← Back
Predominantly retail with other uses
55 EAST BROADWAY
MANHATTAN · BIN 1003416
💬 Discuss this project
1900Year Built
3Stories
K4Building Class
C6-1GZoning
5,625 sfGross Floor Area
3Units
2 Open Violations ▸FDNY Report ↗
Predominantly retail with other uses · Owner of record: 55 EAST BROADWAY REALTY LLC · 1,875 sf lot · 3 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction3p · 3 filings · 20 docs
Floor 3Under Construction9p · 4 filings · 20 docs
Floor 2Under Construction26p · 4 filings · 20 docs
Floor 1Under Construction25p · 4 filings · 20 docs
CellarUnder Construction45p · 8 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
55 EAST BROADWAY REALTY5209/13/2026
KHOWONG REALTY903/22/2026
OWNER OF 55 EAST BROAD103/22/2026
THE OWNER OF103/22/2026
KNOWONG REALTY CORP C/O D103/22/2026
78 WEDDING CENTER203/21/2026
100 DIVIDSION STREET103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/27/2023$3.9M—KHOWONG REALTY CORP. → 55 EAST BROADWAY REALTY LLC$693/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALL CITY ENGINEERING PC607/10/2026
TLI ARCHITECT, PLLC1209/03/2025
WELLWORTH CONSULTING LLC109/13/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING603/21/2026
UNITED SAFETY CONSULTANTS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MCNY CONTRACTING LLCGeneral Contractor1007/08/2026
BEYOND COOLING LLCGeneral Contractor407/29/2026
RRP PLUMBING CORPPlumbing207/08/2026
RRP PLUMBING CORPFire Protection107/29/2026
UNITED ELEC'L CONT'G CORPElectrical103/22/2026
SPRING SCAFFOLDING LLCGeneral Contractor107/08/2026
MPS PLUMBING & HEATING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JD ENGINEERING PC9859507/10/2026
ALL CITY ENGINEERING PC7115112/10/2025
MW PROFESSIONAL ENGINEERI570405/21/2025
Building Lifecycle
All (122)Filed (19)Permit Issued (13)Signed Off (3)Violation (19)Inspection (7)Objection (31)Special Inspection (30)
08/31/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/14/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/28/2026
Permit issued — Mechanical Systems
M01090185-I1-MS
07/28/2026
Permit issued — Sprinklers
M01189286-I1-EW-SP
07/13/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Zhao Deng
07/13/2026
Special inspection requirement — HVAC-R and service water heating equipment
Zhao Deng
07/13/2026
Special inspection requirement — Mechanical Systems
Zhao Deng
07/13/2026
Special inspection requirement — Final
Zhao Deng
07/13/2026
Special inspection requirement — Shutoff dampers
Zhao Deng
07/13/2026
Special inspection requirement — Maintenance information
Zhao Deng
07/13/2026
Special inspection requirement — Ventilation and air distribution system
Zhao Deng
07/13/2026
Special inspection requirement — HVAC-R and service water heating system controls
Zhao Deng
07/10/2026
Filed — Alteration
INSTALL MECHANCIAL SYSTEM, INSTALL MECHANICAL EXHAUST HOOD WORK FOR COMMERCIAL KITCHEN OF EATING AND DRINKING ESTABLISH. NO CHANGE OF USE, OCCPANCY AND EGRESS.
M01090185-P1
07/09/2026
Special inspection requirement — Maintenance information
Zhao Deng
07/09/2026
Special inspection requirement — Mechanical Systems
Zhao Deng
07/09/2026
Special inspection requirement — HVAC-R and service water heating system controls
Zhao Deng
07/09/2026
Special inspection requirement — Ventilation and air distribution system
Zhao Deng
07/09/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Zhao Deng
07/09/2026
Special inspection requirement — Shutoff dampers
Zhao Deng
07/09/2026
Special inspection requirement — HVAC-R and service water heating equipment
Zhao Deng
07/09/2026
Special inspection requirement — Final
Zhao Deng
06/10/2026
Permit issued — General Construction
M01051794-I1-GC
06/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Zhao Deng
06/10/2026
Special inspection requirement — Sprinkler Systems
Zhao Deng
06/09/2026
Filed — Alteration
INSTALL NEW SPRINKLER SYSTEM AS PER PLAN. NO CHANGE OF USE, OCCUPANCY AND EGRESS.
M01189286-P1
06/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Zhao Deng
06/08/2026
Special inspection requirement — Sprinkler Systems
Zhao Deng
05/12/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/28/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/30/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/26/2025
Permit issued — Plumbing
M01052770-I1-PL
12/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Zhao Deng
12/11/2025
Special inspection requirement — Energy Code Compliance Inspections
Zhao Deng
12/10/2025
Filed — Alteration
INSTALL NEW PLUMBING FIXTURES AS PER PLANS FOR A SUPERMARKET RENOVATION. THERE IS NO CHANGE OF USE, EGRESS, OR OCCUPANCY FILED UNDER THIS PLAN.
M01052770-P1
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/30/2025
Objection raised — Fire_Protection
09/30/2025
Objection raised — Fire_Protection
09/30/2025
Objection raised — Scope
09/03/2025
Filed — Alteration CO
Proposed interior renovation of existing 3-story and cellar commercial building. Convert existing cellar storage to storage & food preparation area with commercial kitchen, utility & meter rooms. Obtain new Certificate of Occupancy.
M01051794-P2
09/03/2025
Special inspection requirement — Interior lighting power
Timothy Li
09/03/2025
Special inspection requirement — Energy Code Compliance Inspections
Timothy Li
09/03/2025
Special inspection requirement — Lighting controls
Timothy Li
09/03/2025
Special inspection requirement — Fire-Resistance Rated Construction
Timothy Li
08/21/2025
Special inspection requirement — Interior lighting power
Timothy Li
08/21/2025
Special inspection requirement — Fire-Resistance Rated Construction
Timothy Li
08/21/2025
Special inspection requirement — Energy Code Compliance Inspections
Timothy Li
08/21/2025
Special inspection requirement — Lighting controls
Timothy Li
08/04/2025
Objection resolved — Addressed
08/04/2025
Objection resolved — Addressed
08/04/2025
Objection resolved — Addressed
08/04/2025
Objection resolved — Addressed
08/04/2025
Objection resolved — Addressed
08/04/2025
Objection resolved — Addressed
07/24/2025
Objection raised — Energy
07/24/2025
Objection raised — Scope
07/24/2025
Objection raised — Scope
07/24/2025
Objection raised — Scope
07/24/2025
Objection raised — Cost
07/24/2025
Objection raised — Scope
Latest 60 of 122 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedBEYOND COOLING LLC07/28/2026
DOB NOWSprinklersPermit IssuedRRP PLUMBING CORP07/28/2026
DOB NOWGeneral ConstructionPermit IssuedMCNY CONTRACTING LLC06/10/2026
DOB NOWPlumbingPermit IssuedRRP PLUMBING CORP12/26/2025
DOB NOWGeneral ConstructionPermit IssuedMCNY CONTRACTING LLC07/01/2025
DOB NOWGeneral ConstructionPermit IssuedMCNY CONTRACTING LLC06/18/2025
DOB NOWFoundationPermit IssuedMCNY CONTRACTING LLC04/07/2025
DOB NOWMechanical SystemsPermit IssuedBEYOND COOLING LLC08/08/2024
DOB NOWGeneral ConstructionPermit IssuedMCNY CONTRACTING LLC07/17/2024
DOB NOWPlumbingPermit IssuedRRP PLUMBING CORP06/10/2024
DOB NOWPlumbingSigned-offMPS PLUMBING & HEATING IN11/08/2023
DOB NOWGeneral ConstructionSigned-offMCNY CONTRACTING LLC10/03/2023
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC09/13/2023
BISOTISSUEDMORGAN CONSTRUCTION NY INC02/19/2009
BISOTISSUEDMORGAN CONSTRUCTION NY INC02/06/2009
BISPLISSUEDMPS PLUMBING & HEATING INC08/10/2007
BISOTISSUEDJIAN NEW CONSTRUCTION07/26/2007
BISOTISSUEDJIAN NEW CONSTRUCTION INC.03/22/2007
BISEQISSUEDJIAN NEW CONSTRUCTION INC.03/22/2007
BISPLISSUEDTHEODORE WAGNER PLBG & HTG CORP08/12/1999
BISOTISSUEDHONG KONG CHOY CONSTRUCTION03/10/1999
BISMHISSUEDHKC CONSTRUCTION09/22/1998
BIS—ISSUEDD.I. GUIDE INC.04/25/1997
BIS—ISSUEDSHU NENG CONST.03/14/1997
BISPLISSUEDMAILLAND PLUMBING & HEATING,INC.03/03/1997
BISMHISSUEDMAILLAND PLUMBING & HEATING,INC.03/03/1997
BISOTISSUEDKINON CONSTRUXTION INC02/11/1997
1 project · most recent 07/10/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/10/2026Permit IssuedBEYOND COOLING LLCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PUHY-EP096TNU-A1 96,000 BTU · Vrf Outdoor ×1
PUHY-EP120TNU-A1 120,000 BTU · Vrf Outdoor ×1
PUHY-EP168TNU-A1 168,000 BTU · Vrf Outdoor ×1
PUZ-A24NHA7 24,000 BTU · Heat Pump Outdoor ×1
Ventilation
Greenheck USF-27-B4 7,850 CFM · Exhaust Fan ×1
1 project · most recent 06/09/2026
FiledStatusContractorScope
06/09/2026Permit IssuedRRP PLUMBING CORP80 heads
3 projects · most recent 08/06/2024
General Wiring
FiledStatusContractorScope
08/06/2024Permit IssuedUNITED ELEC'L CONT'G CORP—
01/09/2024Permit IssuedP.L. ELEC'L CONTR'G CORPGeneral Wiring
09/15/2023CompleteTOP SHELF ELECTRIC CORP—
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
08/31/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/14/2026Pass-Final CND-Occupancy InspectionPassView ↗
05/12/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/28/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/30/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/01/2024Pass-Final PL - UndergroundPassView ↗
11/16/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 53
DateRequirementInspectorRole
07/13/2026HVAC-R and service water piping design and insulationZhao Dengenergy_progress
07/13/2026HVAC-R and service water heating equipmentZhao Dengenergy_progress
07/13/2026Mechanical SystemsZhao Dengspecial
07/13/2026FinalZhao Dengprogress
07/13/2026Shutoff dampersZhao Dengenergy_progress
07/13/2026Maintenance informationZhao Dengenergy_progress
07/13/2026Ventilation and air distribution systemZhao Dengenergy_progress
07/13/2026HVAC-R and service water heating system controlsZhao Dengenergy_progress
07/09/2026Maintenance informationZhao Dengenergy_progress
07/09/2026Mechanical SystemsZhao Dengspecial
07/09/2026HVAC-R and service water heating system controlsZhao Dengenergy_progress
07/09/2026Ventilation and air distribution systemZhao Dengenergy_progress
07/09/2026HVAC-R and service water piping design and insulationZhao Dengenergy_progress
07/09/2026Shutoff dampersZhao Dengenergy_progress
07/09/2026HVAC-R and service water heating equipmentZhao Dengenergy_progress
07/09/2026FinalZhao Dengprogress
06/10/2026Fire-Resistant Penetrations and JointsZhao Dengspecial
06/10/2026Sprinkler SystemsZhao Dengspecial
06/08/2026Fire-Resistant Penetrations and JointsZhao Dengspecial
06/08/2026Sprinkler SystemsZhao Dengspecial
12/11/2025Fire-Resistant Penetrations and JointsZhao Dengspecial
12/11/2025Energy Code Compliance InspectionsZhao Dengprogress
09/03/2025Interior lighting powerTimothy Lienergy_progress
09/03/2025Energy Code Compliance InspectionsTimothy Liprogress
09/03/2025Lighting controlsTimothy Lienergy_progress
Latest 25 of 53.
▾Documents — 110 on file (BIS + DOB NOW)
▸Plans & Drawings19
▸DOB NOWPlans/Sketch19
08/29/2026M00931926-I1Request digital key ↗
08/28/2026M00921901-I1Request digital key ↗
08/28/2026M00921897-I1Request digital key ↗
Showing 3 of 19 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
02/23/2009110436573Open ↗
02/06/2009110436573Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
01/20/2009110436573Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWHouse Number Verification: TOPO Stamp3
08/13/2026M01051794-P2Open ↗
08/13/2026M01051794-I1Open ↗
08/13/2026M01051794-P1Open ↗
▸Seals & Professional Certifications53
▸DOB NOWProgress Inspector Seal & Signature23
09/07/2026M01069453-S2Open ↗
09/01/2026M00921897-I1Open ↗
09/01/2026M00921901-I1Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature19
08/29/2026M00931926-I1Open ↗
08/28/2026M00921897-I1Open ↗
08/28/2026M00921897-P1Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/07/2026M01069453-S2Open ↗
08/30/2026M01052770-I1Open ↗
08/27/2026M01189286-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
03/25/2009110436573Open ↗
02/05/2009110436573Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/13/2026M01051794-P2Open ↗
08/13/2026M01051794-I1Open ↗
08/13/2026M01051794-P1Open ↗
▸Environmental & Asbestos20
▸DOB NOWDEP ACP-5: Asbestos Assessment Report19
08/28/2026M00921897-I1Open ↗
08/28/2026M00921897-P1Open ↗
08/27/2026M00921488-I1Open ↗
Showing 3 of 19 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
01/20/2009110436573Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/24/2009110436573Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
01/20/2009110436573Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
03/24/2009110436573Open ↗
01/20/2009110436573Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
01/20/2009110436573Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification3
08/21/2026M01051794-P2Open ↗
08/15/2026M01051794-I1Open ↗
08/14/2026M01051794-P1Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
03/24/2009110436573Open ↗