← Back
Primarily 3 family with 1 store or office
56 8 AVENUE
BROOKLYN · BIN 3024579
💬 Discuss this project
1901Year Built
4Stories
S3Building Class
R6AZoning
4,820 sfGross Floor Area
4Units
Primarily 3 family with 1 store or office · Owner of record: 85 7TH AVENUE LLC · 1,907 sf lot · 2.53 FAR built · Flood zone X
Locations of Work
Structural
Permit Issued — active, not yet Signed-off
Floor 1Under Construction1p · 1 filing · 14 docs
Sub-BasementUnder Construction2p · 1 filing · 14 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JUST CONSULTING ENGINEERING105/18/2026
BCHEN ARCHITECT PLLC105/14/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TEAM METRO CONSTRUCTION CGeneral Contractor207/11/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JUST CONSULTING ENGINEERI5865105/18/2026
Building Lifecycle
All (11)Filed (2)Permit Issued (2)Special Inspection (7)
07/10/2026
Permit issued — Mechanical Systems
B01297697-I1-GC-CX
07/10/2026
Permit issued — Structural
B01297697-S1-ST
05/18/2026
Filed — Alteration
installation of new sliding door at rear yard basement floor. Install new mini-split system for basement and 1st floor only. no change to use egress of occupancy
B01297697-S1
05/14/2026
Filed — Alteration
installation of new sliding door at rear yard basement floor. Install new mini-split system for basement and 1st floor only. no change to use egress of occupancy
B01297697-I1
05/11/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
XIAOJUN WANG
05/11/2026
Special inspection requirement — Structural Steel - Details
XIAOJUN WANG
05/11/2026
Special inspection requirement — Final
XIAOJUN WANG
10/03/2025
Special inspection requirement — Mechanical Systems
billy chen
10/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
billy chen
10/03/2025
Special inspection requirement — Final
billy chen
10/03/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
billy chen
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offTEAM METRO CONSTRUCTION C07/10/2026
DOB NOWStructuralPermit IssuedTEAM METRO CONSTRUCTION C07/10/2026
BISOTISSUEDBROOKLYN SOLARWORKS LLC10/03/2023
BISPLISSUEDM C M PLBG & HTG, INC11/09/2006
BISOTISSUEDMINCH CONSTRUCTION CORP11/02/2006
BISOTISSUEDJABUS BUILDING CORP10/29/1998
BISOTISSUEDDAVID OTHWAITE INC10/08/1996
1 project · most recent 05/18/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/18/2026Permit IssuedTEAM METRO CONSTRUCTION CHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric pumy-p60nkmu3 5 tons · Vrf Outdoor ×1
1 project · most recent 11/09/2023
FiledStatusContractorScope
11/09/2023CompleteBROOKYLN SOLARWORKS, LLC—
1 project · most recent 05/18/2026
Steel
FiledStatusContractorScope
05/18/2026Signed-offTEAM METRO CONSTRUCTION CSteel
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
05/11/2026Structural Stability – Alterations of existing buildingsXIAOJUN WANGspecial
05/11/2026Structural Steel - DetailsXIAOJUN WANGspecial
05/11/2026FinalXIAOJUN WANGprogress
10/03/2025Mechanical Systemsbilly chenspecial
10/03/2025Fire-Resistant Penetrations and Jointsbilly chenspecial
10/03/2025Finalbilly chenprogress
10/03/2025Fenestration and door U-factor and product ratingsbilly chenenergy_progress
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026B01297697-I1Request digital key ↗
08/17/2026B01297697-S1Request digital key ↗
▸Applications & Permits4
▸DOB NOWLPC Approval/Permit2
08/17/2026B01297697-I1Open ↗
08/17/2026B01297697-S1Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
10/02/2023340901741Open ↗
▸BISWORK PERMIT APPLICATION1
10/03/2023340901741Open ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026B01297697-S1Open ↗
09/01/2026B01297697-I1Open ↗
09/01/2026B01297697-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026B01297697-S1Open ↗
09/01/2026B01297697-I1Open ↗
09/01/2026B01297697-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026B01297697-S1Open ↗
08/17/2026B01297697-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/02/2023340901741Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/02/2023340901741Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/02/2023340901741Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/17/2026B01297697-S1Open ↗
08/17/2026B01297697-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/02/2023340901741Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
02/08/2024340901741Open ↗
10/17/2023340901741Open ↗
10/02/2023340901741Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
02/13/2024340901741Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
10/02/2023340901741Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
02/08/2024340901741Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/02/2023340901741Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
02/08/2024340901741Open ↗
10/17/2023340901741Open ↗
10/02/2023340901741Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLANDMARKS APPROVAL2
02/13/2024340901741Open ↗
10/02/2023340901741Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
02/13/2024340901741Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/13/2024340901741Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
02/08/2024340901741Open ↗
10/02/2023340901741Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
10/02/2023340901741Open ↗