← Back
Two family brick
567 EAST 81 STREET
BROOKLYN · BIN 3222599
💬 Discuss this project
1960Year Built
3Stories
B1Building Class
R5BZoning
2,304 sfGross Floor Area
2Units
1 Open Violation ▸
Two family brick · 1,800 sf lot · 1.28 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectrical
Permit Issued — active, not yet Signed-off
RoofUnder Construction3p · 1 filing · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/31/2025$1.1M—Private party → Private party$456/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NKM ENGINEERING PLLC105/14/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SOLAR ONE INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244105/14/2026
Building Lifecycle
All (10)Filed (1)Permit Issued (1)Violation (3)Special Inspection (5)
06/15/2026
Permit issued — Solar
B01377595-I1-SL
05/14/2026
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
B01377595-I1
03/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
03/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
03/24/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
03/24/2026
Special inspection requirement — Final
NARESH MAHANGU
03/24/2026
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
01/08/2025
Violation issued (HPD, closed)
A
01/08/2025
Violation issued (HPD, closed)
A
01/08/2025
Violation issued (HPD, open)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSOLAR ONE INC06/15/2026
1 project · most recent 05/13/2026
FiledStatusContractorScope
05/13/2026CompleteNEWGRANGE ELECTRIC, INC—
1 project · most recent 05/14/2026
FiledStatusContractorScope
05/14/2026Permit IssuedSOLAR ONE INC13 panels, 5.72 kw, 742.99 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/24/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
03/24/2026Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
03/24/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
03/24/2026FinalNARESH MAHANGUprogress
03/24/2026Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/17/2026B01377595-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/29/2026B01377595-I1Open ↗
08/29/2026B01377595-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/17/2026B01377595-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/29/2026B01377595-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/17/2026B01377595-I1Open ↗