← Back
Cape Cod
58-19 210 STREET
QUEENS · Bayside · BIN 4160684
💬 Discuss this project
1955Year Built
1.67Stories
A0Building Class
R2AZoning
1,610 sfGross Floor Area
1Units
Cape Cod · 4,760 sf lot · 0.34 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/27/2021$925K—Private party → Private party$575/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMERILAND BROOK LLC401/05/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HONG KONG HOOD INCGeneral Contractor303/21/2026
TRI STATE PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AMERILAND BROOK LLC1506401/05/2022
Building Lifecycle
All (25)Filed (4)Permit Issued (2)Signed Off (2)Inspection (6)Special Inspection (11)
01/28/2022
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING ONE FAMILY HOUSE. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00534484-I1
01/21/2022
Signed off — Alteration
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#Q00534484
Q00534527-I1
01/21/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
01/10/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
01/06/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIAOHONG ZHAO
01/06/2022
Special inspection requirement — Energy Code Compliance Inspections
XIAOHONG ZHAO
01/06/2022
Special inspection requirement — Lighting controls
XIAOHONG ZHAO
01/05/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING ONE FAMILY HOUSE. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00534484-P1
10/22/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/20/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/20/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/20/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/05/2021
Filed — Alteration
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#Q00534484
Q00534527-P1
08/05/2021
Special inspection requirement — HVAC-R and service water heating system controls
XIAOHONG ZHAO
08/05/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
XIAOHONG ZHAO
08/05/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIAOHONG ZHAO
08/05/2021
Special inspection requirement — Energy Code Compliance Inspections
XIAOHONG ZHAO
08/05/2021
Special inspection requirement — Lighting controls
XIAOHONG ZHAO
08/05/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIAOHONG ZHAO
08/05/2021
Special inspection requirement — Energy Code Compliance Inspections
XIAOHONG ZHAO
08/05/2021
Special inspection requirement — HVAC-R and service water heating equipment
XIAOHONG ZHAO
06/16/2021
Permit issued — Plumbing
Q00534527-I1-PL
06/09/2021
Permit issued — General Construction
Q00534484-I1-GC
06/04/2021
Filed — Alteration
INTERIOR RENOVATION OF EXISTING ONE FAMILY HOUSE. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00534484-I1
06/04/2021
Filed — Alteration
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#Q00534484
Q00534527-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDW PLUMBING INC06/16/2021
DOB NOWGeneral ConstructionSigned-offHONG KONG HOOD INC06/09/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
01/21/2022Pass-Final General Construction Non-Directive 14PassView ↗
01/10/2022Fail-Final General Construction Non-Directive 14FailView ↗
10/22/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/20/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/20/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/20/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
01/06/2022Fire-Resistant Penetrations and JointsXIAOHONG ZHAOspecial
01/06/2022Energy Code Compliance InspectionsXIAOHONG ZHAOprogress
01/06/2022Lighting controlsXIAOHONG ZHAOenergy_progress
08/05/2021HVAC-R and service water heating system controlsXIAOHONG ZHAOenergy_progress
08/05/2021HVAC-R and service water piping design and insulationXIAOHONG ZHAOenergy_progress
08/05/2021Fire-Resistant Penetrations and JointsXIAOHONG ZHAOspecial
08/05/2021Energy Code Compliance InspectionsXIAOHONG ZHAOprogress
08/05/2021Lighting controlsXIAOHONG ZHAOenergy_progress
08/05/2021Fire-Resistant Penetrations and JointsXIAOHONG ZHAOspecial
08/05/2021Energy Code Compliance InspectionsXIAOHONG ZHAOprogress
08/05/2021HVAC-R and service water heating equipmentXIAOHONG ZHAOenergy_progress
▾Documents — 23 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026Q00534527-P1Request digital key ↗
08/27/2026Q00534527-I1Request digital key ↗
08/26/2026Q00534484-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications15
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026Q00534484-I1Open ↗
09/01/2026Q00534484-I1Open ↗
08/28/2026Q00534484-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026Q00534527-I1Open ↗
08/27/2026Q00534527-P1Open ↗
08/26/2026Q00534484-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026Q00534484-I1Open ↗
08/28/2026Q00534484-P1Open ↗
08/23/2026Q00534527-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/26/2026Q00534484-P1Open ↗
08/26/2026Q00534484-I1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026Q00534484-I1Open ↗
08/13/2026Q00534527-I1Open ↗