← Back
Miscellaneous two family
568 54 STREET
BROOKLYN · BIN 3014676
💬 Discuss this project
1910Year Built
2Stories
B9Building Class
R6BZoning
3,012 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Miscellaneous two family · 2,003 sf lot · 1.5 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Roof1p · 1 filing · 18 docs
Floor 31p · 1 filing · 18 docs
Floor 22p · 2 filings · 20 docs
Floor 12p · 2 filings · 20 docs
Cellar3p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/21/2021$1.4M—Private party → Private party$465/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JX FLAME SOLUTION INC706/17/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
VIBEN BUILDING1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NY BUILDING ASSOCIATES INGeneral Contractor203/21/2026
CASE PLUMBING LLCFire Protection107/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244606/17/2022
Building Lifecycle
All (58)Filed (7)Permit Issued (3)Signed Off (2)Violation (2)Inspection (6)Objection (8)Special Inspection (30)
07/30/2023
Violation issued (HPD, open)
A
10/03/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/28/2022
Signed off — Alteration
FILE SPRINKLER WORK TYPE IN CONJUNCTION WITH GENERAL CONSTRUCTION JOB#B00580528. INSTALL SPRINKLER SYSTEMS AT CELLAR 1ST 2ND AND 3RD FLOOR.
B00621611-I1
06/28/2022
Signed off — Alteration
FILE PLUMBING WORK TYPE. INSTALL NEW PLUMBING FIXTURES AT CELLAR 1ST 2ND AND 3RD FLOOR.
B00603717-I1
06/17/2022
Filed — Alteration
FILE PLUMBING WORK TYPE. INSTALL NEW PLUMBING FIXTURES AT CELLAR 1ST 2ND AND 3RD FLOOR.
B00603717-P2
06/17/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
06/17/2022
Special inspection requirement — HVAC-R and service water heating equipment
NARESH MAHANGU
06/17/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
06/17/2022
Special inspection requirement — HVAC-R and service water heating system controls
NARESH MAHANGU
05/17/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/05/2022
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/04/2022
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
04/22/2022
Permit issued — Sprinklers
B00621611-I1-EW-SP
04/04/2022
Special inspection requirement — Concrete - Cast-In-Place
NARESH MAHANGU
04/04/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
04/04/2022
Special inspection requirement — Structural Steel - Details
NARESH MAHANGU
04/04/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
04/04/2022
Special inspection requirement — Final
JIE ZHU
04/04/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
NARESH MAHANGU
04/04/2022
Special inspection requirement — Insulation placement and R values
NARESH MAHANGU
04/04/2022
Special inspection requirement — Fenestration areas
NARESH MAHANGU
04/04/2022
Special inspection requirement — Fenestration air leakage
NARESH MAHANGU
03/31/2022
Objection raised — Other
03/31/2022
Objection resolved — Addressed
03/29/2022
Filed — Alteration CO
RENOVATION OF AN EXISTING BUILDING AT CELLAR, 1ST, 2ND AND 3RD FLOOR. CONVENT EXISTING 2 FAMILY TO 3 FAMILY.OBTAIN NEW 3 FAMILY C OF O.
B00580528-P1
03/29/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
03/29/2022
Special inspection requirement — Structural Steel - Details
NARESH MAHANGU
03/29/2022
Special inspection requirement — Final
JIE ZHU
03/29/2022
Special inspection requirement — Insulation placement and R values
NARESH MAHANGU
03/29/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
NARESH MAHANGU
03/29/2022
Special inspection requirement — Fenestration air leakage
NARESH MAHANGU
03/29/2022
Special inspection requirement — Fenestration areas
NARESH MAHANGU
03/29/2022
Special inspection requirement — Concrete - Cast-In-Place
NARESH MAHANGU
03/29/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
02/22/2022
Filed — Alteration
FILE PLUMBING WORK TYPE. INSTALL NEW PLUMBING FIXTURES AT CELLAR 1ST 2ND AND 3RD FLOOR.
B00603717-P1
02/22/2022
Special inspection requirement — HVAC-R and service water heating system controls
NARESH MAHANGU
02/22/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
02/22/2022
Special inspection requirement — HVAC-R and service water heating equipment
NARESH MAHANGU
02/22/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
02/02/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
01/26/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/30/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
11/30/2021
Special inspection requirement — Sprinkler Systems
NARESH MAHANGU
11/29/2021
Filed — Alteration
FILE SPRINKLER WORK TYPE IN CONJUNCTION WITH GENERAL CONSTRUCTION JOB#B00580528. INSTALL SPRINKLER SYSTEMS AT CELLAR 1ST 2ND AND 3RD FLOOR.
B00621611-P1
11/29/2021
Special inspection requirement — Sprinkler Systems
11/29/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/09/2021
Violation issued (ECB, closed)
Construction
11/05/2021
Objection raised — Structural
11/05/2021
Objection resolved — Addressed
11/05/2021
Objection raised — Structural
11/05/2021
Objection resolved — Addressed
11/02/2021
Filed — Alteration
FILE SPRINKLER WORK TYPE IN CONJUNCTION WITH GENERAL CONSTRUCTION JOB#B00580528. INSTALL SPRINKLER SYSTEMS AT CELLAR 1ST 2ND AND 3RD FLOOR.
B00621611-I1
10/27/2021
Permit issued — Plumbing
B00603717-I1-PL
10/05/2021
Filed — Alteration
FILE PLUMBING WORK TYPE. INSTALL NEW PLUMBING FIXTURES AT CELLAR 1ST 2ND AND 3RD FLOOR.
B00603717-I1
09/30/2021
Permit issued — Structural
B00580528-I1-GC-CX
09/08/2021
Objection resolved — Addressed
08/31/2021
Objection raised — Zoning
08/30/2021
Filed — Alteration CO
RENOVATION OF AN EXISTING BUILDING AT CELLAR, 1ST, 2ND AND 3RD FLOOR. CONVENT EXISTING 2 FAMILY TO 3 FAMILY.OBTAIN NEW 3 FAMILY C OF O.
B00580528-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offS & L PLUMBING INC04/22/2022
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC10/27/2021
DOB NOWStructuralPermit IssuedNY BUILDING ASSOCIATES IN09/30/2021
1 project · most recent 08/30/2022
General Wiring
FiledStatusContractorScope
08/30/2022CompleteA.C. MORGAN ELECTRICGeneral Wiring
1 project · most recent 03/29/2022
Steel
FiledStatusContractorScope
03/29/2022Permit IssuedNY BUILDING ASSOCIATES INSteel
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
10/03/2022Pass-Final CND-Occupancy InspectionPassView ↗
05/17/2022Pass-Final CND-Occupancy InspectionPassView ↗
05/05/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/04/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/02/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/26/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
06/17/2022Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
06/17/2022HVAC-R and service water heating equipmentNARESH MAHANGUenergy_progress
06/17/2022HVAC-R and service water piping design and insulationNARESH MAHANGUenergy_progress
06/17/2022HVAC-R and service water heating system controlsNARESH MAHANGUenergy_progress
04/04/2022Concrete - Cast-In-PlaceNARESH MAHANGUspecial
04/04/2022Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
04/04/2022Structural Steel - DetailsNARESH MAHANGUspecial
04/04/2022Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
04/04/2022FinalJIE ZHUprogress
04/04/2022Fenestration and door U-factor and product ratingsNARESH MAHANGUenergy_progress
04/04/2022Insulation placement and R valuesNARESH MAHANGUenergy_progress
04/04/2022Fenestration areasNARESH MAHANGUenergy_progress
04/04/2022Fenestration air leakageNARESH MAHANGUenergy_progress
03/29/2022Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
03/29/2022Structural Steel - DetailsNARESH MAHANGUspecial
03/29/2022FinalJIE ZHUprogress
03/29/2022Insulation placement and R valuesNARESH MAHANGUenergy_progress
03/29/2022Fenestration and door U-factor and product ratingsNARESH MAHANGUenergy_progress
03/29/2022Fenestration air leakageNARESH MAHANGUenergy_progress
03/29/2022Fenestration areasNARESH MAHANGUenergy_progress
03/29/2022Concrete - Cast-In-PlaceNARESH MAHANGUspecial
03/29/2022Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
02/22/2022HVAC-R and service water heating system controlsNARESH MAHANGUenergy_progress
02/22/2022Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
02/22/2022HVAC-R and service water heating equipmentNARESH MAHANGUenergy_progress
Latest 25 of 30.
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
09/01/2026B00603717-I1Request digital key ↗
09/01/2026B00603717-P1Request digital key ↗
09/01/2026B00603717-P2Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00580528-I1Open ↗
▸Seals & Professional Certifications18
▸DOB NOWDPL-1: Design Professional Seal & Signature7
09/01/2026B00603717-I1Open ↗
09/01/2026B00603717-P1Open ↗
09/01/2026B00603717-P2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B00603717-I1Open ↗
08/30/2026B00580528-I1Open ↗
08/30/2026B00580528-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/23/2026B00621611-I1Open ↗
09/01/2026B00603717-I1Open ↗
08/30/2026B00580528-I1Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/15/2026B00580528-I1Open ↗
08/15/2026B00580528-P1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/01/2026B00603717-P2Open ↗
09/01/2026B00603717-I1Open ↗
09/01/2026B00603717-P1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00603717-I1Open ↗
08/13/2026B00580528-I1Open ↗
▸Other Documents2
▸DOB NOWProperty Ownership Certification2
08/15/2026B00580528-I1Open ↗
08/15/2026B00580528-P1Open ↗