← Back
Two stories - detached, small or mid-size
56-24 230 STREET
QUEENS · Bayside · BIN 4161299
💬 Discuss this project
1950Year Built
2Stories
A1Building Class
R2Zoning
2,460 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 4,600 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 212p · 2 filings · 20 docs
Floor 111p · 2 filings · 20 docs
Cellar9p · 2 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALPHA HOME DESIGN LLC507/14/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
INDESIGN STUDIO1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FLUSHING ONE CONSTRUCTIONGeneral Contractor107/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
YAN GAO6619507/14/2022
Building Lifecycle
All (22)Filed (5)Permit Issued (2)Signed Off (2)Violation (1)Inspection (5)Special Inspection (7)
07/20/2022
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING 1-FAMILY BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00738615-I1
07/19/2022
Signed off — Alteration
PLUMBING WORK OF EXISTING 1-FAMILY BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00738641-I1
07/19/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/14/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 1-FAMILY BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00738615-P2
07/14/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/14/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/14/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
YAN GAO
07/14/2022
Special inspection requirement — Energy Code Compliance Inspections
YAN GAO
07/14/2022
Special inspection requirement — Fire-Resistance Rated Construction
YAN GAO
07/14/2022
Special inspection requirement — Interior lighting power
YAN GAO
07/13/2022
Filed — Alteration
PLUMBING WORK OF EXISTING 1-FAMILY BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00738641-P1
07/13/2022
Special inspection requirement — Energy Code Compliance Inspections
YAN GAO
07/13/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
YAN GAO
07/13/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
YAN GAO
06/30/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 1-FAMILY BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00738615-P1
06/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/19/2022
Permit issued — Plumbing
Q00738641-I1-PL
05/19/2022
Permit issued — General Construction
Q00738615-I1-GC
05/16/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 1-FAMILY BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00738615-I1
05/16/2022
Filed — Alteration
PLUMBING WORK OF EXISTING 1-FAMILY BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00738641-I1
08/26/2005
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC05/19/2022
DOB NOWGeneral ConstructionSigned-offFLUSHING ONE CONSTRUCTION05/19/2022
BISOTISSUEDLEE & COMPANY OF NY, INC06/26/2007
BISEQISSUEDSHIN AH WORLD CO09/06/2005
BIS—ISSUEDSHIN AH WORLD CO09/06/2005
BIS—ISSUEDSHIN AH WORLD CO08/16/2005
BISEQISSUEDSHIN AH WORLD CO08/16/2005
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/19/2022Pass-Final General Construction Non-Directive 14PassView ↗
07/14/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/14/2022Fail-Final General Construction Non-Directive 14FailView ↗
06/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/16/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
07/14/2022Fire-Resistant Penetrations and JointsYAN GAOspecial
07/14/2022Energy Code Compliance InspectionsYAN GAOprogress
07/14/2022Fire-Resistance Rated ConstructionYAN GAOprogress
07/14/2022Interior lighting powerYAN GAOenergy_progress
07/13/2022Energy Code Compliance InspectionsYAN GAOprogress
07/13/2022HVAC-R and service water piping design and insulationYAN GAOenergy_progress
07/13/2022Fire-Resistant Penetrations and JointsYAN GAOspecial
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/26/2026Q00738641-P1Request digital key ↗
08/26/2026Q00738641-I1Request digital key ↗
08/26/2026Q00738615-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026Q00738641-I1Open ↗
08/13/2026Q00738641-P1Open ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature5
09/15/2026Q00738641-P1Open ↗
09/15/2026Q00738641-P1Open ↗
09/04/2026Q00738615-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/26/2026Q00738641-I1Open ↗
08/26/2026Q00738641-P1Open ↗
08/26/2026Q00738615-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/15/2026Q00738641-P1Open ↗
09/04/2026Q00738615-P2Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/26/2026Q00738641-P1Open ↗
08/26/2026Q00738641-I1Open ↗
08/26/2026Q00738615-P1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026Q00738641-I1Open ↗
08/13/2026Q00738615-I1Open ↗