← Back
Two family converted from one family
57-32 157 STREET
QUEENS · Queensboro Hill · BIN 4489046
💬 Discuss this project
1950Year Built
2Stories
B3Building Class
R3XZoning
2,397 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 4,000 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/01/2023$1.8M—LUCKY 157 LLC → Private party$730/sf building
02/05/2021$890K—Private party → LUCKY 157 LLC$371/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ZHENG & ASSOCIATES LLC208/10/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW YORK CONSTRUCTION MA*General Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ZHENG & ASSOCIATES LLC7330208/10/2022
Building Lifecycle
All (16)Filed (2)Permit Issued (1)Signed Off (1)Inspection (2)Special Inspection (10)
08/16/2022
Signed off — Alteration
RENOVATION FOR EXISTING ONE CAR GARAGE. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
Q00559212-I1
08/12/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/10/2022
Filed — Alteration
RENOVATION FOR EXISTING ONE CAR GARAGE. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
Q00559212-P1
08/10/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jinfar Liu
08/10/2022
Special inspection requirement — Energy Code Compliance Inspections
Jinfar Liu
08/10/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Jinfar Liu
08/10/2022
Special inspection requirement — Fenestration air leakage
Jinfar Liu
08/10/2022
Special inspection requirement — Fenestration areas
Jinfar Liu
08/10/2022
Special inspection requirement — Fenestration air leakage
Jinfar Liu
08/10/2022
Special inspection requirement — Fenestration areas
Jinfar Liu
08/10/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Jinfar Liu
08/10/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jinfar Liu
08/10/2022
Special inspection requirement — Energy Code Compliance Inspections
Jinfar Liu
08/03/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
08/24/2021
Permit issued — General Construction
Q00559212-I1-GC
08/20/2021
Filed — Alteration
RENOVATION FOR EXISTING ONE CAR GARAGE. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
Q00559212-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNEW YORK CONSTRUCTION MA*08/24/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/12/2022Pass-Final General Construction Non-Directive 14PassView ↗
08/03/2022Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/10/2022Fire-Resistant Penetrations and JointsJinfar Liuspecial
08/10/2022Energy Code Compliance InspectionsJinfar Liuprogress
08/10/2022Fenestration and door U-factor and product ratingsJinfar Liuenergy_progress
08/10/2022Fenestration air leakageJinfar Liuenergy_progress
08/10/2022Fenestration areasJinfar Liuenergy_progress
08/10/2022Fenestration air leakageJinfar Liuenergy_progress
08/10/2022Fenestration areasJinfar Liuenergy_progress
08/10/2022Fenestration and door U-factor and product ratingsJinfar Liuenergy_progress
08/10/2022Fire-Resistant Penetrations and JointsJinfar Liuspecial
08/10/2022Energy Code Compliance InspectionsJinfar Liuprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026Q00559212-P1Request digital key ↗
08/27/2026Q00559212-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026Q00559212-P1Open ↗
09/01/2026Q00559212-P1Open ↗
08/26/2026Q00559212-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026Q00559212-P1Open ↗
08/27/2026Q00559212-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q00559212-P1Open ↗
08/26/2026Q00559212-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/27/2026Q00559212-P1Open ↗
08/27/2026Q00559212-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00559212-I1Open ↗