← Back
One story retail building
57 EAST BURNSIDE AVENUE
BRONX · Mount Hope · BIN 2131177
💬 Discuss this project
1923Year Built
1Stories
K1Building Class
R8Zoning
21,000 sfGross Floor Area
2Units
7 Open Violations ▸
One story retail building · Owner of record: BURNSIDE PROPERTIES NY LLC · 23,000 sf lot · 0.91 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Permit Issued — active, not yet Signed-off
Floor 6Under Construction21p · 1 filing · 20 docs
Floor 5Under Construction21p · 1 filing · 20 docs
Floor 4Under Construction21p · 1 filing · 20 docs
Floor 3Under Construction21p · 1 filing · 20 docs
Floor 2Under Construction23p · 1 filing · 20 docs
Floor 1Under Construction27p · 1 filing · 20 docs
CellarUnder Construction24p · 1 filing · 20 docs
Site & exteriorUnder Construction20p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EXPRESS BUILDERS JB2110/03/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/28/2025$15.0M—— → —$714/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WEXLER ASSOCIATES303/18/2026
HIDAMARI ENGINEERING SERVICES, P.C.412/18/2025
NIKOLAI KATZ ARCHITECT110/17/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BAC Developers Group703/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EXPRESS BUILDERS JB, INCGeneral Contractor209/17/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
REGIONAL TESTING CORP.394103/18/2026
Building Lifecycle
All (53)Filed (8)Permit Issued (2)Objection (13)Special Inspection (30)
09/16/2026
Permit issued — General Construction
X01297399-I1-GC
09/10/2026
Permit issued — Support of Excavation
X01297399-S8-SE
08/12/2026
Objection resolved — Addressed
03/24/2026
Objection raised — Other
03/18/2026
Filed — New Building
MECHANICAL SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER X01297399-I1.
X01297399-S8
03/18/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Paul Raymond
03/18/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Paul Raymond
02/12/2026
Objection resolved — Addressed
01/20/2026
Objection resolved — Addressed
12/18/2025
Filed — New Building
MECHANICAL SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER X01297399-I1.
X01297399-S7
12/18/2025
Special inspection requirement — Standpipe Systems
12/16/2025
Objection resolved — Addressed
11/18/2025
Objection raised — Admin
11/18/2025
Objection raised — Other
11/18/2025
Objection raised — Admin
11/14/2025
Objection raised — Other
11/14/2025
Objection raised — Zoning
11/14/2025
Objection raised — Energy
11/13/2025
Objection raised — Zoning
11/13/2025
Objection raised — Admin
10/29/2025
Filed — New Building
MECHANICAL SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER X01297399-I1.
X01297399-S1
10/29/2025
Filed — New Building
MECHANICAL SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER X01297399-I1.
X01297399-S2
10/22/2025
Filed — New Building
MECHANICAL SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER X01297399-I1.
X01297399-S4
10/22/2025
Filed — New Building
MECHANICAL SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER X01297399-I1.
X01297399-S3
10/22/2025
Filed — New Building
MECHANICAL SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER X01297399-I1.
X01297399-S6
10/21/2025
Special inspection requirement — Energy Code Compliance Inspections
10/21/2025
Special inspection requirement — Final
10/21/2025
Special inspection requirement — HVAC-R and service water heating equipment
10/21/2025
Special inspection requirement — Maintenance information
10/21/2025
Special inspection requirement — Electrical motors and elevators
10/21/2025
Special inspection requirement — Shutoff dampers
10/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
10/21/2025
Special inspection requirement — HVAC-R and service water heating system controls
10/21/2025
Special inspection requirement — Duct leakage testing, insulation and design
10/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/21/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
10/21/2025
Special inspection requirement — Energy Code Compliance Inspections
10/21/2025
Special inspection requirement — HVAC-R and service water heating equipment
10/21/2025
Special inspection requirement — Maintenance information
10/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
10/21/2025
Special inspection requirement — HVAC-R and service water heating system controls
10/21/2025
Special inspection requirement — Sprinkler Systems
10/21/2025
Special inspection requirement — Standpipe Systems
10/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/21/2025
Special inspection requirement — Post-installed Anchors
10/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/21/2025
Special inspection requirement — Heating Systems
10/21/2025
Special inspection requirement — Mechanical Systems
10/17/2025
Filed — New Building
MECHANICAL SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER X01297399-I1.
X01297399-I1
10/16/2025
Special inspection requirement — Masonry
10/16/2025
Special inspection requirement — Concrete - Cast-In-Place
10/16/2025
Special inspection requirement — Post-installed Anchors
10/16/2025
Special inspection requirement — Structural Cold-Formed Steel
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedEXPRESS BUILDERS JB, INC09/16/2026
DOB NOWSupport of ExcavationPermit IssuedEXPRESS BUILDERS JB, INC09/10/2026
1 project · most recent 03/18/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/18/2026Permit IssuedEXPRESS BUILDERS JB, INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric MXZ-SM36NAM2 36,000 BTU · Fan Coil Indoor ×1
PEFY-P36NMAU 36,000 BTU · Vrf Indoor ×1
PKA-A12LA 12,000 BTU · Fan Coil Indoor ×1
PUZ-A12NKA7 12,000 BTU · Condensing Unit ×1
Heating
Mitsubishi Electric PEFY-P36NMAU 40,000 BTU · Vrf Indoor ×1
PKA-A12LA 14,000 BTU · Fan Coil Indoor ×1
PUZ-A12NKA7 14,000 BTU · Condensing Unit ×1
Ventilation
Greenheck CUE-080-VG 200 BTU · Exhaust Fan ×6
G-080-VG 250 CFM · Exhaust Fan ×5
CUE-100-VG 900 CFM · Exhaust Fan ×1
G-100-VG 900 CFM · Exhaust Fan ×1
1 project · most recent 03/18/2026
Sprinkler System
FiledStatusContractorScope
03/18/2026——Sprinkler System
1 project · most recent 03/18/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
03/18/2026——Gas, Storm, Water/Sanitary
5 projects · most recent 06/25/2026
General Wiring
FiledStatusContractorScope
06/25/2026Permit IssuedM.R. ELEC'L SERVICE LLCGeneral Wiring
12/20/2025Permit IssuedFIRST QUALITY ELECL LLC—
12/20/2025Permit IssuedFIRST QUALITY ELECL LLCGeneral Wiring
11/06/2025Permit IssuedGREEN STAR ELECTL CONT INGeneral Wiring
11/06/2025Permit IssuedGREEN STAR ELECTL CONT IN—
1 project · most recent 03/18/2026
Concrete
FiledStatusContractorScope
03/18/2026Permit IssuedEXPRESS BUILDERS JB, INCConcrete
▾Special Inspection Requirements (DOB NOW) — 36
DateRequirementInspectorRole
03/18/2026Excavations - Sheeting, Shoring, and BracingPaul Raymondspecial
03/18/2026Structural Stability – Alterations of existing buildingsPaul Raymondspecial
12/18/2025Standpipe Systems—special
10/21/2025Energy Code Compliance Inspections—progress
10/21/2025Final—progress
10/21/2025HVAC-R and service water heating equipment—energy_progress
10/21/2025Maintenance information—energy_progress
10/21/2025Electrical motors and elevators—energy_progress
10/21/2025Shutoff dampers—energy_progress
10/21/2025HVAC-R and service water piping design and insulation—energy_progress
10/21/2025HVAC-R and service water heating system controls—energy_progress
10/21/2025Duct leakage testing, insulation and design—energy_progress
10/21/2025Fire-Resistant Penetrations and Joints—special
10/21/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
10/21/2025Energy Code Compliance Inspections—progress
10/21/2025HVAC-R and service water heating equipment—energy_progress
10/21/2025Maintenance information—energy_progress
10/21/2025HVAC-R and service water piping design and insulation—energy_progress
10/21/2025HVAC-R and service water heating system controls—energy_progress
10/21/2025Sprinkler Systems—special
10/21/2025Standpipe Systems—special
10/21/2025Fire-Resistant Penetrations and Joints—special
10/21/2025Post-installed Anchors—special
10/21/2025Fire-Resistant Penetrations and Joints—special
10/21/2025Heating Systems—special
Latest 25 of 36.
▾Documents — 35 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/17/2026X01297399-S8Request digital key ↗
08/17/2026X01297399-I1Request digital key ↗
08/17/2026X01297399-S7Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits1
▸BISBPP-5 - Authorization to the Department of Transportation1
11/18/2025240364547Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
11/18/2025240364547Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/17/2026X01297399-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026X01297399-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/17/2026X01297399-I1Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/17/2026X01297399-S7Open ↗
08/17/2026X01297399-I1Open ↗
08/17/2026X01297399-S6Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/18/2025240364547Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
11/18/2025240364547Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026X01297399-S8Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/17/2026X01297399-I1Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
11/18/2025240364547Open ↗
▸DOB NOWStreet Tree Checklist1
08/17/2026X01297399-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/17/2026X01297399-S1Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
11/18/2025240364547Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
11/18/2025240364547Open ↗
▸Other Documents5
▸BISBPP - SUPPORTING DOCUMENTATION2
11/18/2025240364547Open ↗
11/18/2025240364547Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/17/2026X01297399-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/17/2026X01297399-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/17/2026X01297399-I1Open ↗