← Back
Primarily 4 family with 1 store or office
572 HENRY STREET
BROOKLYN · BIN 3004901
💬 Discuss this project
1900Year Built
5Stories
S4Building Class
R6BZoning
5,100 sfGross Floor Area
5Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Primarily 4 family with 1 store or office · Owner of record: 572 HENRY STREET LLC · 1,750 sf lot · 2.91 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 32p · 1 filing · 3 docs
Floor 2
Floor 1
Basement1p · 2 filings · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
M JUST ARCHITECTURE709/13/2026
572 HENRY STREET LLC703/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M JUST ARCHITECTURE PC307/30/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JUST ARCHITECTURE303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEGLIACCIO.IMPROVEMENTSGeneral Contractor408/16/2026
BIG APPLE SEWER & DRAIN IPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AG ENGINEERING PLLC8899107/30/2026
CONSULTING ENGINEER5093112/21/2023
ASE ENGINEERING PLLC5785103/10/2020
Building Lifecycle
All (53)Filed (3)Permit Issued (3)Signed Off (2)Violation (22)Objection (14)Special Inspection (9)
08/14/2026
Permit issued — Mechanical Systems
B01432645-I1-MS
07/30/2026
Filed — Alteration
MECHANICAL WORK ONLY TO REMOVE EXISTING FRIEDRICH UNIT AND TO INSTALL NEW ELECTRIC SPLIT AC SYSTEMAT EXISTING BASEMENT & CONDENSER AT LOW ROOF.
B01432645-I1
05/04/2026
Violation issued (HPD, closed)
A
11/20/2025
Violation issued (HPD, closed)
I
06/09/2025
Violation issued (HPD, closed)
A
03/28/2024
Signed off — Alteration
MECHANICAL WORK ONLY TO INSTALL NEW ELECTRIC SPLIT AC SYSTEM AT EXISTING BASEMENT & CONDENSER AT LOW ROOF.
B00917728-I1
02/23/2024
Permit issued — Mechanical Systems
B00917728-I1-MS
01/15/2024
Objection resolved — Addressed
01/15/2024
Objection resolved — Addressed
01/15/2024
Objection resolved — Addressed
01/15/2024
Objection resolved — Addressed
01/15/2024
Objection resolved — Addressed
01/15/2024
Objection resolved — Addressed
01/15/2024
Objection resolved — Addressed
12/28/2023
Objection raised — Other
12/28/2023
Objection raised — Other
12/28/2023
Objection raised — Scope
12/28/2023
Objection raised — Other
12/28/2023
Objection raised — Admin
12/28/2023
Objection raised — Fire_Protection
12/28/2023
Objection raised — Fire_Protection
12/21/2023
Filed — Alteration
MECHANICAL WORK ONLY TO INSTALL NEW ELECTRIC SPLIT AC SYSTEM AT EXISTING BASEMENT & CONDENSER AT LOW ROOF.
B00917728-I1
12/21/2023
Special inspection requirement — Maintenance information
John Natoli
12/21/2023
Special inspection requirement — HVAC-R and service water heating system controls
John Natoli
12/21/2023
Special inspection requirement — Tenant Protection Plan Compliance
John Natoli
12/21/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Natoli
12/21/2023
Special inspection requirement — Energy Code Compliance Inspections
John Natoli
12/21/2023
Special inspection requirement — HVAC-R and service water heating equipment
John Natoli
12/21/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
John Natoli
08/10/2023
Special inspection requirement — Mechanical Systems
John Natoli
08/10/2023
Special inspection requirement — Final
John Natoli
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/23/2023
Violation issued (HPD, closed)
A
01/13/2023
Violation issued (HPD, closed)
C
02/25/2022
Violation issued (HPD, closed)
A
02/05/2021
Signed off — Alteration
B00327054-I1
08/14/2020
Permit issued — Plumbing
B00327054-I1-PL
03/10/2020
Filed — Alteration
B00327054-I1
10/30/2019
Violation issued (HPD, closed)
I
10/22/2019
Violation issued (HPD, closed)
B
10/18/2018
Violation issued (HPD, closed)
I
11/27/2017
Violation issued (HPD, closed)
A
11/27/2017
Violation issued (HPD, closed)
B
11/27/2017
Violation issued (HPD, closed)
B
11/27/2017
Violation issued (HPD, closed)
B
11/27/2017
Violation issued (HPD, closed)
B
10/09/2015
Violation issued (HPD, closed)
I
05/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/09/2010
Violation issued (HPD, closed)
C
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/23/1996
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offNEGLIACCIO.IMPROVEMENTS08/14/2026
DOB NOWMechanical SystemsSigned-offNEGLIACCIO.IMPROVEMENTS02/23/2024
DOB NOWPlumbingSigned-offBIG APPLE SEWER & DRAIN I08/14/2020
BISOTISSUEDCAPEZZANO CONSTRUCTION08/18/2020
BISMHISSUEDSUPERIOR COOLING CORP07/18/2011
BISMHISSUEDSUPERIOR COOLING CORP12/22/2009
BISPLISSUEDJ.E.S. PLBG & HTG CORP01/30/1998
BISPLISSUEDJ.E.S. PLBG & HTG CORP01/07/1998
BISBLISSUEDJ.E.S. PLBG & HTG CORP01/07/1998
BIS—ISSUEDCITY KING DECORATION INC08/22/1997
BISOTISSUEDTEAM STRUCTURE CO. INC.06/21/1996
1 project · most recent 07/30/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/30/2026Signed-offNEGLIACCIO.IMPROVEMENTSHeating and Air Conditioning Systems
Heat / Cool
Gree GS24HP230V1ASI 24,000 BTU · Heat Pump Outdoor ×2
1 project · most recent 08/14/2020
General Wiring
FiledStatusContractorScope
08/14/2020CompletePETER J. CATANZARO, INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
12/21/2023Maintenance informationJohn Natolienergy_progress
12/21/2023HVAC-R and service water heating system controlsJohn Natolienergy_progress
12/21/2023Tenant Protection Plan ComplianceJohn Natolispecial
12/21/2023Fire-Resistant Penetrations and JointsJohn Natolispecial
12/21/2023Energy Code Compliance InspectionsJohn Natoliprogress
12/21/2023HVAC-R and service water heating equipmentJohn Natolienergy_progress
12/21/2023HVAC-R and service water piping design and insulationJohn Natolienergy_progress
08/10/2023Mechanical SystemsJohn Natolispecial
08/10/2023FinalJohn Natoliprogress
▾Documents — 61 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch2
08/16/2026B01432645-I1Request digital key ↗
08/14/2026B00917728-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
09/02/2026B00327054-I1Request digital key ↗
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION5
05/27/2020322043445Open ↗
05/20/2020322043445Open ↗
03/09/2020322043445Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION3
08/18/2020322043445Open ↗
07/22/2011320328622Open ↗
12/23/2009320104187Open ↗
▸Seals & Professional Certifications12
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
03/09/2020322043445Open ↗
11/30/2011320328622Open ↗
07/22/2011320328622Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/16/2026B01432645-I1Open ↗
08/13/2026B00917728-I1Open ↗
08/13/2026B00327054-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026B00917728-I1Open ↗
08/26/2026B00917728-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026B00917728-I1Open ↗
▸Trade Schedules & Equipment4
▸BISEQUIPMENT USE APPLICATION/PERMIT3
11/30/2011320328622Open ↗
06/30/2011320328622Open ↗
12/03/2009320104187Open ↗
▸BISEQUIPMENT USE PERMITS1
11/30/2011320328622Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
05/21/2020322043445Open ↗
▸Environmental & Asbestos7
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
06/30/2011320328622Open ↗
12/03/2009320104187Open ↗
12/03/2009320104187Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/16/2026B01432645-I1Open ↗
08/13/2026B00917728-I1Open ↗
08/13/2026B00327054-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/21/2020322043445Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY3
11/30/2011320328622Open ↗
07/22/2011320328622Open ↗
06/30/2011320328622Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
03/15/2021322043445Open ↗
03/15/2021322043445Open ↗
08/14/2020322043445Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
03/15/2021322043445Open ↗
11/30/2011320328622Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
03/09/2020322043445Open ↗
▸Inspections & Test Reports6
▸BISTECHNICAL REPORT: RESPONSIBILITY5
03/15/2021322043445Open ↗
03/15/2021322043445Open ↗
03/15/2021322043445Open ↗
Showing 3 of 5 on file for this type
▸BISSTRUCTURAL STABILITY - EXISTING BUILDINGS1
08/18/2020322043445Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
03/15/2021322043445Open ↗
11/30/2011320328622Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
06/30/2011320328622Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
03/15/2021322043445Open ↗
05/21/2020322043445Open ↗
03/09/2020322043445Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
12/03/2009320104187Open ↗
▸BISEFILING COVER SHEET1
03/09/2020322043445Open ↗