← Back
BuildNYC
Public elementary, junior or senior high
564 JACKSON AVENUE
BRONX · BIN 2004548
💬 Discuss this project
1960Year Built
4Stories
W1Building Class
R7-1Zoning
77,627 sfGross Floor Area
1Units
LL97 Covered4 Active Violations 0 unresolved · 4 paperwork only 2 likely answered ▸
Public elementary, junior or senior high · Owner of record: NYC Department of Parks and Recreation · 93,000 sf lot · 0.83 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentGeneralOther
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofNew York City School Construction Authority, P. S. 5Under Construction27p · 2 filings · 18 docs
Floor 1P. S. 5Under Construction36p · 2 filings · 18 docs
CellarP. S. 5Under Construction7p · 1 filing · 20 docs
Site & exteriorNew York City School Construction Authority, P. S. 5 +1Under Construction26p · 7 filings · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC School Construction Authority6607/10/2026
NYC Department of Education803/22/2026
National Grid103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Solid Engineering307/02/2026
Salam & Giacalone Architects608/05/2025
HRM Engineering Services408/05/2025
Dseny Engineering Services105/14/2025
Ame Services409/20/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Ame Services803/21/2026
Precision 3Sixty NYC2003/21/2026
Dseny Engineering Services203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CVM ConstructionScaffold1804/09/2026
WDFGeneral Contractor407/10/2026
King Hoist & ScaffoldingScaffold203/21/2026
Samco ElectricElectrical103/22/2026
EnvirotracScaffold104/09/2026
WDFScaffold107/08/2026
Prince ElectricElectrical103/21/2026
WDFPlumbing107/08/2026
A & S ElectricElectrical103/21/2026
Stanco System Electrical ContElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MP Engineers & Architects1438208/05/2025
Tectonic Engineering Cons106808/05/2025
Twin Peaks317109/02/2022
Building Lifecycle
All (143)Filed (18)Permit Issued (20)Signed Off (5)Violation (60)Objection (10)Special Inspection (30)
07/09/2026
Permit issued — General Construction
X01165593-I1-GC
07/02/2026
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW JOB #X01085184 and X01165593.
X01274868-P1
06/25/2026
Violation issued (ECB, open)
Construction
06/25/2026
Violation issued (ECB, open)
Construction
01/28/2026
Permit issued — Sidewalk Shed
X01285891-I1-SH
01/28/2026
Permit issued — Construction Fence
X01274868-I1-FN
01/28/2026
Permit issued — General Construction
X01085184-I1-GC
01/28/2026
Permit issued — Mechanical Systems
X01085184-S1-MS
01/28/2026
Permit issued — Structural
X01085184-S3-ST
01/28/2026
Permit issued — Plumbing
X01085184-S2-PL
01/20/2026
Signed off — Alteration
X01219911-I1
01/03/2026
Objection resolved — Addressed
12/03/2025
Signed off — Alteration
X07993296-I1
11/20/2025
Filed — Alteration
X01285891-I1
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/28/2025
Signed off — Alteration
X07993293-I1
10/28/2025
Signed off — Alteration
X08005511-I1
10/28/2025
Signed off — Alteration
X07993295-I1
09/11/2025
Objection raised — Other
09/04/2025
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW JOB #X01085184 and X01165593.
X01274868-I1
08/07/2025
Violation issued (ECB, open)
Construction
08/07/2025
Violation issued (ECB, closed)
Construction
08/07/2025
Violation issued (ECB, closed)
Construction
08/07/2025
Violation issued (ECB, open)
Construction
08/06/2025
Special inspection requirement — Final
GEORGE GHEBRYAL
08/06/2025
Special inspection requirement — Mechanical Systems
JAMES WILSON
08/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
08/06/2025
Special inspection requirement — Final
GEORGE GHEBRYAL
08/06/2025
Special inspection requirement — Energy Code Compliance Inspections
JAMES WILSON
08/06/2025
Special inspection requirement — Maintenance information
JAMES WILSON
08/06/2025
Special inspection requirement — Interior lighting power
JAMES WILSON
08/06/2025
Special inspection requirement — Shutoff dampers
JAMES WILSON
08/06/2025
Special inspection requirement — HVAC-R and service water heating system controls
JAMES WILSON
08/06/2025
Special inspection requirement — Duct leakage testing, insulation and design
JAMES WILSON
08/06/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
JAMES WILSON
08/06/2025
Special inspection requirement — Electrical motors and elevators
JAMES WILSON
08/06/2025
Special inspection requirement — HVAC-R and service water heating equipment
JAMES WILSON
08/06/2025
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
GEORGE GHEBRYAL
08/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
08/06/2025
Special inspection requirement — Fire-Resistance Rated Construction
GEORGE GHEBRYAL
08/06/2025
Special inspection requirement — Energy Code Compliance Inspections
JAMES WILSON
08/06/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
JAMES WILSON
08/06/2025
Special inspection requirement — Fenestration air leakage
JAMES WILSON
08/06/2025
Special inspection requirement — Fenestration areas
JAMES WILSON
08/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
08/06/2025
Special inspection requirement — Structural Steel - High Strength Bolting
GEORGE GHEBRYAL
08/06/2025
Special inspection requirement — Structural Steel - Details
GEORGE GHEBRYAL
08/06/2025
Special inspection requirement — Structural Steel - Welding
GEORGE GHEBRYAL
08/06/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
GEORGE GHEBRYAL
08/05/2025
Filed — Alteration
Cap and remove water piping for removed fixtures and remove bathroom fixtures in locker rooms. Install new storm piping and connect to existing.
X01085184-P4
08/05/2025
Filed — Alteration
Cap and remove water piping for removed fixtures and remove bathroom fixtures in locker rooms. Install new storm piping and connect to existing.
X01085184-P1
08/05/2025
Filed — Alteration
Cap and remove water piping for removed fixtures and remove bathroom fixtures in locker rooms. Install new storm piping and connect to existing.
X01085184-P2
08/05/2025
Filed — Alteration
Cap and remove water piping for removed fixtures and remove bathroom fixtures in locker rooms. Install new storm piping and connect to existing.
X01085184-P3
08/01/2025
Special inspection requirement — Fenestration areas
JAMES WILSON
08/01/2025
Special inspection requirement — Structural Steel - Details
GEORGE GHEBRYAL
08/01/2025
Special inspection requirement — Structural Steel - High Strength Bolting
GEORGE GHEBRYAL
08/01/2025
Special inspection requirement — Structural Steel - Welding
GEORGE GHEBRYAL
08/01/2025
Special inspection requirement — Final
GEORGE GHEBRYAL
06/25/2025
Permit issued — Construction Fence
X01219911-I1-FN
Latest 60 of 143 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedWDF07/09/2026
DOB NOWSidewalk ShedPermit IssuedKing Hoist & Scaffolding01/28/2026
DOB NOWConstruction FencePermit IssuedWDF01/28/2026
DOB NOWGeneral ConstructionPermit IssuedWDF01/28/2026
DOB NOWMechanical SystemsPermit IssuedWDF01/28/2026
DOB NOWStructuralPermit IssuedWDF01/28/2026
DOB NOWPlumbingPermit IssuedWDF01/28/2026
DOB NOWConstruction FenceSigned-offEnvirotrac06/25/2025
DOB NOWSidewalk ShedSigned-offCVM Construction11/13/2023
DOB NOWSupported ScaffoldSigned-offCVM Construction11/13/2023
DOB NOWConstruction FenceSigned-offCVM Construction11/13/2023
DOB NOWProtection and Mechanical MethodsSigned-offCVM Construction11/13/2023
DOB NOWConstruction FenceSigned-offCVM Construction11/14/2022
DOB NOWSupported ScaffoldSigned-offCVM Construction11/14/2022
DOB NOWSidewalk ShedSigned-offCVM Construction11/14/2022
DOB NOWProtection and Mechanical MethodsSigned-offCVM Construction11/14/2022
DOB NOWProtection and Mechanical MethodsSigned-offCVM Construction10/21/2022
DOB NOWSupported ScaffoldSigned-offCVM Construction10/13/2022
DOB NOWSidewalk ShedSigned-offCVM Construction10/13/2022
DOB NOWConstruction FenceSigned-offCVM Construction10/06/2022
BISPLISSUEDVarsity Plumbing and Heating10/20/2025
BISOTISSUEDCVM Construction12/30/2024
BISOTISSUEDCVM Construction11/15/2024
BISPLISSUEDVarsity Plumbing and Heating10/23/2024
BISOTISSUEDCVM Construction11/13/2023
BISPLISSUEDVarsity Plumbing and Heating10/27/2023
BISOTISSUEDCVM Construction11/14/2022
BISPLISSUEDVarsity Plumbing and Heating11/03/2022
BISOTISSUEDCVM Construction11/03/2022
BISEQISSUEDWhitestone Construction09/20/2022
BISEQISSUEDWhitestone Construction09/20/2022
BISEQISSUEDWhitestone Construction09/16/2021
BISEQISSUEDWhitestone Construction09/16/2021
BISEQISSUEDWhitestone Construction09/29/2020
BISEQISSUEDWhitestone Construction09/29/2020
BISEQISSUEDWhitestone Construction10/21/2019
BISEQISSUEDWhitestone Construction10/21/2019
BISOTISSUEDStanco Systems Electrical01/26/2016
BISOTISSUEDStanco Systems Electrical03/17/2015
BISOTISSUEDStanco Systems Electrical08/11/2014
+ 23 more permits on file
1 project · most recent 08/05/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/05/2025Permit IssuedWDFHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin RXYQ72AATJA 72,000 BTU · Vrf Outdoor ×2
Ventilation
Daikin FXAQ24PVJU 18,000 BTU · Vrf Indoor ×6
Oxygen8 B220U 900 CFM · Erv ×2
1 project · most recent 08/05/2025
Water/Sanitary
FiledStatusContractorScope
08/05/2025Permit IssuedWDFWater/Sanitary
20 projects · most recent 04/23/2026
General Wiring Lighting
FiledStatusContractorScope
04/23/2026Pending PaymentEverest ElectricGeneral Wiring
01/23/2026Permit IssuedStanco System Electrical Cont—
09/18/2025Permit IssuedRNH Electric CompanyGeneral Wiring, Lighting
05/13/2025CompleteAnco Electl Contctng—
12/23/2024Permit IssuedA & S ElectricGeneral Wiring
08/27/2024CompleteAnco Electl Contctng—
08/28/2023CompleteLerco ElectricGeneral Wiring
07/03/2023CompleteGemini Electric Co—
06/02/2023Permit IssuedA & S ElectricGeneral Wiring
01/16/2023Permit IssuedHexagon Construction & Electrical GroupGeneral Wiring
10/20/2022CompleteCharan Electrical Enterp's—
10/12/2022CompleteMac Fhionnghaile & Sons—
08/08/2022Permit IssuedGemini Electric CoGeneral Wiring
06/10/2022CompleteAnco Electl ContctngGeneral Wiring
10/08/2021CompleteStanco System Electrical Cont—
1 project · most recent 08/05/2025
Steel
FiledStatusContractorScope
08/05/2025Permit IssuedWDFSteel
1 project · most recent 07/02/2026
Fence
FiledStatusContractorScope
07/02/2026Permit IssuedWDFFence
▾Special Inspection Requirements (DOB NOW) — 50
DateRequirementInspectorRole
08/06/2025FinalGEORGE GHEBRYALprogress
08/06/2025Mechanical SystemsJAMES WILSONspecial
08/06/2025Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
08/06/2025FinalGEORGE GHEBRYALprogress
08/06/2025Energy Code Compliance InspectionsJAMES WILSONprogress
08/06/2025Maintenance informationJAMES WILSONenergy_progress
08/06/2025Interior lighting powerJAMES WILSONenergy_progress
08/06/2025Shutoff dampersJAMES WILSONenergy_progress
08/06/2025HVAC-R and service water heating system controlsJAMES WILSONenergy_progress
08/06/2025Duct leakage testing, insulation and designJAMES WILSONenergy_progress
08/06/2025HVAC-R and service water piping design and insulationJAMES WILSONenergy_progress
08/06/2025Electrical motors and elevatorsJAMES WILSONenergy_progress
08/06/2025HVAC-R and service water heating equipmentJAMES WILSONenergy_progress
08/06/2025Mastic and Intumescent Fire-resistant CoatingsGEORGE GHEBRYALspecial
08/06/2025Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
08/06/2025Fire-Resistance Rated ConstructionGEORGE GHEBRYALprogress
08/06/2025Energy Code Compliance InspectionsJAMES WILSONprogress
08/06/2025Fenestration and door U-factor and product ratingsJAMES WILSONenergy_progress
08/06/2025Fenestration air leakageJAMES WILSONenergy_progress
08/06/2025Fenestration areasJAMES WILSONenergy_progress
08/06/2025Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
08/06/2025Structural Steel - High Strength BoltingGEORGE GHEBRYALspecial
08/06/2025Structural Steel - DetailsGEORGE GHEBRYALspecial
08/06/2025Structural Steel - WeldingGEORGE GHEBRYALspecial
08/06/2025Structural Stability – Alterations of existing buildingsGEORGE GHEBRYALspecial
Latest 25 of 50.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
P. S. 5EducationCellar, Floor 1, Roof
Project X01285891 Alteration · Permit Entire · 11/20/2025
Project X01165593 Alteration · Permit Entire · 01/15/2025
Project X01085184 Alteration · Permit Entire · 08/05/2024
Project X08005511 Alteration · LOC Issued · 09/20/2022
Project X07993295 Alteration · LOC Issued · 09/02/2022
New York City School Construction AuthorityGovernment / CivicFloor 1, Roof
Project X01274868 Alteration · Permit Entire · 09/04/2025
P.S. 5XEducation—
Project X01219911 Alteration · LOC Issued · 05/14/2025
Project X07993293 Alteration · LOC Issued · 09/02/2022
Project X07993296 Alteration · LOC Issued · 09/02/2022
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 174 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch17
08/24/2026X07993296-I1Request digital key ↗
08/24/2026X07993293-I1Request digital key ↗
08/24/2026X07993295-I1Request digital key ↗
Showing 3 of 17 on file for this type
▸Applications & Permits2
▸BISWORK PERMIT APPLICATION1
02/04/2013220251439Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
01/31/2013220251439Open ↗
▸Seals & Professional Certifications64
▸DOB NOWProgress Inspector Seal & Signature32
10/19/2026X01085184-P1Open ↗
10/19/2026X01085184-P1Open ↗
10/19/2026X01085184-P1Open ↗
Showing 3 of 32 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature17
08/24/2026X07993296-I1Open ↗
08/19/2026X01165593-P1Open ↗
08/19/2026X01165593-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
10/19/2026X01085184-P1Open ↗
10/09/2026X01085184-S1Open ↗
10/09/2026X01085184-S1Open ↗
Showing 3 of 10 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
04/25/2013220251439Open ↗
02/04/2013220251439Open ↗
01/31/2013220251439Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
01/31/2013220251439Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
01/31/2013220251439Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING1
01/31/2013220251439Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
03/11/2013220251439Open ↗
▸Safety & Tenant Protection7
▸DOB NOWNYCSCA - Approved Site Safety Plans7
08/18/2026X01274868-P1Open ↗
08/13/2026X07993296-I1Open ↗
08/13/2026X07993293-I1Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
08/13/2026X01085184-I1Open ↗
08/13/2026X01085184-S1Open ↗
08/13/2026X01085184-S3Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
01/31/2013220251439Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
04/25/2013220251439Open ↗
01/31/2013220251439Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
04/25/2013220251439Open ↗
▸BISTR8: Energy Code Progress Inspections1
02/04/2013220251439Open ↗
▸Approvals, Objections & Sign-offs46
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)18
08/18/2026X01085184-S3Open ↗
08/18/2026X01085184-I1Open ↗
08/18/2026X01085184-S1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter17
08/19/2026X01219911-I1Open ↗
08/18/2026X01085184-S3Open ↗
08/18/2026X01085184-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)5
08/13/2026X01219911-I1Open ↗
08/13/2026X07993293-I1Open ↗
08/13/2026X07993295-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDEP Variance (V5) letter3
08/13/2026X01085184-I1Open ↗
08/13/2026X01165593-I1Open ↗
08/13/2026X01085184-S3Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
04/25/2013220251439Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
04/25/2013220251439Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
01/31/2013220251439Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
04/25/2013220251439Open ↗
01/31/2013220251439Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
01/31/2013220251439Open ↗
▸Other Documents24
▸DOB NOWNYCSCA - BCC Plan Examination Transmittal19
08/18/2026X01085184-S3Open ↗
08/18/2026X01085184-I1Open ↗
08/18/2026X01085184-S1Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWNYCSCA Exhibit 25
08/13/2026X07993293-I1Open ↗
08/13/2026X01219911-I1Open ↗
08/13/2026X07993295-I1Open ↗
Showing 3 of 5 on file for this type