← Back
Three families
578 EAST 166 STREET
BRONX · Morrisania · BIN 2114984
💬 Discuss this project
2007Year Built
3Stories
C0Building Class
R6Zoning
3,804 sfGross Floor Area
3Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Three families · Owner of record: 578 EAST 166 LLC · 2,743 sf lot · 1.39 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Roof74p · 1 filing · 20 docs
Floor 374p · 1 filing · 20 docs
Floor 272p · 1 filing · 20 docs
Floor 173p · 1 filing · 20 docs
Site & exterior20p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SEDGEWICK DEVELOPMENT1103/21/2026
578 EAST 166 LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/15/2023$880K—Private party → Private party$231/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEANDRO NILS DICKSON ARCHITECT, LLC501/28/2026
ALL CITY ENGINEERING, P.C.906/25/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPEDITING 4 U1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
B&B MECH PLBG & HTG LLCPlumbing507/08/2026
AB CONTRACTING USA INCGeneral Contractor404/09/2026
S R ELECTRICAL MECHANIC 005147General Contractor203/22/2026
YOSEF BLAUElectrical203/21/2026
TARGET PIPING NY LLCFire Protection107/08/2026
LEANDRO N DICKSONElectrical103/21/2026
TARGET PIPING NYGeneral Contractor103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION15191201/28/2026
Building Lifecycle
All (165)Filed (14)Permit Issued (6)Signed Off (6)Violation (60)Inspection (10)Objection (39)Special Inspection (30)
07/14/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-I1
03/10/2026
Objection raised — Admin
03/05/2026
Objection resolved — Addressed
02/18/2026
Objection raised — Admin
02/18/2026
Objection resolved — Addressed
02/13/2026
Objection raised — Admin
01/28/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-P8
01/20/2026
Special inspection requirement — Maintenance information
Younes Abouyaala
01/20/2026
Special inspection requirement — Permanent certificate
Younes Abouyaala
01/20/2026
Special inspection requirement — Metering
Younes Abouyaala
01/20/2026
Special inspection requirement — Air barrier — testing
Younes Abouyaala
01/20/2026
Special inspection requirement — Fenestration areas
Younes Abouyaala
01/20/2026
Special inspection requirement — Interior lighting power
Younes Abouyaala
01/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
Younes Abouyaala
01/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
01/20/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Younes Abouyaala
01/20/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Younes Abouyaala
01/20/2026
Special inspection requirement — Insulation placement and R values
Younes Abouyaala
01/20/2026
Special inspection requirement — Fenestration air leakage
Younes Abouyaala
01/20/2026
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
01/20/2026
Special inspection requirement — Air barrier - visual inspection
Younes Abouyaala
11/17/2025
Violation issued (HPD, closed)
I
08/05/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-S3
07/31/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-S4
07/23/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-S5
07/23/2025
Signed off — Alteration
X01057852-I1
07/17/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
07/17/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/16/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-P7
06/25/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-P6
06/25/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/24/2025
Special inspection requirement — HVAC-R and service water heating equipment
Younes Abouyaala
06/24/2025
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
06/24/2025
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
06/24/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Younes Abouyaala
06/24/2025
Special inspection requirement — Maintenance information
Younes Abouyaala
06/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
06/20/2025
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
06/13/2025
Violation issued (HPD, closed)
A
06/11/2025
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
06/11/2025
Inspection — Pass-Final SP - Up to 9 Requested Floors
Pass
View inspection ↗
06/10/2025
Special inspection requirement — HVAC-R and service water heating equipment
Younes Abouyaala
06/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
06/10/2025
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
06/10/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Younes Abouyaala
06/10/2025
Special inspection requirement — Heating Systems
Younes Abouyaala
06/10/2025
Special inspection requirement — Maintenance information
Younes Abouyaala
06/05/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-P5
06/05/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-S2
06/04/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
06/04/2025
Special inspection requirement — Sprinkler Systems
Younes Abouyaala
05/29/2025
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
05/29/2025
Special inspection requirement — HVAC-R and service water heating equipment
Younes Abouyaala
05/22/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-P4
05/22/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-P3
05/13/2025
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
04/28/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00749392-P2
04/04/2025
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
03/27/2025
Permit issued — General Construction
X00749392-I1-GC
Latest 60 of 165 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedAB CONTRACTING USA03/27/2025
DOB NOWMechanical SystemsSigned-offAB CONTRACTING USA03/26/2025
DOB NOWPlumbingSigned-offTARGET PIPING NY LLC03/26/2025
DOB NOWSprinklersSigned-offTARGET PIPING NY LLC03/26/2025
DOB NOWBoiler EquipmentSigned-offTARGET PIPING NY LLC03/26/2025
DOB NOWConstruction FenceSigned-offAB CONTRACTING USA03/10/2025
BISEQISSUEDS&E BEST CONSTRUCTION CORP03/30/2007
BIS—ISSUEDS&E BEST CONSTRUCTION CORP03/30/2007
BISPLISSUEDS.T.P PLUMBING & HEATING INC03/28/2007
BISEQISSUEDS&E BEST CONSTRUCTION CORP02/09/2007
BIS—ISSUEDS&E BEST CONSTRUCTION CORP02/09/2007
BIS—ISSUEDALWAYS FAST, INC.11/28/2006
BISEQISSUEDALWAYS FAST, INC.11/28/2006
1 project · most recent 01/28/2026
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/28/2026Permit IssuedAB CONTRACTING USA INCVentilation Systems
Ventilation
Greenheck SP-A110 100 CFM · Exhaust Fan ×2
CSP-B110 100 CFM · Exhaust Fan ×1
1 project · most recent 01/28/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
01/28/2026Signed-offTARGET PIPING NY LLCGas, Storm, Water/Sanitary
2 projects · most recent 06/10/2025
General Wiring
FiledStatusContractorScope
06/10/2025CompleteS&R ELECTRICAL & MECHANIC—
03/25/2025CompleteS&R ELECTRICAL & MECHANICGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
07/17/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
07/17/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/25/2025Pass-Final CND-Occupancy InspectionPassView ↗
06/20/2025Pass-Final Boiler Equipment InspectionPassView ↗
06/11/2025Pass-Final PL - Up to 9 Requested FloorsPassView ↗
06/11/2025Pass-Final SP - Up to 9 Requested FloorsPassView ↗
06/04/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/13/2025Pass-Final PL - Up to 9 Requested FloorsPassView ↗
04/04/2025Pass-Final PL - Up to 9 Requested FloorsPassView ↗
09/07/2023Pass-Final SP - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 72
DateRequirementInspectorRole
01/20/2026Maintenance informationYounes Abouyaalaenergy_progress
01/20/2026Fenestration air leakageYounes Abouyaalaenergy_progress
01/20/2026Air barrier — testing Younes Abouyaalaenergy_progress
01/20/2026Permanent certificateYounes Abouyaalaenergy_progress
01/20/2026Interior lighting powerYounes Abouyaalaenergy_progress
01/20/2026Air barrier - visual inspectionYounes Abouyaalaenergy_progress
01/20/2026Fenestration areasYounes Abouyaalaenergy_progress
01/20/2026MeteringYounes Abouyaalaenergy_progress
01/20/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
01/20/2026Structural Stability – Alterations of existing buildingsYounes Abouyaalaspecial
01/20/2026Energy Code Compliance InspectionsYounes Abouyaalaprogress
01/20/2026Fire-Resistance Rated ConstructionYounes Abouyaalaprogress
01/20/2026Fenestration and door U-factor and product ratingsYounes Abouyaalaenergy_progress
01/20/2026Insulation placement and R valuesYounes Abouyaalaenergy_progress
06/24/2025HVAC-R and service water heating system controlsYounes Abouyaalaenergy_progress
06/24/2025HVAC-R and service water heating equipmentYounes Abouyaalaenergy_progress
06/24/2025Maintenance informationYounes Abouyaalaenergy_progress
06/24/2025HVAC-R and service water piping design and insulationYounes Abouyaalaenergy_progress
06/24/2025Energy Code Compliance InspectionsYounes Abouyaalaprogress
06/24/2025Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
06/10/2025Heating SystemsYounes Abouyaalaspecial
06/10/2025HVAC-R and service water heating system controlsYounes Abouyaalaenergy_progress
06/10/2025Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
06/10/2025HVAC-R and service water heating equipmentYounes Abouyaalaenergy_progress
06/10/2025Maintenance informationYounes Abouyaalaenergy_progress
Latest 25 of 72.
▾Documents — 92 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch14
08/20/2026X01057852-I1Request digital key ↗
08/19/2026X00749392-P1Request digital key ↗
08/19/2026X00749392-S3Request digital key ↗
Showing 3 of 14 on file for this type
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION4
05/29/2025240298343Open ↗
05/28/2025240298343Open ↗
05/27/2025240298343Open ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWRestrictive Declaration/Easement 12
08/15/2026X00749392-I1Open ↗
08/13/2026X00749392-P8Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00749392-I1Open ↗
▸Seals & Professional Certifications37
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/20/2026X01057852-I1Open ↗
08/19/2026X00749392-P1Open ↗
08/19/2026X00749392-S4Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
09/23/2026X00749392-S5Open ↗
08/31/2026X00749392-P8Open ↗
08/31/2026X00749392-P8Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/23/2026X00749392-S5Open ↗
08/31/2026X00749392-P8Open ↗
08/27/2026X00749392-P6Open ↗
Showing 3 of 8 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
04/22/2021240298343Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/22/2021240298343Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
02/09/2022240298343Open ↗
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-5: Asbestos Assessment Report13
08/19/2026X00749392-P1Open ↗
08/19/2026X00749392-S3Open ↗
08/19/2026X00749392-S2Open ↗
Showing 3 of 13 on file for this type
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
03/14/2022240298343Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
03/21/2022240298343Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
02/14/2022240298343Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
04/22/2021240298343Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026X00749392-I1Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
03/14/2022240298343Open ↗
03/08/2022240298343Open ↗
04/22/2021240298343Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
04/22/2021240298343Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
04/22/2021240298343Open ↗
▸BISBOROUGH INTAKE FORM1
03/24/2022240298343Open ↗
▸Other Documents9
▸DOB NOWSite Survey: Initial4
08/13/2026X00749392-I1Open ↗
08/13/2026X00749392-P1Open ↗
08/13/2026X00749392-P8Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/19/2026X00749392-P1Open ↗
08/19/2026X00749392-P7Open ↗
08/15/2026X00749392-P8Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/13/2026X00749392-I1Open ↗