← Back
Cape Cod
58-15 188 STREET
QUEENS · BIN 4128523
💬 Discuss this project
1945Year Built
1.67Stories
A0Building Class
R2AZoning
1,501 sfGross Floor Area
1Units
Cape Cod · 4,000 sf lot · 0.38 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/11/2017$790K—— → —$526/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SYNERGIC DESIGN ARCHITECTS107/29/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ACCORD POWER INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SYNERGIC DESIGN LLC8561107/29/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
09/09/2025
Signed off — Alteration
Installation of 6.16 kw solar energy system on roof. No change of occupancy, use or egress.
Q01262486-I1
08/04/2025
Permit issued — Solar
Q01262486-I1-SL
07/29/2025
Filed — Alteration
Installation of 6.16 kw solar energy system on roof. No change of occupancy, use or egress.
Q01262486-I1
07/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Malathi Ananthakrishnan
07/28/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Malathi Ananthakrishnan
07/28/2025
Special inspection requirement — Energy Code Compliance Inspections
Malathi Ananthakrishnan
07/28/2025
Special inspection requirement — Final
Malathi Ananthakrishnan
07/28/2025
Special inspection requirement — Air barrier - visual inspection
Malathi Ananthakrishnan
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offACCORD POWER INC08/04/2025
BISPLISSUEDTOP PLUMBING GROUP,INC06/14/2017
BISOTISSUEDT&S HOME IMPROVEMENT INC02/17/2017
BISPLISSUEDBARMOR REHAB INC02/17/2017
2 projects · most recent 09/02/2025
HVAC Wiring
FiledStatusContractorScope
09/02/2025CompleteALL AROUND ELECTRIC CORP.HVAC Wiring
08/04/2025CompleteACCORD POWER ELECTRIC LLC—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/28/2025Fire-Resistant Penetrations and JointsMalathi Ananthakrishnanspecial
07/28/2025Structural Stability – Alterations of existing buildingsMalathi Ananthakrishnanspecial
07/28/2025Energy Code Compliance InspectionsMalathi Ananthakrishnanprogress
07/28/2025FinalMalathi Ananthakrishnanprogress
07/28/2025Air barrier - visual inspectionMalathi Ananthakrishnanenergy_progress
▾Documents — 40 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026Q01262486-I1Request digital key ↗
▸Applications & Permits8
▸BISWORK PERMIT APPLICATION4
06/21/2017440385129Open ↗
02/15/2017440385129Open ↗
02/15/2017440385129Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
08/09/2017440385129Open ↗
06/26/2017440385129Open ↗
02/15/2017440385129Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
10/26/2017440385129Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISRESTRICTION: RESTRICTIVE DECLARATION1
03/02/2017440385129Open ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026Q01262486-I1Open ↗
09/01/2026Q01262486-I1Open ↗
09/01/2026Q01262486-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01262486-I1Open ↗
09/01/2026Q01262486-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
02/15/2017440385129Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/15/2017440385129Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
10/22/2017440385129Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
02/15/2017440385129Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01262486-I1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
09/18/2017440385129Open ↗
06/26/2017440385129Open ↗
▸BISSCHEDULE B - PLUMBING1
02/15/2017440385129Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/15/2017440385129Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01262486-I1Open ↗
▸Energy Compliance4
▸BISAS-BUILT ENERGY ANALYSIS1
10/22/2017440385129Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
02/15/2017440385129Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
10/22/2017440385129Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
02/15/2017440385129Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
02/15/2017440385129Open ↗
▸Approvals, Objections & Sign-offs4
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
10/27/2017440385129Open ↗
10/26/2017440385129Open ↗
▸BISSUPERSEDING LETTER1
06/21/2017440385129Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01262486-I1Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
10/22/2017440385129Open ↗
02/15/2017440385129Open ↗
▸Filing & Intake Forms4
▸BISBOROUGH INTAKE FORM2
10/27/2017440385129Open ↗
10/26/2017440385129Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
02/15/2017440385129Open ↗
▸BISADDITIONAL INFORMATION1
07/05/2017440385129Open ↗