← Back
Miscellaneous two family
57-53 225 STREET
QUEENS · BIN 4161533
💬 Discuss this project
1965Year Built
2Stories
B9Building Class
R4-1Zoning
3,370 sfGross Floor Area
2Units
Miscellaneous two family · Owner of record: PK WONG BROTHERS LLC · 3,456 sf lot · 0.98 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 23p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
Cellar1p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/05/2025$1.5M—— → —$455/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHUN FENG, ARCHITECT404/22/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGH QUALITY 338403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LIK KAI CONSTRUCTION INCGeneral Contractor104/09/2026
AAA TOTAL PLUMBING, INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244404/22/2026
Building Lifecycle
All (27)Filed (4)Permit Issued (2)Signed Off (2)Inspection (1)Special Inspection (18)
07/27/2026
Signed off — Alteration
RENOVATION OF AN EXISTING RESIDENTIAL HOUSE ON CELLAR, 1ST AND 2ND FLOOR WITH REMOVING, PARTITIONING, PAINTING, REPAIRING, REPLACING AND INSTALLING WORKS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01343611-I1
07/27/2026
Signed off — Alteration
RENOVATION OF AN EXISTING RESIDENTIAL HOUSE ON CELLAR, 1ST AND 2ND FLOOR WITH REMOVING, PARTITIONING, PAINTING, REPAIRING, REPLACING AND INSTALLING WORKS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01343611-S1
04/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
04/23/2026
Special inspection requirement — Final
Chun Feng
04/23/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
04/23/2026
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
04/23/2026
Special inspection requirement — Fenestration areas
NARESH MAHANGU
04/23/2026
Special inspection requirement — Fenestration air leakage
NARESH MAHANGU
04/23/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
NARESH MAHANGU
04/23/2026
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
04/22/2026
Filed — Alteration
RENOVATION OF AN EXISTING RESIDENTIAL HOUSE ON CELLAR, 1ST AND 2ND FLOOR WITH REMOVING, PARTITIONING, PAINTING, REPAIRING, REPLACING AND INSTALLING WORKS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01343611-P1
04/22/2026
Filed — Alteration
RENOVATION OF AN EXISTING RESIDENTIAL HOUSE ON CELLAR, 1ST AND 2ND FLOOR WITH REMOVING, PARTITIONING, PAINTING, REPAIRING, REPLACING AND INSTALLING WORKS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01343611-P2
04/21/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
NARESH MAHANGU
04/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
04/21/2026
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
04/21/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
04/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
04/21/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
04/21/2026
Special inspection requirement — Final
Chun Feng
04/21/2026
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
04/21/2026
Special inspection requirement — Fenestration air leakage
NARESH MAHANGU
04/21/2026
Special inspection requirement — Fenestration areas
NARESH MAHANGU
02/23/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/03/2026
Permit issued — Plumbing
Q01343611-S1-PL
01/23/2026
Permit issued — General Construction
Q01343611-I1-GC
01/20/2026
Filed — Alteration
RENOVATION OF AN EXISTING RESIDENTIAL HOUSE ON CELLAR, 1ST AND 2ND FLOOR WITH REMOVING, PARTITIONING, PAINTING, REPAIRING, REPLACING AND INSTALLING WORKS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01343611-I1
01/20/2026
Filed — Alteration
RENOVATION OF AN EXISTING RESIDENTIAL HOUSE ON CELLAR, 1ST AND 2ND FLOOR WITH REMOVING, PARTITIONING, PAINTING, REPAIRING, REPLACING AND INSTALLING WORKS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01343611-S1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAAA TOTAL PLUMBING, INC02/03/2026
DOB NOWGeneral ConstructionSigned-offPARAMOUNT HOMES MANAGE01/23/2026
1 project · most recent 04/22/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/22/2026Signed-offAAA TOTAL PLUMBING, INCGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
02/23/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
04/23/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
04/23/2026FinalChun Fengprogress
04/23/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
04/23/2026Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
04/23/2026Fenestration areasNARESH MAHANGUenergy_progress
04/23/2026Fenestration air leakageNARESH MAHANGUenergy_progress
04/23/2026Fenestration and door U-factor and product ratingsNARESH MAHANGUenergy_progress
04/23/2026Air barrier - visual inspectionNARESH MAHANGUenergy_progress
04/21/2026Fenestration and door U-factor and product ratingsNARESH MAHANGUenergy_progress
04/21/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
04/21/2026Air barrier - visual inspectionNARESH MAHANGUenergy_progress
04/21/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
04/21/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
04/21/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
04/21/2026FinalChun Fengprogress
04/21/2026Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
04/21/2026Fenestration air leakageNARESH MAHANGUenergy_progress
04/21/2026Fenestration areasNARESH MAHANGUenergy_progress
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/17/2026Q01343611-I1Request digital key ↗
08/17/2026Q01343611-P2Request digital key ↗
08/17/2026Q01343611-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature7
08/31/2026Q01343611-I1Open ↗
08/31/2026Q01343611-I1Open ↗
08/31/2026Q01343611-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026Q01343611-P2Open ↗
08/17/2026Q01343611-P1Open ↗
08/13/2026Q01343611-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/31/2026Q01343611-I1Open ↗
08/25/2026Q01343611-P2Open ↗
08/24/2026Q01343611-P1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/17/2026Q01343611-P2Open ↗
08/17/2026Q01343611-P1Open ↗
08/13/2026Q01343611-S1Open ↗
Showing 3 of 4 on file for this type