ECB12/08/2025UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. ORDER IN DOB VIOLATION VIO23-01327, DATED 5/5/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITION$25K due
ECB12/08/2025FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. NO CERTIFICATE OF CORRECTION ON FILE FOR VIO#39085672L AS OF 12/8/25.., FILE A CERTIFICATE O$6K due
ECB01/29/2025FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39086296L ISSUED ON 05/15/2023, AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2). AN ACCEPTABLE CERT$1K due
ECB01/31/2024FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-01327, DATED 5/5/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/11/202$2K due
ECB05/05/2023SECTIONS OF MISSING RUSTED OUT CEILING AT 2FL ROOF DRAIN HAS FALLEN OUT NEXT TO ELEVATOR. 1FL OBSERVED MISSING SECTION OF CONCRETE AT VARIOUS LOCATIONS EXPOSING WIRE MASH AT LOWER LEVEL OBSERVED RUSTED MISSING$1K due
DOB05/05/2023SECTIONS OF MISSING RUSTED OUT CEILING AT 2FL. 1FL OBSERVED MISSING SECTION OF CONCRETE AT VARIOUS LOCATIONS EXPOSING WIRE MASH AT LOWER LEVEL OBSERVED RUSTED MISSING SECTION OF Q DECKING EXPOSING WIRE MASH STREEL COLUMN LOCATED NEXT EXPOSURE 2,3 CONCRETE CASING HAS VARIOUS CRACKS AND PIECES MISSING STEEL IS RUSTED AND FLACKING OFF
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
DOB02/19/2002V-DOB VIOLATION - ACTIVE
DOB05/08/1996V-DOB VIOLATION - ACTIVE
ECB01/17/2006FAILURE TO MAINTAIN BLDG. NOTE: (1) SPALLING & CRACKED CONCRETE ON 1ST FLR (CEILING BEAMS) (2)DETERIORATED & WEAKENED, & ROTTED METAL Q-DECK, BELOW 1ST FLR SLAB (VARIOUS AREAS) REMEDY: MAINTAIN BLDG.Nothing owed — awaiting certificate of correction
ECB01/17/2006FAILURE TO POST THE C OF O. NOTE: NO C OF O POSTED IN PUBLIC GARAGE. REMEDY: POST C OF O.Nothing owed — awaiting certificate of correction
ECB05/24/2004FAILURE TO MAINTAIN BLDG ELEVATOR SHAFT DEFECTS NOTED:CRACK IN ELEVATOR SHAFT ABOVE 2ND FL AT EAST WALL AND ALSO AT LOCATION IN SHAFT.REMEDY:MAINTAIN BLDG MAKE SITE SAFE.Nothing owed — awaiting certificate of correction
ECB01/29/2004FAILURE TO MAINTAIN DEFECT ARE VERTICAL AND DIAGONAL CRACKS THROUGHOUT ELEVATOR SHAFT AND BEING WALLS REMEDY DISCONTINUE USE OF ELEVATOR UNTIL OR ENGINEER REPORT IS SUBMITTED TO THIS DEOT STRUCTURAL STABILITYNothing owed — awaiting certificate of correction