← Back
Miscellaneous two family
555 BAINBRIDGE STREET
BROOKLYN · Ocean Hill · BIN 3040661
💬 Discuss this project
1910Year Built
2Stories
B9Building Class
R6Zoning
2,700 sfGross Floor Area
2Units
Rent Stabilized3 Open Violations ▸FDNY Report ↗
Miscellaneous two family · 2,000 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 13 docs
Cellar1p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BRICKSTONE GROUP707/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/17/2022$2.5M—55 BRICKS LLC → Private party$926/sf building
11/24/2021$984K—BONIM BINYAN, INC. → 55 BRICKS LLC$364/sf building
02/18/2014$590K—Private party → BONIM BINYAN, INC$219/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DOYUN KIM; RA405/24/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC BUILDING SOLUTIONS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYC BUILDING SOLUTIONS COGeneral Contractor303/21/2026
HORBRIDGE PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DOYUN KIM; RA7415405/24/2022
Building Lifecycle
All (61)Filed (4)Permit Issued (2)Signed Off (2)Violation (36)Inspection (5)Special Inspection (12)
11/24/2025
Violation issued (HPD, open)
I
12/04/2024
Violation issued (HPD, open)
I
11/28/2023
Violation issued (HPD, open)
I
06/01/2022
Signed off — Alteration
HEREWITH TO PROPOSE TO RELAMINATEEXISTING WALLS, NEW GYPBOARD, ANDREPLACE FINISHES AS PER PLANS. EXISTING 3STORY, TWO (2) FAMILY DWELLING. NOCHANGE IN USE, OCCUPANCY, OR EGRESS
B00634119-I1
05/27/2022
Special inspection requirement — Final
DOYUN KIM
05/27/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
DOYUN KIM
05/27/2022
Special inspection requirement — Mechanical Systems
DOYUN KIM
05/24/2022
Signed off — Alteration
B00640143-I1
05/24/2022
Filed — Alteration
HEREWITH TO PROPOSE TO RELAMINATEEXISTING WALLS, NEW GYPBOARD, ANDREPLACE FINISHES AS PER PLANS. EXISTING 3STORY, TWO (2) FAMILY DWELLING. NOCHANGE IN USE, OCCUPANCY, OR EGRESS
B00634119-P1
05/19/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/19/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
05/19/2022
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
05/19/2022
Special inspection requirement — Maintenance information
DOYUN KIM
05/18/2022
Filed — Alteration
B00640143-P1
05/10/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/10/2022
Special inspection requirement — Maintenance information
DOYUN KIM
05/10/2022
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
05/10/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
03/29/2022
Special inspection requirement — Mechanical Systems
DOYUN KIM
03/29/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
DOYUN KIM
03/29/2022
Special inspection requirement — Final
DOYUN KIM
01/19/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/19/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/19/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/07/2022
Permit issued — Plumbing
B00640143-I1-PL
12/30/2021
Filed — Alteration
B00640143-I1
12/29/2021
Permit issued — General Construction
B00634119-I1-GC-CX
12/23/2021
Filed — Alteration
HEREWITH TO PROPOSE TO RELAMINATEEXISTING WALLS, NEW GYPBOARD, ANDREPLACE FINISHES AS PER PLANS. EXISTING 3STORY, TWO (2) FAMILY DWELLING. NOCHANGE IN USE, OCCUPANCY, OR EGRESS
B00634119-I1
09/07/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/16/2016
Violation issued (ECB, closed)
Unknown
06/16/2016
Violation issued (ECB, closed)
Unknown
06/01/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/01/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/26/2016
Violation issued (HPD, closed)
B
05/26/2016
Violation issued (HPD, closed)
B
05/26/2016
Violation issued (HPD, closed)
C
05/10/2016
Violation issued (HPD, closed)
B
05/10/2016
Violation issued (HPD, closed)
A
05/10/2016
Violation issued (HPD, closed)
B
04/11/2016
Violation issued (HPD, closed)
B
04/11/2016
Violation issued (HPD, closed)
B
04/11/2016
Violation issued (HPD, closed)
B
04/08/2016
Violation issued (HPD, closed)
B
04/08/2016
Violation issued (HPD, closed)
B
04/08/2016
Violation issued (HPD, closed)
B
03/11/2016
Violation issued (HPD, closed)
B
03/11/2016
Violation issued (HPD, closed)
B
03/11/2016
Violation issued (HPD, closed)
B
03/11/2016
Violation issued (HPD, closed)
B
03/11/2016
Violation issued (HPD, closed)
B
03/11/2016
Violation issued (HPD, closed)
B
03/11/2016
Violation issued (HPD, closed)
B
03/11/2016
Violation issued (HPD, closed)
B
03/11/2016
Violation issued (HPD, closed)
B
03/11/2016
Violation issued (HPD, closed)
B
03/01/2016
Violation issued (ECB, closed)
Plumbing
03/01/2016
Violation issued (ECB, closed)
Construction
02/29/2016
Violation issued (HPD, closed)
B
02/29/2016
Violation issued (HPD, closed)
C
05/29/2009
Violation issued (ECB, closed)
Construction
Latest 60 of 61 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offHORBRIDGE PLUMBING & HEAT01/07/2022
DOB NOWGeneral ConstructionSigned-offNYC BUILDING SOLUTIONS CO12/29/2021
2 projects · most recent 09/07/2023
HVAC Wiring General Wiring
FiledStatusContractorScope
09/07/2023Permit IssuedSNB ELECTRICAL CONTNG CORHVAC Wiring
11/23/2021CompleteC & A ELECTRICAL CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
05/19/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/10/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/19/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/19/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/19/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
05/27/2022FinalDOYUN KIMprogress
05/27/2022Structural Stability – Alterations of existing buildingsDOYUN KIMspecial
05/27/2022Mechanical SystemsDOYUN KIMspecial
05/19/2022Fire-Resistant Penetrations and JointsDOYUN KIMspecial
05/19/2022Energy Code Compliance InspectionsDOYUN KIMprogress
05/19/2022Maintenance informationDOYUN KIMenergy_progress
05/10/2022Maintenance informationDOYUN KIMenergy_progress
05/10/2022Energy Code Compliance InspectionsDOYUN KIMprogress
05/10/2022Fire-Resistant Penetrations and JointsDOYUN KIMspecial
03/29/2022Mechanical SystemsDOYUN KIMspecial
03/29/2022Structural Stability – Alterations of existing buildingsDOYUN KIMspecial
03/29/2022FinalDOYUN KIMprogress
▾Documents — 23 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/31/2026B00634119-P1Request digital key ↗
08/31/2026B00634119-I1Request digital key ↗
08/31/2026B00640143-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature6
09/25/2026B00640143-P1Open ↗
09/25/2026B00640143-P1Open ↗
08/29/2026B00634119-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/31/2026B00634119-P1Open ↗
08/31/2026B00634119-I1Open ↗
08/31/2026B00640143-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/25/2026B00640143-P1Open ↗
08/29/2026B00634119-P1Open ↗
08/24/2026B00634119-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/31/2026B00634119-I1Open ↗
08/31/2026B00634119-P1Open ↗
08/31/2026B00640143-P1Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00640143-I1Open ↗