General warehouse
56-85 49 STREET
QUEENS · BIN 4058928
💬 Discuss this project
1966Year Built
1Stories
E1Building Class
M3-1Zoning
17,320 sfGross Floor Area
1Units
0 Open Violations
General warehouse · Owner of record: TERRENO 14605 MILLER AVE LLC · 94,842 sf lot · 0.18 FAR built · Flood zone X500
Locations of Work
Plumbing
Basement2p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TERRENO REALTY1203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BL COMPANIES403/12/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RPO803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FORTE EXPRESS P & H INCPlumbing107/08/2026
Building Lifecycle
All (15)Filed (4)Permit Issued (1)Signed Off (1)Violation (4)Special Inspection (5)
08/07/2020
Signed off — Alteration
Plumbing work as per submitted plans. No change in Egress, Use or Occupancy.
Q00254147-I1
05/14/2020
Permit issued — Plumbing
Q00254147-I1-PL
03/12/2020
Filed — Alteration
Plumbing work as per submitted plans. No change in Egress, Use or Occupancy.
Q00254147-P1
03/12/2020
Filed — Alteration
Mechanical work as per submitted plans. No change in egress, use or occupancy.
Q00254084-P1
03/12/2020
Special inspection requirement — Mechanical Systems
03/12/2020
Special inspection requirement — Final
BLAIR RICHARDSON
02/21/2020
Special inspection requirement — Mechanical Systems
02/21/2020
Special inspection requirement — Final
02/21/2020
Special inspection requirement — Duct leakage testing
12/17/2019
Filed — Alteration
Plumbing work as per submitted plans. No change in Egress, Use or Occupancy.
Q00254147-I1
12/17/2019
Filed — Alteration
Mechanical work as per submitted plans. No change in egress, use or occupancy.
Q00254084-I1
01/04/2000
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
01/04/2000
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
01/04/2000
Violation issued (ECB, closed)
Construction
01/03/2000
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offFORTE EXPRESS P & H INC05/14/2020
BISOTISSUEDBLUE ROCK CONSTRUCTION IN05/19/2020
1 project · most recent 03/12/2020
Air Conditioning Systems Associated Ducts and Piping
FiledStatusContractorScopeMake / Model / Capacity
03/12/2020——Air Conditioning Systems, Associated Ducts and Piping
Cooling
Trane YCH036 2,400 CFM · Rooftop Unit ×10
4TTA097036A3 36,000 BTU · Condensing Unit ×5
Mitsubishi Electric TUMYP060 60,000 BTU · Vrf Outdoor ×5
Ducts & Piping
Trane TAM9A 3,600 tons · Fan Coil Indoor ×10
1 project · most recent 02/11/2021
General Wiring
FiledStatusContractorScope
02/11/2021Permit IssuedCONTROL ELEC'L CONT'G CORGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/12/2020Mechanical Systems—special
03/12/2020FinalBLAIR RICHARDSONprogress
02/21/2020Mechanical Systems—special
02/21/2020Final—progress
02/21/2020Duct leakage testing —energy_progress
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Plumbing2
08/28/2026Q00254147-I1Request digital key ↗
08/15/2026Q00254147-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems2
08/28/2026Q00254084-I1Request digital key ↗
08/15/2026Q00254084-P1Request digital key ↗
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
05/29/2020421939727Open ↗
05/22/2020421939727Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
11/27/2019421939727Open ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/28/2026Q00254084-P1Open ↗
08/28/2026Q00254084-I1Open ↗
08/28/2026Q00254147-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
11/27/2019421939727Open ↗
11/27/2019421939727Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/27/2019421939727Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
11/27/2019421939727Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/28/2026Q00254084-I1Open ↗
▸Environmental & Asbestos4
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)2
06/29/2020421939727Open ↗
05/29/2020421939727Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/28/2026Q00254084-I1Open ↗
08/13/2026Q00254147-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
06/04/2021421939727Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
06/04/2021421939727Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/27/2019421939727Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
06/04/2021421939727Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
05/29/2020421939727Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/04/2021421939727Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT (FINAL): PW31
06/04/2021421939727Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
11/27/2019421939727Open ↗
▸BISADDITIONAL INFORMATION1
10/16/2020421939727Open ↗