← Back
Predominantly retail with other uses
58-60 BROWN PLACE
QUEENS · BIN 4062244
💬 Discuss this project
2018Year Built
2Stories
K4Building Class
R4-1Zoning
10,854 sfGross Floor Area
3Units
0 Open Violations
Predominantly retail with other uses · Owner of record: AVALANCHE ENTERPRISES INC · 6,288 sf lot · 1.73 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Roof6p · 2 filings · 20 docs
Penthouse1p · 1 filing · 14 docs
Floor 23p · 2 filings · 20 docs
Floor 13p · 2 filings · 20 docs
Cellar4p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RISTIC BUILDERS403/22/2026
BUILDINGRITE703/22/2026
SATEMPA SERVICES AVE103/22/2026
LATEMPA SERVICES403/22/2026
AVALANCHE ENTERPRISES403/22/2026
OWNER OF 58-40 69 ST103/22/2026
JABLOWSKY ENTERPRISES103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RLM ENGINEERING PLLC611/06/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VINCENZO NAPOLITANOElectrical503/21/2026
NAPSTAR ELECTRIC INC 003445General Contractor503/22/2026
ETHOS PLUMBING CORPPlumbing407/08/2026
FLINT MECHANICAL CORPFire Protection307/08/2026
FRANK J QUATELAElectrical103/21/2026
PATH MECHANICAL CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RLM ENGINEERING PLLC6913611/06/2025
Building Lifecycle
All (66)Filed (6)Permit Issued (8)Signed Off (2)Violation (30)Inspection (2)Special Inspection (18)
12/04/2025
Signed off — Alteration
Filing for the installation of 7 new condensing units/heat pump units, 11 new air handlers, 10 ERV units, related piping and ductwork under this application. This application filing supersedes Mechanical worktype only in BIS #421545830.
Q00242665-I1
11/18/2025
Signed off — Alteration
Filing in conjunction with NB 421164304 for the installation of a new sprinkler service, domestic service, 2 backflow preventers, sprinkler heads,3 bathrooms, storm drains, sewer ejector pump with related piping as per plans filed herewith.
Q00276004-I1
11/07/2025
Special inspection requirement — HVAC insulation and sealing
Ronald Merhige
11/07/2025
Special inspection requirement — Energy Code Compliance Inspections
Ronald Merhige
11/07/2025
Special inspection requirement — Mechanical Systems
Ronald Merhige
11/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ronald Merhige
11/07/2025
Special inspection requirement — Final
Ronald Merhige
11/07/2025
Special inspection requirement — HVAC and service water heating system controls
Ronald Merhige
11/07/2025
Special inspection requirement — Maintenance information
Ronald Merhige
11/07/2025
Special inspection requirement — HVAC and service water heating equipment
Ronald Merhige
11/06/2025
Filed — Alteration
Filing for the installation of 7 new condensing units/heat pump units, 11 new air handlers, 10 ERV units, related piping and ductwork under this application. This application filing supersedes Mechanical worktype only in BIS #421545830.
Q00242665-P1
05/01/2025
Permit issued — Plumbing
Q00276004-I1-EW-SP
01/09/2025
Permit issued — Plumbing
Q00276004-I1-PL
03/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ronald Merhige
03/19/2024
Special inspection requirement — Sprinkler Systems
Ronald Merhige
03/19/2024
Special inspection requirement — Energy Code Compliance Inspections
Ronald Merhige
03/19/2024
Special inspection requirement — HVAC and service water heating equipment
Ronald Merhige
03/19/2024
Special inspection requirement — HVAC and service water heating system controls
Ronald Merhige
03/15/2024
Filed — Alteration
Filing in conjunction with NB 421164304 for the installation of a new sprinkler service, domestic service, 2 backflow preventers, sprinkler heads,3 bathrooms, storm drains, sewer ejector pump with related piping as per plans filed herewith.
Q00276004-P3
03/06/2024
Filed — Alteration
Filing in conjunction with NB 421164304 for the installation of a new sprinkler service, domestic service, 2 backflow preventers, sprinkler heads,3 bathrooms, storm drains, sewer ejector pump with related piping as per plans filed herewith.
Q00276004-P2
11/22/2023
Special inspection requirement — HVAC and service water heating equipment
Ronald Merhige
11/22/2023
Special inspection requirement — HVAC and service water heating system controls
Ronald Merhige
11/22/2023
Special inspection requirement — Energy Code Compliance Inspections
Ronald Merhige
11/22/2023
Special inspection requirement — Sprinkler Systems
Ronald Merhige
11/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ronald Merhige
10/27/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
10/25/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/10/2023
Permit issued — Plumbing
Q00276004-I1-PL
10/10/2023
Permit issued — Sprinklers
Q00276004-I1-EW-SP
10/21/2022
Permit issued — Sprinklers
Q00276004-I1-EW-SP
07/25/2022
Filed — Alteration
Filing in conjunction with NB 421164304 for the installation of a new sprinkler service, domestic service, 2 backflow preventers, sprinkler heads,3 bathrooms, storm drains, sewer ejector pump with related piping as per plans filed herewith.
Q00276004-P1
02/04/2022
Permit issued — Plumbing
Q00276004-I1-PL
11/24/2021
Permit issued — Mechanical Systems
Q00242665-I1-MS
10/06/2021
Violation issued (ECB, closed)
Construction
09/30/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/09/2020
Violation issued (ECB, closed)
Construction
07/09/2020
Violation issued (ECB, closed)
Construction
07/08/2020
Permit issued — Plumbing
Q00276004-I1-PL
06/11/2020
Violation issued (ECB, closed)
Construction
06/11/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/11/2020
Violation issued (ECB, closed)
Construction
06/11/2020
Violation issued (ECB, closed)
Construction
12/19/2019
Filed — Alteration
Filing in conjunction with NB 421164304 for the installation of a new sprinkler service, domestic service, 2 backflow preventers, sprinkler heads,3 bathrooms, storm drains, sewer ejector pump with related piping as per plans filed herewith.
Q00276004-I1
10/30/2019
Filed — Alteration
Filing for the installation of 7 new condensing units/heat pump units, 11 new air handlers, 10 ERV units, related piping and ductwork under this application. This application filing supersedes Mechanical worktype only in BIS #421545830.
Q00242665-I1
07/17/2019
Violation issued (ECB, closed)
Construction
12/12/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/12/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/12/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/13/2018
Violation issued (ECB, closed)
Construction
09/13/2018
Violation issued (ECB, closed)
Construction
09/13/2018
Violation issued (ECB, closed)
Construction
09/13/2018
Violation issued (ECB, closed)
Unknown
05/11/2018
Violation issued (ECB, closed)
Construction
02/22/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/05/2017
Violation issued (ECB, closed)
Construction
12/10/2016
Violation issued (ECB, closed)
Construction
12/10/2016
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
12/10/2016
Violation issued (ECB, closed)
Construction
12/03/2016
Violation issued (ECB, closed)
Construction
12/03/2016
Violation issued (ECB, closed)
Construction
Latest 60 of 66 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offBLETSAS P&H CORP05/01/2025
DOB NOWPlumbingSigned-offETHOS PLUMBING CORP01/09/2025
DOB NOWPlumbingSigned-offETHOS PLUMBING CORP10/10/2023
DOB NOWSprinklersSigned-offBLETSAS P&H CORP10/10/2023
DOB NOWSprinklersSigned-offBLETSAS P&H CORP10/21/2022
DOB NOWPlumbingSigned-offETHOS PLUMBING CORP02/04/2022
DOB NOWMechanical SystemsSigned-offPATH MECHANICAL CORP11/24/2021
DOB NOWPlumbingSigned-offETHOS PLUMBING CORP07/08/2020
BIS—ISSUEDALL DIMENSION HOME IMPROVEMENT10/29/2025
BIS—ISSUEDBUILDINGRITE LLC03/31/2022
BISPLISSUEDETHOS PLUMBING CORP01/06/2022
BIS—ISSUEDBUILDINGRITE LLC12/07/2021
BIS—ISSUEDBUILDINGRITE LLC09/02/2020
BISPLISSUEDETHOS PLUMBING CORP07/08/2020
BISEQISSUEDCRF CONSTRUCTION INC04/21/2020
BIS—ISSUEDBUILDINGRITE LLC09/26/2019
BISMHISSUEDCRF CONSTRUCTION INC09/26/2019
BISMHISSUEDCRF CONSTRUCTION INC11/14/2018
BISEQISSUEDCRF CONSTRUCTION INC11/14/2018
BIS—ISSUEDBUILDINGRITE LLC11/07/2018
BISPLISSUEDEP PLUMBING INC05/02/2018
BISMHISSUEDRISTIC BUILDERS LLC05/02/2018
BIS—ISSUEDRISTIC BUILDERS LLC03/27/2018
BIS—ISSUEDRISTIC BUILDERS LLC03/27/2018
BISEQISSUEDRISTIC BUILDERS LLC03/27/2018
BIS—ISSUEDRISTIC BUILDERS LLC03/14/2018
BIS—ISSUEDRISTIC BUILDERS LLC03/14/2018
BISEQISSUEDRISTIC BUILDERS LLC03/14/2018
BIS—ISSUEDLATEMPA SERVICES INC03/29/2017
BISEQISSUEDLATEMPA SERVICES INC01/05/2017
BIS—ISSUEDLATEMPA SERVICES INC03/30/2016
BISEQISSUEDSILVERCUP SCAFFOLDING 1 L01/12/2016
BISEQISSUEDLATEMPA SERVICES INC12/30/2015
BIS—ISSUEDLATEMPA SERVICES INC12/30/2015
BISEQISSUEDLATEMPA SERVICES INC12/16/2015
BIS—ISSUEDLATEMPA SERVICES INC12/16/2015
2 projects · most recent 02/06/2026
General Wiring HVAC Wiring
FiledStatusContractorScope
02/06/2026CompleteNAPSTAR ELECTRIC INCGeneral Wiring, HVAC Wiring
07/04/2018CompleteZEV ELECTRIC CORP.—
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
10/27/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/25/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
11/07/2025HVAC insulation and sealing Ronald Merhigeenergy_progress
11/07/2025Energy Code Compliance InspectionsRonald Merhigeprogress
11/07/2025Mechanical SystemsRonald Merhigespecial
11/07/2025Fire-Resistant Penetrations and JointsRonald Merhigespecial
11/07/2025FinalRonald Merhigeprogress
11/07/2025HVAC and service water heating system controls Ronald Merhigeenergy_progress
11/07/2025Maintenance informationRonald Merhigeenergy_progress
11/07/2025HVAC and service water heating equipment Ronald Merhigeenergy_progress
03/19/2024Fire-Resistant Penetrations and JointsRonald Merhigespecial
03/19/2024Sprinkler SystemsRonald Merhigespecial
03/19/2024Energy Code Compliance InspectionsRonald Merhigeprogress
03/19/2024HVAC and service water heating equipment Ronald Merhigeenergy_progress
03/19/2024HVAC and service water heating system controls Ronald Merhigeenergy_progress
11/22/2023HVAC and service water heating equipment Ronald Merhigeenergy_progress
11/22/2023HVAC and service water heating system controls Ronald Merhigeenergy_progress
11/22/2023Energy Code Compliance InspectionsRonald Merhigeprogress
11/22/2023Sprinkler SystemsRonald Merhigespecial
11/22/2023Fire-Resistant Penetrations and JointsRonald Merhigespecial
▾Documents — 209 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch - Plumbing4
08/26/2026Q00276004-P3Request digital key ↗
08/26/2026Q00276004-P2Request digital key ↗
08/26/2026Q00276004-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Sprinkler4
08/26/2026Q00276004-P3Request digital key ↗
08/26/2026Q00276004-P2Request digital key ↗
08/26/2026Q00276004-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems2
08/18/2026Q00242665-I1Request digital key ↗
08/18/2026Q00242665-P1Request digital key ↗
▸Applications & Permits48
▸BISWORK PERMIT APPLICATION25
01/14/2026421164304Open ↗
10/26/2020421164304Open ↗
08/10/2020421545830Open ↗
Showing 3 of 25 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION20
11/03/2025421545830Open ↗
10/20/2025421545821Open ↗
09/10/2025421164304Open ↗
Showing 3 of 20 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation2
09/24/2020421245021Open ↗
12/17/2015421245021Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
09/29/2022421164304Open ↗
▸Zoning, Tax Lot & Property Records5
▸BISZONING DIAGRAM2
01/18/2018421164304Open ↗
01/04/2016421164304Open ↗
▸BISTAX LOT: FINAL LOT NUMBER ISSUED1
01/04/2016421164304Open ↗
▸BISVERIFY TAX LOT1
10/17/2025421164304Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
10/17/2025421164304Open ↗
▸Seals & Professional Certifications43
▸DOB NOWProgress Inspector Seal & Signature12
09/27/2026Q00242665-I1Open ↗
09/27/2026Q00242665-I1Open ↗
09/27/2026Q00242665-I1Open ↗
Showing 3 of 12 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION11
05/17/2019421164304Open ↗
05/10/2018421545830Open ↗
12/19/2017421545830Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/26/2026Q00276004-P2Open ↗
08/26/2026Q00276004-P1Open ↗
08/26/2026Q00276004-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/27/2026Q00242665-I1Open ↗
09/27/2026Q00242665-I1Open ↗
08/29/2026Q00276004-I1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
01/06/2016440278735Open ↗
12/17/2015421245021Open ↗
12/09/2015440274365Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
01/06/2016440278735Open ↗
12/09/2015440274365Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
01/06/2016440278735Open ↗
12/09/2015440274365Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/17/2015421245021Open ↗
▸Trade Schedules & Equipment7
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
09/18/2017421545830Open ↗
07/21/2015421164304Open ↗
▸BISSEWER/HOUSE CON SIGNOFF: DEP HC 0211
08/29/2018421164304Open ↗
▸BISWATER CUT-OFF1
12/22/2015421188609Open ↗
▸BISGAS CUT-OFF1
12/22/2015421188609Open ↗
▸BISELECTRIC CUT-OFF1
12/22/2015421188609Open ↗
▸BISWATER METER PERMIT : DEP-METER1
12/22/2015421188609Open ↗
▸Safety & Tenant Protection7
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE2
12/31/2015421164304Open ↗
12/22/2015421188609Open ↗
▸BISSTREET TREE CHECKLIST1
12/12/2015421164304Open ↗
▸BISSTREET TREE SIGNOFF1
10/17/2025421164304Open ↗
▸BISSTREET TREES SITE PLAN1
10/17/2025421164304Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
12/22/2015421188609Open ↗
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
12/22/2015421188609Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/22/2015421188609Open ↗
▸BISRODENT CONTROL1
12/22/2015421188609Open ↗
▸Energy Compliance14
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS7
05/10/2018421545830Open ↗
01/08/2018421164304Open ↗
12/19/2017421545830Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY5
12/22/2025421164304Open ↗
12/19/2025421164304Open ↗
10/17/2025421164304Open ↗
Showing 3 of 5 on file for this type
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
01/06/2016440278735Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q00242665-I1Open ↗
▸Inspections & Test Reports17
▸BISTECHNICAL REPORT: RESPONSIBILITY8
12/22/2025421164304Open ↗
12/19/2025421164304Open ↗
10/17/2025421164304Open ↗
Showing 3 of 8 on file for this type
▸BISHYDRAULIC FLOW CALCULATIONS2
12/19/2017421545830Open ↗
12/19/2017421545830Open ↗
▸BISHYDRO FLOW TEST LETTER1
12/19/2017421545830Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER1
12/31/2015421164304Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
12/31/2015421164304Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
12/31/2015421164304Open ↗
▸BISDEMOLITION (DM) JOB SIGNOFF1
10/17/2025421164304Open ↗
▸BISTR2: CONCRETE FIELD TESTING TECHNICAL REPORT1
11/29/2023421164304Open ↗
▸BISSTRUCTURAL STEEL - DETAILS1
02/14/2024421164304Open ↗
▸Approvals, Objections & Sign-offs16
▸BISLETTERS - SUPPORTING DOCUMENTATION6
12/01/2018421545830Open ↗
11/28/2018421164304Open ↗
01/08/2018421164304Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE5
07/02/2025421164304Open ↗
06/21/2023421164304Open ↗
12/26/2017421164304Open ↗
Showing 3 of 5 on file for this type
▸BISSUPERSEDING LETTER2
08/10/2020421545830Open ↗
03/20/2018421164304Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/17/2025440278735Open ↗
▸BISTAP LETTER - DOM SVC : DEP-DOM1
12/22/2015421188609Open ↗
▸BISLANDMARKS APPROVAL1
12/22/2015421188609Open ↗
▸Cost, Insurance & Ownership13
▸BISPROJECT-SPECIFIC GL INSURANCE8
10/26/2020421164304Open ↗
09/27/2019421164304Open ↗
11/28/2018421164304Open ↗
Showing 3 of 8 on file for this type
▸BISAcord 25 (Acord Certificate of Liability Insurance)2
04/14/2016421164304Open ↗
04/14/2016421164304Open ↗
▸BISCOST AFFIDAVIT2
09/18/2017421545830Open ↗
12/09/2015440274365Open ↗
▸BISPROJECT SPECIFIC GENERAL LIABILITY INSURANCE1
04/14/2016421164304Open ↗
▸Filing & Intake Forms21
▸BISBOROUGH INTAKE FORM6
10/26/2020421164304Open ↗
08/10/2020421545830Open ↗
07/06/2020440274365Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING COVER SHEET6
09/18/2017421545821Open ↗
09/18/2017421545830Open ↗
12/17/2015421245021Open ↗
Showing 3 of 6 on file for this type
▸BISADDITIONAL INFORMATION6
09/24/2025421164304Open ↗
07/12/2023421164304Open ↗
07/12/2023421164304Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
01/06/2016440278735Open ↗
12/09/2015440274365Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
12/17/2015421245021Open ↗
▸Other Documents6
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION4
07/10/2025421164304Open ↗
12/15/2015421188609Open ↗
12/15/2015421188609Open ↗
Showing 3 of 4 on file for this type
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION2
10/26/2020421164304Open ↗
11/28/2018421164304Open ↗