← Back
Two family brick
57-64 75TH STREET
QUEENS · BIN 4621087
💬 Discuss this project
2024Year Built
3Stories
B1Building Class
R4-1Zoning
2,315 sfGross Floor Area
2Units
0 Open Violations
Two family brick · Owner of record: L AND ZX INC · 2,250 sf lot · 1.03 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbingFire Protection
Roof9p · 2 filings · 20 docs
Floor 33p · 1 filing · 20 docs
Floor 22p · 1 filing · 20 docs
Floor 14p · 1 filing · 20 docs
Cellar2p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MEGA GENERAL CONSTRUCTION403/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMERILAND BROOK LLC608/10/2026
MOMENTUM SOLAR107/27/2026
BRIAN ILL DEVELOPMENT LLC604/01/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AMERILAND BROOK LLC15061208/10/2026
MXV SIA LLC9281107/27/2026
Building Lifecycle
All (65)Filed (13)Permit Issued (1)Signed Off (3)Violation (4)Objection (14)Special Inspection (30)
08/10/2026
Filed — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-A1
08/07/2026
Signed off — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-S2
08/03/2026
Permit issued — Solar
Q01436678-I1-SL
07/31/2026
Special inspection requirement — Fenestration areas
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Permanent certificate
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — HVAC-R and service water heating system controls
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Structural Steel - Details
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Footing and Foundation
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — HVAC-R and service water heating equipment
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Insulation placement and R values
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Electric vehicle service equipment requirements
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Heating Systems
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
TONY ONYEAGORO
07/31/2026
Special inspection requirement — Fire-Resistance Rated Construction
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Fenestration air leakage
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Concrete - Cast-In-Place
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Structural Steel - High Strength Bolting
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Chimneys and vents
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Ventilation and air distribution system
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Masonry
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Mechanical Systems
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Structural Steel - Welding
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Subgrade Inspections
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Energy Code Compliance Inspections
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Final
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Metering
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Maintenance information
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Air barrier — testing
XIAOHONG ZHAO
07/31/2026
Special inspection requirement — Duct leakage testing, insulation and design
XIAOHONG ZHAO
07/27/2026
Filed — Alteration
Installation of solar panels, rooftop, grid tied, railed, 21 modules, 9.24 KW
Q01436678-I1
04/01/2026
Filed — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-P9
03/02/2026
Filed — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-P7
03/02/2026
Filed — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-P8
12/02/2025
Filed — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-P5
05/21/2025
Filed — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-P4
05/08/2025
Filed — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-P3
12/24/2024
Violation issued (ECB, closed)
Unknown
12/24/2024
Violation issued (ECB, closed)
Construction
12/24/2024
Violation issued (ECB, closed)
Construction
12/24/2024
Violation issued (ECB, closed)
Unknown
10/22/2024
Signed off — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-S6
09/11/2024
Filed — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-P2
09/06/2024
Filed — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-S6
09/04/2024
Signed off — Full Demolition
FULL DEMOLITION OF A TWO-STORY WITH CELLAR DETACHED HOUSE AT 57-64 75th STREET QUEENS NY 11379.
Q01043344-I1
05/15/2024
Objection resolved — Addressed
05/13/2024
Objection raised — Structural
04/30/2024
Filed — Full Demolition
FULL DEMOLITION OF A TWO-STORY WITH CELLAR DETACHED HOUSE AT 57-64 75th STREET QUEENS NY 11379.
Q01043344-I1
12/15/2022
Filed — New Building
FILE PL WORKTYPE IN CONJUNCTION WITH NB JOB#Q08052851
Q08052851-S2
12/15/2022
Objection raised — Zoning
12/15/2022
Objection resolved — Addressed
12/15/2022
Objection raised — Accessibility
12/15/2022
Objection resolved — Addressed
12/15/2022
Objection raised — Zoning
12/15/2022
Objection resolved — Addressed
12/15/2022
Objection raised — Zoning
12/15/2022
Objection resolved — Addressed
Latest 60 of 65 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedMOMENTUM SOLAR08/03/2026
1 project · most recent 08/10/2026
Associated Ducts and Piping Heating and Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
08/10/2026Signed-offMEGA GENERAL CONSTR NYCAssociated Ducts and Piping, Heating and Air Conditioning Systems, Heating Systems
Heat / Cool
Aux Cloud Commerce ASPR30HPMULO 30,000 BTU · Condensing Unit ×2
ASPR18HPMULO 17,700 BTU · Condensing Unit ×1
ASPR24HPMULO 24,000 BTU · Condensing Unit ×1
Heating
A.O. Smith E6-50H45DV 130 15,354 BTU · Water Heater ×2
Williamson GWA-100-N-T 100,000 BTU · Boiler ×6
Ducts & Piping
Delta Breeze SLIM50 50 CFM · Exhaust Fan ×12
Air King EB30BL 130 CFM · Kitchen Exhaust ×6
1 project · most recent 08/10/2026
Sprinkler System
FiledStatusContractorScope
08/10/2026——Sprinkler System
1 project · most recent 08/10/2026
Gas Plumbing-Sprinkler Storm Water/Sanitary
FiledStatusContractorScope
08/10/2026Signed-offAMERICAN STANDARD P&H CORGas, Plumbing-Sprinkler, Storm, Water/Sanitary
2 projects · most recent 07/27/2026
General Wiring
FiledStatusContractorScope
07/27/2026Permit IssuedISLAND ELECTRIC CORP—
01/28/2026CompleteR & T ELECTRICAL CORPGeneral Wiring
1 project · most recent 08/10/2026
Concrete Masonry
FiledStatusContractorScope
08/10/2026Signed-offMEGA GENERAL CONSTR NYCConcrete, Masonry
1 project · most recent 07/27/2026
FiledStatusContractorScope
07/27/2026Permit IssuedMOMENTUM SOLAR21 panels, 9.24 kw, 2,250 roof_area_sqft
1 project · most recent 08/10/2026
Earthwork
FiledStatusContractorScope
08/10/2026Signed-offMEGA GENERAL CONSTR NYCEarthwork
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
07/31/2026HVAC-R and service water heating system controlsXIAOHONG ZHAOenergy_progress
07/31/2026Electric vehicle service equipment requirementsXIAOHONG ZHAOenergy_progress
07/31/2026Ventilation and air distribution systemXIAOHONG ZHAOenergy_progress
07/31/2026Insulation placement and R valuesXIAOHONG ZHAOenergy_progress
07/31/2026Permanent certificateXIAOHONG ZHAOenergy_progress
07/31/2026HVAC-R and service water heating equipmentXIAOHONG ZHAOenergy_progress
07/31/2026Chimneys and ventsXIAOHONG ZHAOspecial
07/31/2026Concrete - Cast-In-PlaceXIAOHONG ZHAOspecial
07/31/2026Excavations - Sheeting, Shoring, and BracingXIAOHONG ZHAOspecial
07/31/2026Fire-Resistant Penetrations and JointsXIAOHONG ZHAOspecial
07/31/2026Heating SystemsXIAOHONG ZHAOspecial
07/31/2026MasonryXIAOHONG ZHAOspecial
07/31/2026Mechanical SystemsXIAOHONG ZHAOspecial
07/31/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationXIAOHONG ZHAOspecial
07/31/2026Structural Steel - DetailsXIAOHONG ZHAOspecial
07/31/2026Structural Steel - High Strength BoltingXIAOHONG ZHAOspecial
07/31/2026Structural Steel - WeldingXIAOHONG ZHAOspecial
07/31/2026Subgrade InspectionsXIAOHONG ZHAOspecial
07/31/2026Subsurface Investigations (Borings/Test Pits)TONY ONYEAGOROspecial
07/31/2026Energy Code Compliance InspectionsXIAOHONG ZHAOprogress
07/31/2026FinalXIAOHONG ZHAOprogress
07/31/2026Fire-Resistance Rated ConstructionXIAOHONG ZHAOprogress
07/31/2026Footing and FoundationXIAOHONG ZHAOprogress
07/31/2026MeteringXIAOHONG ZHAOenergy_progress
07/31/2026Maintenance informationXIAOHONG ZHAOenergy_progress
Latest 25 of 150.
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026Q01436678-I1Request digital key ↗
▸Seals & Professional Certifications52
▸DOB NOWSpecial Inspector Seal & Signature27
09/23/2026Q08052851-P3Open ↗
09/23/2026Q08052851-P3Open ↗
09/16/2026Q08052851-P4Open ↗
Showing 3 of 27 on file for this type
▸DOB NOWProgress Inspector Seal & Signature24
09/23/2026Q08052851-P3Open ↗
09/16/2026Q08052851-P4Open ↗
09/16/2026Q08052851-P4Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026Q01436678-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q08052851-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q08052851-I1Open ↗