← Back
Two family brick
566 HENRY STREET
BROOKLYN · BIN 3004898
💬 Discuss this project
1900Year Built
3Stories
B1Building Class
R6BZoning
3,761 sfGross Floor Area
2Units
Rent Stabilized2 Open Violations ▸
Two family brick · 1,750 sf lot · 2.15 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Roof11p · 2 filings · 20 docs
Floor 34p · 1 filing · 20 docs
Floor 24p · 1 filing · 20 docs
Floor 17p · 2 filings · 20 docs
Cellar9p · 3 filings · 20 docs
Basement3p · 1 filing · 20 docs
1 job · most recent 08/25/2023
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/25/2023Signed-offSCALI CONSTRUCTION INCVentilation Systems
Ventilation
Panasonic FV-0510VS1 50 CFM · Exhaust Fan ×7
2 jobs · most recent 09/28/2022
General Wiring
FiledStatusContractorScope
09/28/2022CompleteHIGH QUALITY ELECTRIC OF—
01/11/2022CompleteACCURATE ELEC'L CONSTR &General Wiring
Building Lifecycle
All (117)Filed (17)Permit Issued (15)Signed Off (9)Violation (35)Inspection (11)Special Inspection (30)
11/24/2025
Violation issued (HPD, open)
I
12/04/2024
Violation issued (HPD, open)
I
03/22/2024
Filed — Alteration
B01023723-I1
03/22/2024
Permit issued — Supported Scaffold
B01023723-I1-SF
11/22/2023
Violation issued (HPD, closed)
I
09/05/2023
Signed off — Alteration CO
Application is filed for interior renovation to existing 4 story w/ cellar 4 family building to a 2 family building. Horizontal enlargement at first floor REAR, and enclosure of all shaft ways on all floors.
B00543418-I1
09/01/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Oscar Walters Jr
09/01/2023
Special inspection requirement — Fenestration air leakage
Oscar Walters Jr
09/01/2023
Special inspection requirement — HVAC-R and service water heating equipment
Oscar Walters Jr
09/01/2023
Special inspection requirement — Fireplaces
Oscar Walters Jr
09/01/2023
Special inspection requirement — Insulation placement and R values
Oscar Walters Jr
09/01/2023
Special inspection requirement — Fenestration areas
Oscar Walters Jr
09/01/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Paul Raymond
09/01/2023
Special inspection requirement — Mechanical Systems
Oscar Walters Jr
09/01/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Oscar Walters Jr
09/01/2023
Special inspection requirement — HVAC-R and service water heating system controls
Oscar Walters Jr
09/01/2023
Special inspection requirement — Permanent certificate
Oscar Walters Jr
09/01/2023
Special inspection requirement — Duct leakage testing, insulation and design
Oscar Walters Jr
09/01/2023
Special inspection requirement — Maintenance information
Oscar Walters Jr
09/01/2023
Special inspection requirement — Interior lighting power
Oscar Walters Jr
09/01/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Oscar Walters Jr
09/01/2023
Special inspection requirement — Masonry
Oscar Walters Jr
09/01/2023
Special inspection requirement — Concrete - Cast-In-Place
Oscar Walters Jr
09/01/2023
Special inspection requirement — Subgrade Inspections
Oscar Walters Jr
09/01/2023
Special inspection requirement — Fire-Resistance Rated Construction
Oscar Walters Jr
09/01/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Oscar Walters Jr
09/01/2023
Special inspection requirement — Final
Oscar Walters Jr
09/01/2023
Special inspection requirement — Energy Code Compliance Inspections
Oscar Walters Jr
08/25/2023
Filed — Alteration CO
Application is filed for interior renovation to existing 4 story w/ cellar 4 family building to a 2 family building. Horizontal enlargement at first floor REAR, and enclosure of all shaft ways on all floors.
B00543418-P3
06/26/2023
Signed off — Alteration
B00634920-I1
06/21/2023
Signed off — Alteration
B00543421-I1
05/25/2023
Signed off — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B00872234-I1
05/19/2023
Filed — Alteration
B00543421-P3
05/19/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Oscar Walters Jr
05/19/2023
Special inspection requirement — Permanent certificate
Oscar Walters Jr
05/19/2023
Special inspection requirement — HVAC-R and service water heating equipment
Oscar Walters Jr
05/19/2023
Special inspection requirement — Maintenance information
Oscar Walters Jr
05/19/2023
Special inspection requirement — Energy Code Compliance Inspections
Oscar Walters Jr
05/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Oscar Walters Jr
05/19/2023
Special inspection requirement — HVAC-R and service water heating system controls
Oscar Walters Jr
05/15/2023
Filed — Alteration CO
Application is filed for interior renovation to existing 4 story w/ cellar 4 family building to a 2 family building. Horizontal enlargement at first floor REAR, and enclosure of all shaft ways on all floors.
B00543418-P2
05/15/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/12/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
05/11/2023
Permit issued — Supported Scaffold
B00872234-I1-SF
05/10/2023
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B00872234-I1
05/09/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/04/2023
Signed off — Alteration CO
Application is filed for interior renovation to existing 4 story w/ cellar 4 family building to a 2 family building. Horizontal enlargement at first floor REAR, and enclosure of all shaft ways on all floors.
B00543418-S1
05/03/2023
Permit issued — Plumbing
B00634920-I1-EW-SP
05/03/2023
Permit issued — Plumbing
B00543421-I1-PL
05/03/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/17/2023
Signed off — Alteration
B00583644-I1
03/23/2023
Violation issued (HPD, closed)
A
03/21/2023
Signed off — Alteration
Interior demolition to existing 4 story, 4 family residence
B00588291-I1
03/21/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/10/2023
Filed — Alteration
B00543421-P2
03/10/2023
Filed — Alteration CO
Application is filed for interior renovation to existing 4 story w/ cellar 4 family building to a 2 family building. Horizontal enlargement at first floor REAR, and enclosure of all shaft ways on all floors.
B00543418-P1
02/27/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Paul Raymond
02/06/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
01/17/2023
Signed off — Alteration
B07997437-I1
01/17/2023
Signed off — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B07997417-I1
Latest 60 of 117 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BILLY ENTERPRISES1407/08/2026
SCALI CONSTRUCTION1707/08/2026
OWNER OF PREMISES 566 HEN103/22/2026
OWNER OF 566 HENRY STREET103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/06/2024$6.6M—— → —$1,755/sf building
07/30/2021$2.9M—Private party → 566 HENRY STREET LLC$771/sf building
09/21/2018$2.9M—Private party → Private party$776/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MJE PROFESSIONAL SERVICES203/22/2024
THINK DESIGN ARCHITECTURE1208/25/2023
ENTHINK ENGINEERS LLC209/07/2022
DESIGN BUILD SI, INC.102/07/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A+ EXPEDITING INC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SCALI CONSTRUCTION INCGeneral Contractor1707/08/2026
BILLY ENTERPRISES INCGeneral Contractor607/08/2026
PLUMBING NYC INCPlumbing407/08/2026
PLUMBING NYC, INCFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DEMERARA ENGINEERING, PLL4248908/25/2023
THINK DESIGN ARCHITECTURA683203/11/2022
DESIGN BUILD, SI, INC6114102/07/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupported ScaffoldPermit IssuedBILLY ENTERPRISES INC03/22/2024
DOB NOWSupported ScaffoldSigned-offBILLY ENTERPRISES INC05/11/2023
DOB NOWPlumbingSigned-offPLUMBING NYC, INC05/03/2023
DOB NOWPlumbingSigned-offPLUMBING WORKS NYC INC05/03/2023
DOB NOWConstruction FenceSigned-offSCALI CONSTRUCTION INC09/13/2022
DOB NOWSidewalk ShedSigned-offBILLY ENTERPRISES INC09/08/2022
DOB NOWSupported ScaffoldSigned-offBILLY ENTERPRISES INC09/08/2022
DOB NOWSprinklersSigned-offPLUMBING WORKS NYC INC06/28/2022
DOB NOWStructuralSigned-offSCALI CONSTRUCTION INC06/13/2022
DOB NOWGeneral ConstructionSigned-offSCALI CONSTRUCTION INC05/18/2022
DOB NOWMechanical SystemsPermit IssuedSCALI CONSTRUCTION INC05/18/2022
DOB NOWPlumbingSigned-offPLUMBING WORKS NYC INC01/12/2022
DOB NOWMechanical SystemsPermit IssuedSCALI CONSTRUCTION INC12/21/2021
DOB NOWConstruction FenceSigned-offSCALI CONSTRUCTION INC09/14/2021
DOB NOWGeneral ConstructionSigned-offSCALI CONSTRUCTION INC09/14/2021
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
05/15/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/12/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
05/09/2023Pass-Final CND-Occupancy InspectionPassView ↗
05/03/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/21/2023Pass-Final General Construction Non-Directive 14PassView ↗
02/06/2023Fail-Final General Construction Non-Directive 14FailView ↗
07/01/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/01/2022Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/01/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/25/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/25/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 67
DateRequirementInspectorRole
09/01/2023Permanent certificateOscar Walters Jrenergy_progress
09/01/2023Insulation placement and R valuesOscar Walters Jrenergy_progress
09/01/2023Fire-Resistance Rated ConstructionOscar Walters Jrprogress
09/01/2023Duct leakage testing, insulation and designOscar Walters Jrenergy_progress
09/01/2023Maintenance informationOscar Walters Jrenergy_progress
09/01/2023HVAC-R and service water heating system controlsOscar Walters Jrenergy_progress
09/01/2023HVAC-R and service water piping design and insulationOscar Walters Jrenergy_progress
09/01/2023FireplacesOscar Walters Jrenergy_progress
09/01/2023Interior lighting powerOscar Walters Jrenergy_progress
09/01/2023Fenestration air leakageOscar Walters Jrenergy_progress
09/01/2023Fenestration areasOscar Walters Jrenergy_progress
09/01/2023HVAC-R and service water heating equipmentOscar Walters Jrenergy_progress
09/01/2023Fire-Resistant Penetrations and JointsOscar Walters Jrspecial
09/01/2023Fenestration and door U-factor and product ratingsOscar Walters Jrenergy_progress
09/01/2023FinalOscar Walters Jrprogress
09/01/2023Energy Code Compliance InspectionsOscar Walters Jrprogress
09/01/2023MasonryOscar Walters Jrspecial
09/01/2023Structural Stability – Alterations of existing buildingsOscar Walters Jrspecial
09/01/2023Concrete - Cast-In-PlaceOscar Walters Jrspecial
09/01/2023Subgrade InspectionsOscar Walters Jrspecial
09/01/2023Mechanical SystemsOscar Walters Jrspecial
09/01/2023Subsurface Investigations (Borings/Test Pits)Paul Raymondspecial
05/19/2023Fire-Resistant Penetrations and JointsOscar Walters Jrspecial
05/19/2023Energy Code Compliance InspectionsOscar Walters Jrprogress
05/19/2023Maintenance informationOscar Walters Jrenergy_progress
Latest 25 of 67.
▾Documents — 135 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch17
09/01/2026B00583644-I1Request digital key ↗
09/01/2026B00588291-I1Request digital key ↗
09/01/2026B00588291-P1Request digital key ↗
Showing 3 of 17 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION6
10/28/2022340828215Open ↗
11/16/2021340828215Open ↗
08/24/2021321951474Open ↗
Showing 3 of 6 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation1
11/16/2021340828215Open ↗
▸Zoning, Tax Lot & Property Records12
▸DOB NOWZD1: DOB Zoning Diagram4
08/13/2026B00543418-P2Open ↗
08/13/2026B00543418-I1Open ↗
08/13/2026B00543418-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)4
08/13/2026B00543418-P1Open ↗
08/13/2026B00543418-P3Open ↗
08/13/2026B00543418-P2Open ↗
Showing 3 of 4 on file for this type
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
09/24/2019321951474Open ↗
▸BISZONING DIAGRAM1
12/02/2019321951474Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
09/24/2019321951474Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00543418-I1Open ↗
▸Seals & Professional Certifications42
▸DOB NOWDPL-1: Design Professional Seal & Signature17
09/01/2026B00583644-I1Open ↗
09/01/2026B00588291-P1Open ↗
09/01/2026B00588291-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/27/2026B00543421-P3Open ↗
09/27/2026B00543421-P3Open ↗
09/01/2026B00543418-P1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/27/2026B00543421-P3Open ↗
09/01/2026B00543418-P1Open ↗
09/01/2026B00543418-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
06/25/2019321951474Open ↗
06/25/2019321951474Open ↗
05/30/2019321951474Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
11/16/2021340828215Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/16/2021340828215Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
09/03/2019321951474Open ↗
05/30/2019321951474Open ↗
▸Safety & Tenant Protection9
▸DOB NOWStreet Tree Checklist4
08/27/2026B00543418-P3Open ↗
08/27/2026B00543418-P2Open ↗
08/27/2026B00543418-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTenant Protection Plan and Notes1
05/30/2019321951474Open ↗
▸BISSTREET TREES SITE PLAN1
07/24/2023340828215Open ↗
▸BISBPP: STREET TREES SITE PLAN1
11/16/2021340828215Open ↗
▸BISSTREET TREE CHECKLIST1
11/16/2021340828215Open ↗
▸BISSTREET TREE SIGNOFF1
07/24/2023340828215Open ↗
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
09/01/2026B00588291-I1Open ↗
09/01/2026B00588291-P1Open ↗
09/01/2026B00543421-I1Open ↗
Showing 3 of 12 on file for this type
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00543421-I1Open ↗
08/13/2026B00543418-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
05/30/2019321951474Open ↗
▸Inspections & Test Reports7
▸DOB NOWSOIL REPORT4
08/13/2026B00543418-P3Open ↗
08/13/2026B00543418-P2Open ↗
08/13/2026B00543418-P1Open ↗
Showing 3 of 4 on file for this type
▸BISSOIL REPORT1
06/25/2019321951474Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00543418-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00543418-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
12/30/2020321951474Open ↗
▸BISLETTERS - APPRVD FAB CERT-INTENT1
06/25/2019321951474Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT1
05/30/2019321951474Open ↗
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026B00543418-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026B00543418-I1Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION1
11/07/2022340828215Open ↗
▸BISEFILING COVER SHEET1
05/30/2019321951474Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
11/16/2021340828215Open ↗
▸Other Documents16
▸DOB NOWSite Survey: Initial4
08/13/2026B00543418-I1Open ↗
08/13/2026B00543418-P1Open ↗
08/13/2026B00543418-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026B00543418-P3Open ↗
08/13/2026B00543418-P1Open ↗
08/13/2026B00543418-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlot Diagram4
08/13/2026B00543418-P3Open ↗
08/13/2026B00543418-P2Open ↗
08/13/2026B00543418-P1Open ↗
Showing 3 of 4 on file for this type
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
11/07/2022340828215Open ↗
▸BISPLOT DIAGRAM1
09/06/2019321951474Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00543418-I1Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026B00543418-I1Open ↗