| Owner | Filings | Most Recent |
|---|---|---|
| ZG 2nd Place | 19 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 12/04/2025 | $2.9M | — | — → — | $802/sf building |
| 01/31/2019 | $2.0M | — | — → — | $577/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| AJ Alduino Consulting Engineering | 1 | 12/05/2023 |
| Martin Partners ARCH+DESIGN | 1 | 12/04/2023 |
| Gilsanz Murray Steficek | 1 | 12/04/2023 |
| Tan Engineering | 2 | 12/15/2021 |
| Representative | Filings | Most Recent |
|---|---|---|
| Joseph Fellner | 2 | 03/21/2026 |
| KM Associates of New York | 3 | 03/21/2026 |
| K & M Associates | 3 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| American Quality Construction | General Contractor | 8 | 03/21/2026 |
| Omd Electrical | Electrical | 1 | 03/22/2026 |
| Power Surge Electric | Electrical | 1 | 03/22/2026 |
| The Metro Group Electric | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Crosscheck Inspection Services | 544 | 3 | 12/05/2023 |
| Tan Engineering | 1291 | 2 | 12/15/2021 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Signed-off | American Quality Construction | 04/08/2024 |
| DOB NOW | General Construction | Signed-off | American Quality Construction | 04/05/2024 |
| DOB NOW | General Construction | Signed-off | American Quality Construction | 03/29/2024 |
| DOB NOW | Mechanical Systems | Signed-off | American Quality Construction | 03/29/2024 |
| BIS | — | ISSUED | Innovative Ventures Team | 11/16/2021 |
| BIS | OT | ISSUED | Airitan Management | 07/15/2019 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 12/05/2023 | Signed-off | American Quality Construction | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Mitsubishi Electric MXZ-SM48NAMHZ 48,000 BTU · Heat Pump Outdoor ×1 Heating Mitsubishi Electric MXZ-SM48NAMHZ 48,000 BTU · Heat Pump Outdoor ×1 Ventilation Greenheck N/A 1 BTU · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/02/2021 | — | — | 5 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/02/2021 | — | — | Gas, Plumbing-Sprinkler, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/17/2025 | Complete | Omd Electrical | General Wiring |
| 07/16/2025 | Complete | The Metro Group Electric | General Wiring |
| 02/23/2024 | Complete | Cresco Electrical | General Wiring |
| 11/18/2023 | Complete | WCK Electric | General Wiring |
| 11/08/2021 | Complete | WCK Electric | General Wiring |
| 11/21/2019 | Complete | Power Surge Electric | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/05/2023 | Signed-off | American Quality Construction | Steel, Masonry, Wood |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 11/28/2023 | Fire-Resistant Penetrations and Joints | EUGENE BIFULCO | special |
| 11/28/2023 | Duct leakage testing, insulation and design | MARC NEWMAN | energy_progress |
| 11/28/2023 | Fenestration areas | MARC NEWMAN | energy_progress |
| 11/28/2023 | Air barrier - visual inspection | MARC NEWMAN | energy_progress |
| 11/28/2023 | Fenestration and door U-factor and product ratings | MARC NEWMAN | energy_progress |
| 11/28/2023 | Fenestration air leakage | MARC NEWMAN | energy_progress |
| 11/28/2023 | Lighting controls | MARC NEWMAN | energy_progress |
| 11/28/2023 | Maintenance information | MARC NEWMAN | energy_progress |
| 11/28/2023 | Electrical motors and elevators | MARC NEWMAN | energy_progress |
| 11/28/2023 | Permanent certificate | MARC NEWMAN | energy_progress |
| 11/28/2023 | Lighting in dwelling units | MARC NEWMAN | energy_progress |
| 11/28/2023 | HVAC-R and service water piping design and insulation | MARC NEWMAN | energy_progress |
| 11/28/2023 | HVAC-R and service water heating system controls | MARC NEWMAN | energy_progress |
| 11/28/2023 | Interior lighting power | MARC NEWMAN | energy_progress |
| 11/28/2023 | HVAC-R and service water heating equipment | MARC NEWMAN | energy_progress |
| 11/16/2023 | Tenant Protection Plan Compliance | EUGENE BIFULCO | special |
| 11/16/2023 | Tenant Protection Plan Compliance | EUGENE BIFULCO | special |
| 11/16/2023 | Tenant Protection Plan Compliance | EUGENE BIFULCO | special |
| 11/10/2023 | Masonry | EUGENE BIFULCO | special |
| 11/10/2023 | Final | MARC NEWMAN | progress |
| 11/10/2023 | Structural Stability – Alterations of existing buildings | EUGENE BIFULCO | special |
| 11/10/2023 | Mechanical Systems | EUGENE BIFULCO | special |
| 11/10/2023 | Structural Steel - Details | EUGENE BIFULCO | special |
| 11/10/2023 | Wood – Prefabricated I-Joists | EUGENE BIFULCO | special |
| 11/10/2023 | Final | MARC NEWMAN | progress |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| Ana Costa | Fitness / Recreation | Floors 1, 2 | Project B00960847 |