| Owner | Filings | Most Recent |
|---|---|---|
| REDLINE CONSTRUCTION MAINTENANCE | 31 | 07/08/2026 |
| Redline Construction | 2 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| JOSEPH M. MORACE, A.I.A., ARCHITECT | 7 | 03/29/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| PATRICIA L GASS | 12 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| REDLINE CONSTRUCTION & MA | General Contractor | 14 | 07/08/2026 |
| FINE MECHANICAL CORP | Plumbing | 2 | 07/08/2026 |
| HIGH BEAM ELECTRIC CORP. | Electrical | 1 | 03/22/2026 |
| QUALITY PLUMBING, INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| A TECH ENGINEERING NYC, P | 6738 | 1 | 07/15/2021 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Permit Issued | REDLINE CONSTRUCTION & MA | 07/14/2022 |
| DOB NOW | Curb Cut | Signed-off | REDLINE CONSTRUCTION & MA | 06/30/2022 |
| DOB NOW | Plumbing | Signed-off | FINE MECHANICAL CORP | 05/20/2022 |
| DOB NOW | Plumbing | Signed-off | QUALITY PLUMBING, INC | 02/10/2022 |
| DOB NOW | Plumbing | Signed-off | FINE MECHANICAL CORP | 01/05/2022 |
| DOB NOW | Mechanical Systems | Permit Issued | REDLINE CONSTRUCTION & MA | 11/30/2021 |
| DOB NOW | Construction Fence | Signed-off | REDLINE CONSTRUCTION & MA | 11/24/2021 |
| DOB NOW | Earth Work | Signed-off | REDLINE CONSTRUCTION & MA | 11/23/2021 |
| DOB NOW | Construction Fence | Signed-off | REDLINE CONSTRUCTION & MA | 08/11/2021 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 03/29/2022 | Permit Issued | REDLINE CONSTRUCTION & MA | Ventilation Systems | Ventilation Broan-Nutone 670 50 CFM · Exhaust Fan ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/02/2022 | Complete | HIGH BEAM ELECTRIC CORP. | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/29/2022 | Permit Issued | REDLINE CONSTRUCTION & MA | Concrete, Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 11/30/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 11/18/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 11/18/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 08/19/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 07/28/2022 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 07/06/2022 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 07/06/2022 | Pass-Final Fence Non-Directive 14 | Pass | View ↗ |
| 06/23/2022 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 06/21/2022 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 05/26/2022 | Certified Sprinkler (PL)-Sprinkler-Hydro | Certified | View ↗ |
| 05/26/2022 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 05/25/2022 | Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish | Certified | View ↗ |
| 05/25/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 04/25/2022 | Certified Storm Drainage-ST-Fixtures-Finish | Certified | View ↗ |
| 04/21/2022 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 02/04/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 02/04/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 01/19/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 11/02/2021 | Final | anthony santoro | progress |
| 06/29/2021 | Subsurface Investigations (Borings/Test Pits) | anthony santoro | special |
| 06/29/2021 | Concrete - Cast-In-Place | anthony santoro | special |
| 06/29/2021 | Fire-Resistant Penetrations and Joints | anthony santoro | special |
| 06/29/2021 | Subgrade Inspections | anthony santoro | special |
| 06/29/2021 | Interior lighting power | anthony santoro | energy_progress |
| 06/29/2021 | Ventilation and air distribution system | anthony santoro | energy_progress |
| 06/29/2021 | Electric vehicle service equipment requirements | anthony santoro | energy_progress |
| 06/29/2021 | HVAC-R and service water heating equipment | anthony santoro | energy_progress |
| 06/29/2021 | Energy Code Compliance Inspections | anthony santoro | progress |
| 06/29/2021 | Fire-Resistance Rated Construction | anthony santoro | progress |
| 06/29/2021 | Structural Wood Frame | anthony santoro | progress |
| 06/29/2021 | Maintenance information | anthony santoro | energy_progress |
| 06/29/2021 | Air barrier — testing | anthony santoro | energy_progress |
| 06/29/2021 | Fenestration air leakage | anthony santoro | energy_progress |
| 06/29/2021 | Permanent certificate | anthony santoro | energy_progress |
| 06/29/2021 | HVAC-R and service water heating system controls | anthony santoro | energy_progress |
| 06/29/2021 | Air barrier - visual inspection | anthony santoro | energy_progress |
| 06/29/2021 | Protection of exposed foundation insulation | anthony santoro | energy_progress |
| 06/29/2021 | Fenestration and door U-factor and product ratings | anthony santoro | energy_progress |
| 06/29/2021 | HVAC-R and service water piping design and insulation | anthony santoro | energy_progress |
| 06/29/2021 | Duct leakage testing, insulation and design | anthony santoro | energy_progress |
| 06/29/2021 | Insulation placement and R values | anthony santoro | energy_progress |
| 06/29/2021 | Fenestration areas | anthony santoro | energy_progress |
| 06/28/2021 | Final | anthony santoro | progress |