROTECTION NOT MEET CODE SPECS.SWS ATOI ON ACTIVE 1STY FACADE REPLACE BUILT UP ROOFING&ROOF JOISTS PERMIT SITE THATS OCCUPIED.I OBSERVED SWS IN PLACE@EXP2 E8ST LIGHTS UNDERNEATH DECK NOT ON TO PROVID$10K due
ECB01/04/2022FAILURE TO SAFEGUARD ALL PERSONS AN PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.AT EXPOSURE 1/STEEL SHORING AND BRICK WORK, OPEN & EXPOSED TO PUBLIC.NO JOBSITE FENCE PROVIDED AT THIS LOCATION.REMEDY:STOP WORK$25K due
DOB12/11/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB09/12/2019REFERENCE TO DOB RECORDS PREMISES HAS FULL VACATE ORDER IN EFFECT ISSUED ON 12/15/2017. HOWEVER, AT TIME OF INSPECTION, OBSERVED FULLY FUNCTIONING HORSE STABLE WITH APPROXIMATELY 10 HORSES, TRAINING EQUIPMENT,$6K due
DOB06/22/2018V-DOB VIOLATION - ACTIVE
DOB05/11/2018COMPLY WITH VACATE
DOB03/07/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/08/2018EMERG WRK.ROOF HAS PART COLL AT FRONT OF BLDG.ROOFING MEMBRANE IN DISREPAIR AT ROOF&INADEQ COVERED.WATER LEAKING INSIDE BLDG.REMEDY:OWN IMMED ENGAGE NYS PROF ENG&CONT'R TO SHORE THE ROOF.SHORING WORK TO BE CONT SUPERV OF A PE. FILING TO SHORING TO BE DONE W/2 BUS DAYS OF COMMENCEMENT OF WORK
DOB12/19/2017FTM BLDG.ROOF HAS PART COLL FOR AN AREA AT FRONT OF BLDG.ROOFING MEMBRANE IS IN DISREPAIR AT APPROX 80% OF THE ROOF&INADEQUATELY COVER W/TARPS.WATER IS LEAKING INSIDE BLDG.REMEDY:OWN ENGAGE NYS PROF ENG EVAL BLDG.PERM FOR REPAIR JOB TO BE OBTAIN NO LATER 1/15/18.SIGN OFF OF REPAIR JOB TO BE NO LATER THAN 3/15/18
DOB03/08/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/24/2014FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB05/22/2001V-DOB VIOLATION - ACTIVE
DOB07/10/2000HAZARDOUS
DOB06/30/2000HAZARDOUS
ECB11/17/2025AT TIME OF INSPECTION OBSERVED STOP WORK ORDER STICKER HAS BEEN REMOVED. ECB VIOLATION # 39130025P ISUUED ON 11/12/24 .NO LONGER POSTED AT LOCATION., COMPLY WITH CODEHearing held — result not yet published$5K proposed
ECB06/03/2023FAILURE TO RENEW SIDEWALK SHED PERMIT. OBSERVED SIDEWALK SHED IN PLACE WITH EXPIRED PERMIT IN CONTRARY WITH CODES. PERMIT # B00111851-I1-SH, EXPIRES 07/22/2022Nothing owed — awaiting certificate of correction
ECB02/15/2023TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT.AT TIME OF INSPECTION OBSERVED 1 STORY BUILDING WITH SIDEWALK SHED ERECTED AT EXP #2 UPON RESEARCH PERMIT #B00111851-I1-SH IN DOB NOW EXPIRED 7/22/22 CODENothing owed — awaiting certificate of correction
ECB12/15/2017FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.@ TIME OF INSPECTION OBSERVED 1 STORY BUILDING WITH A COMPROMISE ROOF LOCATED AT THE SOUTH EAST CORNER OF THE ROOF.NOTED:THE WEST PARAPET WALL IS SLIGHTLY PNothing owed — awaiting certificate of correction
ECB12/05/2016FAILURE TO MAINTAIN EXTERIOR WALLS OR APPURTENANCES. NOTED: AT THE TIME OF MY INSPECTION,I OBSERVED MINOR CRACKS & MOVEMENT AT EXTERIOR MASONRY WALL AT EXP#2(EAST 8 ST). ROOF IN A STATE OF DISREPAIR(NOT WATERNothing owed — awaiting certificate of correction
ECB04/18/2016FAIL TO MAINTIAN BLDG CODE-COMPLAINT MANNER WOOD GHEATHING ON ROOF, ROTTED & IN STATE OF DISREPAIR AT VARIOUS LOCATIONS & HANGING DOWN. REMEDY: REPAIR / & OR / REPLACENothing owed — awaiting certificate of correction
ECB06/27/2014FAILURE TO MAINTIAN BLDG WALLS OR APPURTENANCES. NOTED @ EXTERIOR FACADE EXP.2 VARIOUS CRACKS THROUGHOUT,DETERIORATED MORTAR JOINTS AS WELL AS PARAPET LEVEL BULGINING APPROX.6' OUTWARD.ALONG INTERIOR EXP.1 WHERNothing owed — awaiting certificate of correction
ECB04/22/2010FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. STRUCTURE OCCUPIED AS (HOIST) STABLE IN FL IN POOR CONDITION CORRODED WOOD BEAMS, MISSINGFIRE STOPPING THROUHGOUT ENTIRE STRUCTURE, WARPED WOOD SECTIONS ONNothing owed — awaiting certificate of correction
ECB04/13/2006FAILURE TO PROVIDE FILE STOPPING WHERE REQUIRED:NOTED:EXPOSED WOOD BEAMS AND JOISTS THROUGHOUT THE PROPERTY. AT CEILING AREAS;ALSO NOTED:OPENING AND BROKEN SEAL AROUND SKYLIGHT, WHICH LET THE RAIN WATERNothing owed — awaiting certificate of correction
ECB01/10/2006WORK W/O A PERMIT. WORK NOTED: REPLACE APPROX. 100 WOOD JOIST AT CEILING. REMEDY: OBTAIN PERMIT IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB06/29/2004FAILURE TO MAINTAIN: DEFECT NOTED-(1)STEEL LINTELS ARE DETERIORATED CAUSING VERTICAL, HORIZONTAL & DIAGONAL STRESS CRACKS IN BRICK. (2)MISSING SPALLING BRICK, COPING STONES & MASONY JOINTS AT PARAPET WALL THROUNothing owed — awaiting certificate of correction
ECB05/11/2004FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING NOTED:A PILE OF DEBRIS CONSIST OF BRICKS AND OLD MATTERS NOW STORED AT BLDG WEST SIDE AND PUBLIC SIDEWALK NO PROTECTION PROVIDED.REMEDY:MAINTAIN ADEQAUTE HOUSEKEEPINGNothing owed — awaiting certificate of correction
ECB05/11/2004WORK WITHOUT A PERMIT WORK NOTED DEMOLITION IN PROGRESS AT BUILDING WEST SIDE FACADE AS FOLLOWS (1) REMOVED EXISTING COPING STONES THROUGHOUT PARAPET FRONT AND WEST SIDES AT ROOF (2) REMOVED SECTION OF EXISTINGNothing owed — awaiting certificate of correction
ECB03/17/2004FAILURE TO MAINTAIN EXTERIOR BLDG WALL:DIAGONAL CRACKS AND LOOSE BRICKS AT WINDOW LOCATION AT WEST FACADE (2)UNKEY MORTAR JOINTS THROUGHOUT COPING STONES AT ROOF PARAPET FRONT AND WEST SIDES (3)ERODED STEEL ATNothing owed — awaiting certificate of correction
ECB03/17/2004FAILURE TO MAINTAIN :NOTED:BULGING IN CEILING BELOW TRAY LOFT (2)CEILING LOOSE AND PART MISSING IN ROOM BEING USED AS OFFICE (3)OPENING AT ROOF,EAST (4)WATER LEAKING FROM ROOF AT CENTER SECTION WEST (5)MISSINGNothing owed — awaiting certificate of correction
ECB05/22/2001FAILURE TO MAINTAIN BUILDING. DEFECTS PARTIAL COLLAPSED CORNICE AT ROOF LEVEL AN SOUTH AND EAST PERIMETER. REMEDY: MAINTAIN BUILDING.Nothing owed — awaiting certificate of correction
ECB07/10/2000FIALURE TO MAINTAIN NOTE AT REAR OF STABLE A 25' MAIN GIRDER HAS A 6" SAG AND IN POSSIBLE DANGER OF COLLASPSING NOTED: AT ROOF LEVEL AN SOUTH & EAST PERIMETER MISSING COPEING AS WELL AS FA PARTIAL COLLASPE OFNothing owed — awaiting certificate of correction