← Back
General warehouse
551 EAST 179 STREET
BRONX · Tremont · BIN 2011848
💬 Discuss this project
1947Year Built
1Stories
E1Building Class
R7-1Zoning
7,500 sfGross Floor Area
2Units
2 Open Violations 1 unresolved · 1 paperwork only ▸FDNY Report ↗
General warehouse · Owner of record: 551 EAST 179 LLC · 7,609 sf lot · 0.99 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralEquipmentGeneral
Roof6p · 1 filing · 6 docs
Floor 15p · 1 filing · 6 docs
Filed — no permit issued1p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
STAR GREEN MANAGEMENT303/22/2026
BILLY ENTERPRISES203/21/2026
SCHAEFER GARDENS203/21/2026
179A STREET LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/18/2016$950K—179 STREET LLC → 179A STREET LLC$127/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BGM ENGINEERING102/24/2021
GREEN DESIGN107/29/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BENJAMIN DREBINElectrical503/21/2026
ACCURATE ELECL CORP 002950General Contractor403/22/2026
HATZLACHA HOME IMPROV *General Contractor303/21/2026
STEAMFITTERSElectrical203/21/2026
CRUZ, GEORGEElectrical203/21/2026
TIMOTHY COLEMANElectrical103/21/2026
TIMOTHY COLEMAN LICENSEDElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BGM ENGINEERING, LLC1514102/24/2021
Building Lifecycle
All (70)Filed (2)Permit Issued (1)Signed Off (1)Violation (51)Objection (8)Special Inspection (7)
05/24/2022
Violation issued (ECB, closed)
Construction
05/24/2022
Violation issued (ECB, open)
Construction
05/05/2022
Signed off — Alteration
HEREWITH TO REPLACE EXISTING STRUCTURAL JOISTS WITH NEW STEEL JOISTS
X00472685-I1
05/01/2021
Violation issued (ECB, closed)
Construction
04/07/2021
Permit issued — Structural
X00472685-I1-ST
03/16/2021
Violation issued (ECB, closed)
Construction
03/09/2021
Special inspection requirement — Post-installed Anchors
JOSEPH BADINTER
03/04/2021
Objection raised — Admin
03/04/2021
Objection resolved — Addressed
03/04/2021
Objection raised — Admin
03/04/2021
Objection resolved — Addressed
03/04/2021
Objection raised — Inspections
03/04/2021
Objection resolved — Addressed
03/04/2021
Objection raised — Admin
03/04/2021
Objection resolved — Addressed
03/03/2021
Special inspection requirement — Structural Cold-Formed Steel
JOSEPH BADINTER
02/24/2021
Filed — Alteration
HEREWITH TO REPLACE EXISTING STRUCTURAL JOISTS WITH NEW STEEL JOISTS
X00472685-I1
02/18/2021
Special inspection requirement — Structural Steel - High Strength Bolting
JOSEPH BADINTER
02/18/2021
Special inspection requirement — Structural Steel - Details
JOSEPH BADINTER
02/18/2021
Special inspection requirement — Final
JOSEPH BADINTER
02/18/2021
Special inspection requirement — Structural Steel - Welding
JOSEPH BADINTER
02/18/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
JOSEPH BADINTER
01/04/2021
Violation issued (ECB, closed)
Construction
10/07/2020
Violation issued (ECB, closed)
Construction
10/07/2020
Violation issued (ECB, closed)
Construction
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/18/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/12/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/12/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/29/2020
Filed — Alteration
ALTERATION TYPE 3 - CONSTRUCTION EQUIPMENT - SIDEWALK-SHED PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. LIVE LOAD300 PER SQUARE FEET.
X00373439-I1
06/03/2020
Violation issued (ECB, closed)
Construction
03/27/2020
Violation issued (ECB, closed)
Construction
03/27/2020
Violation issued (ECB, closed)
Construction
03/27/2020
Violation issued (ECB, closed)
Construction
03/27/2020
Violation issued (ECB, closed)
Construction
01/29/2020
Violation issued (ECB, closed)
Construction
01/29/2020
Violation issued (ECB, closed)
Construction
01/29/2020
Violation issued (ECB, closed)
Construction
01/29/2020
Violation issued (ECB, closed)
Construction
01/09/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/09/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/08/2020
Violation issued (ECB, closed)
Construction
12/12/2019
Violation issued (ECB, closed)
Construction
12/12/2019
Violation issued (ECB, closed)
Construction
12/12/2019
Violation issued (ECB, closed)
Construction
12/12/2019
Violation issued (ECB, closed)
Construction
11/27/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/27/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/27/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/13/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/29/2019
Violation issued (ECB, closed)
Construction
10/16/2019
Violation issued (ECB, closed)
Construction
10/16/2019
Violation issued (ECB, closed)
Construction
10/16/2019
Violation issued (ECB, closed)
Construction
10/16/2019
Violation issued (ECB, closed)
Construction
09/10/2019
Violation issued (ECB, closed)
Construction
08/26/2019
Violation issued (ECB, open)
Construction
08/26/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/26/2019
Violation issued (ECB, closed)
Construction
Latest 60 of 70 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offHATZLACHA HOME IMPROV *04/07/2021
BISOTISSUEDAA INSPECTION & BUILDING07/31/2020
2 projects · most recent 06/13/2023
General Wiring
FiledStatusContractorScope
06/13/2023CompleteACCURATE ELEC'L CORP.General Wiring
05/09/2022Permit IssuedTIMOTHY COLEMAN LICENSEDGeneral Wiring
1 project · most recent 07/29/2020
Sidewalk Shed
FiledStatusContractorScope
07/29/2020——Sidewalk Shed
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
03/09/2021Post-installed AnchorsJOSEPH BADINTERspecial
03/03/2021Structural Cold-Formed SteelJOSEPH BADINTERspecial
02/18/2021Structural Steel - High Strength BoltingJOSEPH BADINTERspecial
02/18/2021Structural Steel - DetailsJOSEPH BADINTERspecial
02/18/2021FinalJOSEPH BADINTERprogress
02/18/2021Structural Steel - WeldingJOSEPH BADINTERspecial
02/18/2021Structural Stability – Alterations of existing buildingsJOSEPH BADINTERspecial
▾Documents — 45 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Structural1
08/15/2026X00472685-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sidewalk Shed1
08/26/2026X00373439-I1Request digital key ↗
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION7
12/04/2020240290975Open ↗
11/10/2020240290975Open ↗
09/03/2020240275028Open ↗
Showing 3 of 7 on file for this type
▸BISWORK PERMIT APPLICATION1
08/04/2020240275028Open ↗
▸Seals & Professional Certifications12
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
08/04/2020240275028Open ↗
12/05/2019220721388Open ↗
04/08/2010220055277Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026X00373439-I1Open ↗
08/25/2026X00472685-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026X00472685-I1Open ↗
08/28/2026X00472685-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
07/15/2020240275028Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
04/08/2010220055277Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/15/2020240275028Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
04/08/2010220055277Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/28/2026X00472685-I1Open ↗
▸Safety & Tenant Protection4
▸BISTenant Protection Plan and Notes2
08/04/2020240275028Open ↗
12/05/2019220721388Open ↗
▸BISSTREET TREE CHECKLIST1
04/19/2010220055277Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
08/04/2020240275028Open ↗
▸Environmental & Asbestos3
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/27/2020240290975Open ↗
▸BISTHIS IS NOT AN ASBESTOS PROJECT1
04/14/2010220055277Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/15/2026X00472685-I1Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/15/2020240275028Open ↗
▸Approvals, Objections & Sign-offs7
▸BISLETTERS - SUPPORTING DOCUMENTATION4
08/04/2020240275028Open ↗
08/04/2020240275028Open ↗
08/04/2020240275028Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
04/08/2010220055277Open ↗
03/11/2010220051529Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
04/08/2010220055277Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
07/15/2020240275028Open ↗
12/05/2019220721388Open ↗
04/08/2010220055277Open ↗
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET3
12/05/2019220721388Open ↗
04/08/2010220055277Open ↗
03/11/2010220051529Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
07/15/2020240275028Open ↗
▸BISADDITIONAL INFORMATION1
09/08/2020240275028Open ↗