← Back
Primarily 4 family with 1 store or office
5623 FT HAMILTON PARKWAY
BROOKLYN · Borough Park · BIN 3139964
💬 Discuss this project
1931Year Built
3Stories
S4Building Class
R5Zoning
5,350 sfGross Floor Area
5Units
Rent Stabilized8 Open Violations ▸FDNY Report ↗
Primarily 4 family with 1 store or office · Owner of record: RICH REALTY CORP · 2,079 sf lot · 2.57 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 14p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RICH REALTY CORP303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MSM ENGINEERING SERVICES, PLLC507/30/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MODERN BUILDING CONSULTANT503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JZ CONSTRUCTION GROUP INCGeneral Contractor303/21/2026
PREMIER FLOW PLBG AND HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MSM ENGINEERING SERVICES,8449507/30/2024
Building Lifecycle
All (52)Filed (5)Permit Issued (2)Violation (27)Inspection (3)Objection (4)Special Inspection (11)
05/04/2026
Violation issued (HPD, closed)
A
06/09/2025
Violation issued (HPD, closed)
A
02/26/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/21/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/30/2024
Filed — Alteration
File to address ECB violations 39106254Z, 39106253R. Remove illegal mezzanine and partition at 1st floor as per plan. Restore back to legal conditions. No change in use, egress, or occupancy.
B01021030-P3
07/30/2024
Special inspection requirement — Energy Code Compliance Inspections
MOHAMED MAHMOUD
07/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOHAMED MAHMOUD
07/30/2024
Special inspection requirement — Tenant Protection Plan Compliance
07/30/2024
Special inspection requirement — Interior lighting power
MOHAMED MAHMOUD
07/30/2024
Special inspection requirement — Fire-Resistance Rated Construction
MOHAMED MAHMOUD
07/19/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOHAMED MAHMOUD
07/18/2024
Special inspection requirement — Tenant Protection Plan Compliance
07/18/2024
Special inspection requirement — Energy Code Compliance Inspections
MOHAMED MAHMOUD
07/12/2024
Objection resolved — Addressed
07/05/2024
Objection raised — Scope
06/27/2024
Filed — Alteration
File to address ECB violations 39106254Z, 39106253R. Remove illegal mezzanine and partition at 1st floor as per plan. Restore back to legal conditions. No change in use, egress, or occupancy.
B01021030-P2
06/18/2024
Objection raised — Zoning
06/18/2024
Objection resolved — Addressed
06/07/2024
Filed — Alteration
File to address ECB violations 39106254Z, 39106253R. Remove illegal mezzanine and partition at 1st floor as per plan. Restore back to legal conditions. No change in use, egress, or occupancy.
B01021030-P1
06/07/2024
Special inspection requirement — Energy Code Compliance Inspections
MOHAMED MAHMOUD
06/07/2024
Special inspection requirement — Tenant Protection Plan Compliance
06/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOHAMED MAHMOUD
05/03/2024
Permit issued — Plumbing
B01021030-S1-PL
04/25/2024
Permit issued — General Construction
B01021030-I1-GC
03/18/2024
Filed — Alteration
File to address ECB violations 39106254Z, 39106253R. Remove illegal mezzanine and partition at 1st floor as per plan. Restore back to legal conditions. No change in use, egress, or occupancy.
B01021030-S1
03/18/2024
Filed — Alteration
File to address ECB violations 39106254Z, 39106253R. Remove illegal mezzanine and partition at 1st floor as per plan. Restore back to legal conditions. No change in use, egress, or occupancy.
B01021030-I1
02/27/2024
Violation issued (HPD, closed)
C
02/16/2024
Violation issued (ECB, open)
Construction
02/16/2024
Violation issued (ECB, closed)
Construction
11/21/2023
Violation issued (HPD, closed)
I
03/22/2023
Violation issued (HPD, closed)
A
11/09/2022
Violation issued (HPD, closed)
I
02/24/2022
Violation issued (HPD, closed)
A
02/24/2022
Violation issued (HPD, closed)
I
04/08/2021
Violation issued (HPD, closed)
I
04/08/2021
Violation issued (HPD, closed)
A
10/30/2019
Violation issued (HPD, closed)
I
10/27/2018
Violation issued (ECB, closed)
Construction
10/17/2018
Violation issued (HPD, closed)
I
11/26/2017
Violation issued (HPD, open)
A
11/26/2017
Violation issued (HPD, open)
A
11/26/2017
Violation issued (HPD, open)
A
11/26/2017
Violation issued (HPD, open)
A
11/28/2016
Violation issued (HPD, open)
B
11/28/2016
Violation issued (HPD, open)
B
11/28/2016
Violation issued (HPD, open)
B
11/09/2016
Violation issued (HPD, closed)
I
10/09/2015
Violation issued (HPD, closed)
I
10/01/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/03/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/20/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offGALICJA PLBG AND HTG.CORP05/03/2024
DOB NOWGeneral ConstructionSigned-offJZ CONSTRUCTION GROUP INC04/25/2024
1 project · most recent 07/30/2024
Water/Sanitary
FiledStatusContractorScope
07/30/2024Signed-offPREMIER FLOW PLBG AND HTGWater/Sanitary
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
02/26/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/21/2024Pass-Final General Construction Non-Directive 14PassView ↗
07/19/2024Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
07/30/2024Energy Code Compliance InspectionsMOHAMED MAHMOUDprogress
07/30/2024Fire-Resistant Penetrations and JointsMOHAMED MAHMOUDspecial
07/30/2024Tenant Protection Plan Compliance—special
07/30/2024Interior lighting powerMOHAMED MAHMOUDenergy_progress
07/30/2024Fire-Resistance Rated ConstructionMOHAMED MAHMOUDprogress
07/18/2024Fire-Resistant Penetrations and JointsMOHAMED MAHMOUDspecial
07/18/2024Tenant Protection Plan Compliance—special
07/18/2024Energy Code Compliance InspectionsMOHAMED MAHMOUDprogress
06/07/2024Energy Code Compliance InspectionsMOHAMED MAHMOUDprogress
06/07/2024Tenant Protection Plan Compliance—special
06/07/2024Fire-Resistant Penetrations and JointsMOHAMED MAHMOUDspecial
▾Documents — 23 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/24/2026B01021030-I1Request digital key ↗
08/24/2026B01021030-P1Request digital key ↗
08/24/2026B01021030-P3Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications13
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/24/2026B01021030-S1Open ↗
08/24/2026B01021030-I1Open ↗
08/24/2026B01021030-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/19/2026B01021030-P2Open ↗
08/30/2026B01021030-P3Open ↗
08/30/2026B01021030-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/19/2026B01021030-P2Open ↗
08/30/2026B01021030-P3Open ↗
08/26/2026B01021030-S1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/24/2026B01021030-S1Open ↗
08/24/2026B01021030-I1Open ↗
08/24/2026B01021030-P3Open ↗
Showing 3 of 5 on file for this type