← Back
BuildNYC
General warehouse
57-00 49TH PLACE
QUEENS · Maspeth · BIN 4058972
💬 Discuss this project
1964Year Built
2Stories
E1Building Class
M3-1Zoning
66,900 sfGross Floor Area
1Units
LL97 Covered0 Active Violations
General warehouse · Owner of record: SPG 49th Place · 93,338 sf lot · 0.72 FAR built · Flood zone X500
Locations of Work
Mechanical
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofAAA Wholesale10p · 2 filings · 8 docs
Floor 1Seagis Property Group LP1 filing · 3 docs
MezzanineSeagis Property Group LP1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Seagis Property Group403/22/2026
AAA Wholesale of Maspeth 330209/13/2026
SPG 49th Place103/22/2026
Rensow Realty103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/12/2017$23.0M—RENSOW REALTY CORP. → SPG 49TH PLACE LLC$344/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Anb Engineering107/24/2026
SY Engineering108/27/2021
Advance Design Group106/03/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
K M DOB Consulting203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Urban GCGeneral Contractor303/21/2026
Green Home General ContGeneral Contractor107/30/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Hardie & Associates, Cons3760107/24/2026
SY Engineering5149108/27/2021
Building Lifecycle
All (44)Filed (3)Permit Issued (2)Violation (25)Objection (6)Special Inspection (8)
07/29/2026
Permit issued — Mechanical Systems
Q01415896-I1-MS
07/24/2026
Filed — Alteration
INSTALLATION OF 8 TRANE ROOFTOP MOUNTED UNITS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01415896-I1
07/24/2026
Special inspection requirement — Maintenance information
ELLIOTT HARDIE
07/24/2026
Special inspection requirement — HVAC-R and service water heating equipment
ELLIOTT HARDIE
07/24/2026
Special inspection requirement — HVAC-R and service water heating system controls
ELLIOTT HARDIE
07/24/2026
Special inspection requirement — Energy Code Compliance Inspections
ELLIOTT HARDIE
06/11/2026
Special inspection requirement — Final
ELLIOTT HARDIE
06/11/2026
Special inspection requirement — Mechanical Systems
ELLIOTT HARDIE
09/24/2021
Permit issued — Mechanical Systems
Q00570410-I1-MS
08/27/2021
Filed — Alteration
INSTALLATION OF ROOFTOP AC UNITS AND REFRIGERANT COMPRESSOR UNITS.
Q00570410-I1
06/08/2020
Objection raised — Structural
06/08/2020
Objection resolved — Addressed
06/08/2020
Objection raised — Other
06/08/2020
Objection resolved — Addressed
06/08/2020
Objection raised — Scope
06/08/2020
Objection resolved — Addressed
06/03/2020
Filed — Alteration
INSTALLATION OF AUTOMATIC DRY SPRINKLER SYSTEM THROUGHOUT THE BUILDING.
Q00354079-I1
06/03/2020
Special inspection requirement — Sprinkler Systems
06/03/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/02/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/02/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/02/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/02/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/07/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/02/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/02/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offGreen Home General Cont07/29/2026
DOB NOWMechanical SystemsSigned-offUrban GC09/24/2021
BISMHISSUEDWireless Network Group02/07/2018
BISMHISSUEDMidcounty Mechanical05/31/1991
BISPLISSUEDEconomy Plumbing & Heating Co05/10/1991
BISMHISSUEDMidcounty Mechanical10/23/1990
BISOTISSUEDMidcounty Mechanical06/25/1990
2 projects · most recent 07/24/2026
Air Conditioning Systems Heating and Air Conditioning Systems Refrigeration Systems
FiledStatusContractorScopeMake / Model / Capacity
07/24/2026Signed-offGreen Home General ContAir Conditioning Systems, Heating and Air Conditioning Systems
Cooling
Trane GBC240A3EMB0000 252,000 BTU · Rooftop Unit ×7
Heat / Cool
Trane GCC180A3EMA1DQY 194,000 BTU · Rooftop Unit ×1
08/27/2021Signed-offUrban GCAir Conditioning Systems, Refrigeration Systems
Cooling
Trane GBC240A3EMB07000 20 tons · Rooftop Unit ×7
Refrigeration
Heatcraft BCH0060MCACZA0100 80 kW · Refrigeration Unit ×2
HCH0220LCACDC0523 100 kW · Refrigeration Unit ×2
1 project · most recent 06/03/2020
FiledStatusContractorScope
06/03/2020———
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
07/24/2026Maintenance informationELLIOTT HARDIEenergy_progress
07/24/2026HVAC-R and service water heating equipmentELLIOTT HARDIEenergy_progress
07/24/2026HVAC-R and service water heating system controlsELLIOTT HARDIEenergy_progress
07/24/2026Energy Code Compliance InspectionsELLIOTT HARDIEprogress
06/11/2026FinalELLIOTT HARDIEprogress
06/11/2026Mechanical SystemsELLIOTT HARDIEspecial
06/03/2020Sprinkler Systems—special
06/03/2020Fire-Resistant Penetrations and Joints—special
▾Tenants in the building
TenantSpaceFloorsRenovation projects
AAA WholesaleIndustrial / WarehouseRoof
Project Q01415896 Alteration · Permit Entire · 07/24/2026
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 49 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch2
08/27/2026Q00570410-I1Request digital key ↗
08/16/2026Q01415896-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
08/14/2026Q00354079-I1Request digital key ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION5
04/24/2020410130157Open ↗
04/24/2020420097415Open ↗
12/15/2017421584887Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION1
02/08/2018421584887Open ↗
▸Seals & Professional Certifications13
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
04/03/2018421584887Open ↗
02/08/2018421584887Open ↗
02/08/2018421584887Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/28/2026Q00354079-I1Open ↗
08/16/2026Q01415896-I1Open ↗
08/13/2026Q00570410-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026Q01415896-I1Open ↗
08/28/2026Q01415896-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/15/2017421584887Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/15/2017421584887Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026Q01415896-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
02/24/2010420097415Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST2
01/06/2010420097415Open ↗
07/02/2008410130157Open ↗
▸Environmental & Asbestos5
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
01/06/2010420097415Open ↗
06/27/2008410130157Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/14/2026Q00354079-I1Open ↗
08/13/2026Q00570410-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/15/2017421584887Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
04/03/2018421584887Open ↗
02/08/2018421584887Open ↗
02/07/2018421584887Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
04/03/2018421584887Open ↗
▸Approvals, Objections & Sign-offs4
▸BISADMINISTRATIVE OBJECTIONS2
01/06/2010420097415Open ↗
06/27/2008410130157Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
03/02/2010420097415Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
04/11/2018421584887Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
04/03/2018421584887Open ↗
12/15/2017421584887Open ↗
01/06/2010420097415Open ↗
▸Filing & Intake Forms7
▸BISEFILING COVER SHEET3
12/15/2017421584887Open ↗
01/06/2010420097415Open ↗
06/27/2008410130157Open ↗
▸BISADDITIONAL INFORMATION2
01/30/2018421584887Open ↗
01/18/2018421584887Open ↗
▸BISBOROUGH INTAKE FORM2
04/24/2020410130157Open ↗
04/24/2020420097415Open ↗
▸Other Documents1
▸BISPlot Diagram1
02/25/2010420097415Open ↗