← Back
Walk-up cooperative
574 44 STREET
BROOKLYN · BIN 3011270
💬 Discuss this project
1914Year Built
4Stories
C6Building Class
R6AZoning
13,776 sfGross Floor Area
16Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Walk-up cooperative · Owner of record: PLEASANT VIEW ASSOCIATIONS INC · 4,991 sf lot · 2.76 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
RoofUnder Construction9p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EXO INDUSTRIES609/26/2026
PLEASANT VIEW ASSOCIATIONS INC608/29/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MCHENERY TESTING LAB404/22/2026
MVN ARCHITECT LLC204/02/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SOMMA DESIGN CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EXO INDUSTRIES CORPGeneral Contractor709/26/2026
BLAZE ELECTRIC INC.Electrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SONI ENGINEERING CONSULTI9819205/26/2026
MUNICIPAL TESTING LABORAT230204/02/2026
Building Lifecycle
All (46)Filed (8)Permit Issued (8)Violation (8)Inspection (6)Objection (2)Special Inspection (14)
09/25/2026
Permit issued — Sidewalk Shed
B01373335-I1-SH
08/26/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/26/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/30/2026
Permit issued — Sidewalk Shed
B01373335-I1-SH
06/10/2026
Special inspection requirement — Post-installed Anchors
nayan soni
06/10/2026
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
nayan soni
06/08/2026
Objection raised — Other
06/08/2026
Objection resolved — Addressed
05/26/2026
Filed — Alteration
Installation of suspended scaffold for facade work and/or inspection. Amend #1 change tieback to anchor to wall
B01377128-P1
05/14/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/07/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/05/2026
Permit issued — General Construction
B01329572-I1-GC
05/01/2026
Special inspection requirement — Masonry
CLOUD LEE
05/01/2026
Special inspection requirement — Tenant Protection Plan Compliance
CLOUD LEE
05/01/2026
Special inspection requirement — Post-installed Anchors
CLOUD LEE
05/01/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
CLOUD LEE
05/01/2026
Special inspection requirement — Preliminary
Michael Notaro
05/01/2026
Special inspection requirement — Final
Michael Notaro
04/27/2026
Permit issued — Suspended Scaffold
B01377128-I1-SC
04/23/2026
Permit issued — Protection and Mechanical Methods
B01378065-I1-PMM
04/22/2026
Filed — Alteration
PROPOSED INSTALLATION OF MATERIAL HOIST AS PER PLANS. HOIST SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B01378065-I1
04/13/2026
Filed — Alteration
Installation of suspended scaffold for facade work and/or inspection. Amend #1 change tieback to anchor to wall
B01377128-I1
04/06/2026
Filed — Alteration
PROPOSED INSTALLATION OF DEBRIS CHUTE AS PER PLANS. CHUTE SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B01376781-I1
04/06/2026
Permit issued — Protection and Mechanical Methods
B01376781-I1-PMM
04/03/2026
Permit issued — Sidewalk Shed
B01373335-I1-SH
04/03/2026
Permit issued — Supported Scaffold
B01373343-I1-SF
04/02/2026
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B01373335-I1
04/02/2026
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B01373343-I1
04/02/2026
Filed — Alteration
SCOPE OF WORK LIMITED TO PARAPET REPL., MISC. BRICK REPAIR & POINTING, STONE REPAIR, REPAIR & REPLACEMENTS OF LINTELS & SILLS, PER RULE 1-RCNY 101-14
B01329572-P1
04/01/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
CLOUD LEE
04/01/2026
Special inspection requirement — Tenant Protection Plan Compliance
CLOUD LEE
04/01/2026
Special inspection requirement — Final
Michael Notaro
04/01/2026
Special inspection requirement — Preliminary
Michael Notaro
04/01/2026
Special inspection requirement — Post-installed Anchors
CLOUD LEE
04/01/2026
Special inspection requirement — Masonry
CLOUD LEE
12/08/2025
Filed — Alteration
SCOPE OF WORK LIMITED TO PARAPET REPL., MISC. BRICK REPAIR & POINTING, STONE REPAIR, REPAIR & REPLACEMENTS OF LINTELS & SILLS, PER RULE 1-RCNY 101-14
B01329572-I1
11/21/2023
Violation issued (HPD, closed)
I
11/10/2022
Violation issued (HPD, closed)
I
02/22/2022
Violation issued (HPD, closed)
A
11/02/2016
Violation issued (HPD, closed)
I
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedEXO INDUSTRIES CORP09/25/2026
DOB NOWSidewalk ShedPermit IssuedEXO INDUSTRIES CORP06/30/2026
DOB NOWGeneral ConstructionPermit IssuedEXO INDUSTRIES CORP05/05/2026
DOB NOWSuspended ScaffoldPermit IssuedEXO INDUSTRIES CORP04/27/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedEXO INDUSTRIES CORP04/23/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedEXO INDUSTRIES CORP04/06/2026
DOB NOWSidewalk ShedPermit IssuedEXO INDUSTRIES CORP04/03/2026
DOB NOWSupported ScaffoldPermit IssuedEXO INDUSTRIES CORP04/03/2026
BISBLISSUEDZONE PLUMBING & HEATING C09/27/2016
BISPLISSUEDZONE PLUMBING & HEATING C09/09/2016
3 projects · most recent 04/06/2026
General Wiring
FiledStatusContractorScope
04/06/2026CompleteRIVIERA ELECT BROS CORP—
03/17/2026Permit IssuedRICHARD NEU—
11/01/2021CompleteBLAZE ELECTRIC INC.General Wiring
2 projects · most recent 04/02/2026
Scaffold Sidewalk Shed
FiledStatusContractorScope
04/02/2026Permit IssuedEXO INDUSTRIES CORPScaffold
04/02/2026Permit IssuedEXO INDUSTRIES CORPSidewalk Shed
1 project · most recent 05/26/2026
Suspended Scaffold (SC)
FiledStatusContractorScope
05/26/2026Permit IssuedEXO INDUSTRIES CORPSuspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
08/26/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/26/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/14/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/07/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/07/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/07/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
06/10/2026Post-installed Anchorsnayan sonispecial
06/10/2026Alternative Materials - OTCR Buildings Bulletin Numbernayan sonispecial
05/01/2026MasonryCLOUD LEEspecial
05/01/2026Tenant Protection Plan ComplianceCLOUD LEEspecial
05/01/2026Post-installed AnchorsCLOUD LEEspecial
05/01/2026Structural Stability – Alterations of existing buildingsCLOUD LEEspecial
05/01/2026PreliminaryMichael Notaroprogress
05/01/2026FinalMichael Notaroprogress
04/01/2026Structural Stability – Alterations of existing buildingsCLOUD LEEspecial
04/01/2026Tenant Protection Plan ComplianceCLOUD LEEspecial
04/01/2026FinalMichael Notaroprogress
04/01/2026PreliminaryMichael Notaroprogress
04/01/2026Post-installed AnchorsCLOUD LEEspecial
04/01/2026MasonryCLOUD LEEspecial
▾Documents — 54 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/19/2026B01329572-P1Request digital key ↗
08/19/2026B01329572-I1Request digital key ↗
08/17/2026B01373343-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits6
▸BISWORK PERMIT APPLICATION2
09/08/2016340419960Open ↗
09/08/2016340419960Open ↗
▸DOB NOWLPC Approval/Permit2
08/13/2026B01329572-P1Open ↗
08/13/2026B01329572-I1Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
09/08/2016340419960Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
04/05/2017340419960Open ↗
▸Seals & Professional Certifications15
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/19/2026B01329572-P1Open ↗
08/19/2026B01329572-I1Open ↗
08/17/2026B01373343-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/28/2026B01329572-I1Open ↗
08/23/2026B01377128-I1Open ↗
08/23/2026B01377128-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026B01329572-I1Open ↗
08/22/2026B01329572-P1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
09/08/2016340419960Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/08/2016340419960Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/08/2016340419960Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
06/22/2017340419960Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING1
09/08/2016340419960Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
09/08/2016340419960Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
09/08/2016340419960Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/08/2016340419960Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/19/2026B01329572-I1Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
09/08/2016340419960Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/22/2017340419960Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/08/2016340419960Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
06/22/2017340419960Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/08/2016340419960Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
07/25/2017340419960Open ↗
06/22/2017340419960Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
06/22/2017340419960Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
06/22/2017340419960Open ↗
09/08/2016340419960Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
04/25/2017340419960Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
09/08/2016340419960Open ↗
▸Other Documents8
▸DOB NOWManufacturer's Specifications3
08/16/2026B01377128-I1Open ↗
08/15/2026B01377128-P1Open ↗
08/13/2026B01377128-I1Open ↗
▸DOB NOWCalculations3
08/16/2026B01377128-I1Open ↗
08/15/2026B01377128-P1Open ↗
08/13/2026B01377128-I1Open ↗
▸DOB NOWProof of Historic Building2
08/13/2026B01329572-P1Open ↗
08/13/2026B01329572-I1Open ↗