| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 01/31/2024 | $2.1M | — | — → — | $688/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| BAYSIDE ENGINEERING PC | 16 | 07/29/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| LXC CONSTRUCTION INC | General Contractor | 16 | 07/08/2026 |
| RRP PLUMBING CORP | Fire Protection | 1 | 07/08/2026 |
| TRI STATE PLBG & HTG INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| SD TESTING & INSPECTION S | 7010 | 15 | 07/29/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Signed-off | RALPH W. LANDOLFI JR. | 02/28/2025 |
| DOB NOW | Mechanical Systems | Signed-off | LXC CONSTRUCTION INC | 11/25/2024 |
| DOB NOW | General Construction | Permit Issued | LXC CONSTRUCTION INC | 08/29/2024 |
| DOB NOW | Earth Work | Signed-off | LXC CONSTRUCTION INC | 08/29/2024 |
| DOB NOW | Plumbing | Signed-off | DW PLUMBING INC | 08/06/2024 |
| DOB NOW | Foundation | Signed-off | LXC CONSTRUCTION INC | 07/08/2024 |
| DOB NOW | General Construction | Permit Issued | LXC CONSTRUCTION INC | 06/13/2024 |
| DOB NOW | Construction Fence | Signed-off | LXC CONSTRUCTION INC | 06/06/2024 |
| BIS | OT | ISSUED | DITTA MALITO CONTRACTING, | 10/22/2008 |
| BIS | FP | ISSUED | FIREMASTERS | 02/27/2001 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/29/2026 | Signed-off | LXC CONSTRUCTION INC | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Carrier 24SCA460N301 5 tons · Condensing Unit ×1 Goodman ARUF61D14AA 4 tons · Fan Coil Indoor ×1 Ventilation Hart & Cooley 94AT 600 CFM ×2 Pennbarry DX10R 100 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/29/2026 | Signed-off | RRP PLUMBING CORP | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/29/2026 | Signed-off | TRI STATE PLBG & HTG INC | Plumbing-Sprinkler, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/12/2024 | Complete | KJK ELECTRIC INC | General Wiring |
| 11/04/2023 | Complete | A #1 UNIVERSAL ELEC'L INC | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/14/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/07/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 03/04/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 12/09/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 10/16/2024 | Certified Storm Drainage-ST-Fixtures-Finish | Certified | View ↗ |
| 10/16/2024 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 10/07/2024 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 09/27/2024 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 09/18/2024 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 09/16/2024 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 09/09/2024 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 08/23/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 08/23/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 06/29/2026 | Concrete - Cast-In-Place | XIUCHENG LI | special |
| 06/29/2026 | Fenestration air leakage | XIUCHENG LI | energy_progress |
| 06/29/2026 | Interior lighting power | XIUCHENG LI | energy_progress |
| 06/29/2026 | Air barrier - visual inspection | XIUCHENG LI | energy_progress |
| 06/29/2026 | Insulation placement and R values | XIUCHENG LI | energy_progress |
| 06/29/2026 | Fenestration and door U-factor and product ratings | XIUCHENG LI | energy_progress |
| 06/29/2026 | Fenestration areas | XIUCHENG LI | energy_progress |
| 06/29/2026 | Fire-Resistance Rated Construction | XIUCHENG LI | progress |
| 06/29/2026 | Energy Code Compliance Inspections | XIUCHENG LI | progress |
| 06/29/2026 | Subgrade Inspections | XIUCHENG LI | special |
| 06/29/2026 | Structural Stability – Alterations of existing buildings | XIUCHENG LI | special |
| 06/29/2026 | Masonry | XIUCHENG LI | special |
| 06/29/2026 | Fire-Resistant Penetrations and Joints | XIUCHENG LI | special |
| 10/01/2025 | Fenestration air leakage | XIUCHENG LI | energy_progress |
| 10/01/2025 | Interior lighting power | XIUCHENG LI | energy_progress |
| 10/01/2025 | Insulation placement and R values | XIUCHENG LI | energy_progress |
| 10/01/2025 | Fire-Resistance Rated Construction | XIUCHENG LI | progress |
| 10/01/2025 | Energy Code Compliance Inspections | XIUCHENG LI | progress |
| 10/01/2025 | Subgrade Inspections | XIUCHENG LI | special |
| 10/01/2025 | Structural Stability – Alterations of existing buildings | XIUCHENG LI | special |
| 10/01/2025 | Masonry | XIUCHENG LI | special |
| 10/01/2025 | Fire-Resistant Penetrations and Joints | XIUCHENG LI | special |
| 10/01/2025 | Concrete - Cast-In-Place | XIUCHENG LI | special |
| 10/01/2025 | Fenestration areas | XIUCHENG LI | energy_progress |
| 10/01/2025 | Air barrier - visual inspection | XIUCHENG LI | energy_progress |