← Back
Primarily 2 family with 1 store or office
5806 8 AVENUE
BROOKLYN · BIN 3016210
💬 Discuss this project
1931Year Built
3Stories
S2Building Class
R6Zoning
3,300 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: HOKAGEHUANG LLC · 1,600 sf lot · 2.06 FAR built · Flood zone X
Locations of Work
StructuralPlumbingFire Protection
Cellar7p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TO THE OWNER OF 5806 8 AV103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NIC 88 CORP302/27/2024
CL ENGINEERING P.C.208/08/2023
S M TAM ARCHITECT, PLLC101/04/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BASIC GROUPS603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PIPESTYLISTS, INCPlumbing207/08/2026
JJK BUILDING CONSULTINGGeneral Contractor107/08/2026
NY BUILDING ASSOCIATES INGeneral Contractor107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NIC 88 CORP8371302/27/2024
CL ENGINEERING P.C.6781208/08/2023
GLOBAL ARCH DESIGN & BUIL3397101/04/2023
Building Lifecycle
All (62)Filed (6)Permit Issued (5)Signed Off (5)Violation (11)Inspection (5)Objection (2)Special Inspection (28)
11/15/2024
Signed off — Alteration
REPLACE AND RELOCATE EXISTING BOILER AND H.W.H. IN THE EXISTING 3 STORY BUILDING. INSTALL NEW BOILERS AND H.W.H.. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B00961741-S3
11/15/2024
Signed off — Alteration
REPLACE AND RELOCATE EXISTING BOILER AND H.W.H. IN THE EXISTING 3 STORY BUILDING. INSTALL NEW BOILERS AND H.W.H.. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B00961741-I1
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/11/2024
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
03/07/2024
Inspection — No Access-Final Boiler Equipment Inspection
No Access
View inspection ↗
03/05/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/05/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/27/2024
Filed — Alteration
REPLACE AND RELOCATE EXISTING BOILER AND H.W.H. IN THE EXISTING 3 STORY BUILDING. INSTALL NEW BOILERS AND H.W.H.. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B00961741-S3
02/27/2024
Permit issued — Boiler Equipment
B00961741-S3-BE
02/26/2024
Filed — Alteration
REPLACE AND RELOCATE EXISTING BOILER AND H.W.H. IN THE EXISTING 3 STORY BUILDING. INSTALL NEW BOILERS AND H.W.H.. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B00961741-P1
02/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
02/26/2024
Special inspection requirement — Heating Systems
Eric Sun
02/26/2024
Special inspection requirement — Tenant Protection Plan Compliance
Eric Sun
02/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
02/26/2024
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
02/26/2024
Special inspection requirement — Tenant Protection Plan Compliance
01/24/2024
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
01/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
12/12/2023
Signed off — Alteration
CAP AND REMOVE EXISITNG GAS/PLUMBING FIXTURES AS PER PLAN IN CONJUNCTION WITH GENERAL CONSTRUCTION JOB #B00909741. NO CHANGE OF USE, OCCUPANCY OR EGRESS.
B00909744-I1
12/12/2023
Signed off — Alteration
B00909741-I1
11/22/2023
Permit issued — Plumbing
B00961741-I1-PL
11/14/2023
Filed — Alteration
REPLACE AND RELOCATE EXISTING BOILER AND H.W.H. IN THE EXISTING 3 STORY BUILDING. INSTALL NEW BOILERS AND H.W.H.. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B00961741-I1
10/05/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/24/2023
Permit issued — General Construction
B00909741-I1-GC
08/16/2023
Permit issued — Plumbing
B00909744-I1-PL
08/08/2023
Filed — Alteration
CAP AND REMOVE EXISITNG GAS/PLUMBING FIXTURES AS PER PLAN IN CONJUNCTION WITH GENERAL CONSTRUCTION JOB #B00909741. NO CHANGE OF USE, OCCUPANCY OR EGRESS.
B00909744-I1
08/08/2023
Filed — Alteration
B00909741-I1
07/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
07/25/2023
Special inspection requirement — Tenant Protection Plan Compliance
CHRISTIAN LOZADA
07/25/2023
Special inspection requirement — Fire-Resistance Rated Construction
CHRISTIAN LOZADA
07/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
07/25/2023
Special inspection requirement — Final
CHRISTIAN LOZADA
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/2023
Signed off — Alteration
B08051126-I1
04/20/2023
Permit issued — Structural
B08051126-I1-GC-CX
02/15/2023
Objection resolved — Addressed
01/09/2023
Objection raised — Other
01/04/2023
Filed — Alteration
B08051126-I1
12/15/2022
Special inspection requirement — Air barrier - visual inspection
NITHIN JOHN
12/15/2022
Special inspection requirement — Interior lighting power
NITHIN JOHN
12/15/2022
Special inspection requirement — Insulation placement and R values
NITHIN JOHN
12/15/2022
Special inspection requirement — Tenant Protection Plan Compliance
NITHIN JOHN
12/15/2022
Special inspection requirement — Structural Steel - Details
NITHIN JOHN
12/15/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
NITHIN JOHN
12/15/2022
Special inspection requirement — Concrete - Cast-In-Place
NITHIN JOHN
12/15/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
NITHIN JOHN
12/15/2022
Special inspection requirement — Masonry
NITHIN JOHN
12/15/2022
Special inspection requirement — Final
NITHIN JOHN
12/15/2022
Special inspection requirement — Footing and Foundation
NITHIN JOHN
12/15/2022
Special inspection requirement — Energy Code Compliance Inspections
NITHIN JOHN
12/15/2022
Special inspection requirement — Fire-Resistance Rated Construction
NITHIN JOHN
12/15/2022
Special inspection requirement — Preliminary
NITHIN JOHN
12/15/2022
Special inspection requirement — Lighting controls
NITHIN JOHN
07/21/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/07/2011
Violation issued (ECB, closed)
Elevators
11/02/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/07/1999
Violation issued (ECB, closed)
Construction
10/07/1999
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Latest 60 of 62 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentSigned-offT & T PLUMBING INC02/27/2024
DOB NOWPlumbingSigned-offT & T PLUMBING INC11/22/2023
DOB NOWGeneral ConstructionSigned-offNY BUILDING ASSOCIATES IN08/24/2023
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.08/16/2023
DOB NOWStructuralSigned-offJJK BUILDING CONSULTING04/20/2023
BISFPISSUEDN.Y BUSINESS FIRE SYS INC05/13/2009
BISFPISSUEDMASTER FIRE SYSTEMS, INC06/13/2002
BISMHISSUEDTRUE AIR INC.03/07/1996
BISFPISSUEDMASTER FIRE SYSTEMS, INC02/15/1996
BISPLISSUEDMAGOR PLUMBING AND HEATING01/12/1996
BISPLISSUEDMAGOR PLUMBING AND HEATING10/24/1995
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
03/11/2024Pass-Final Boiler Equipment InspectionPassView ↗
03/07/2024No Access-Final Boiler Equipment InspectionNo AccessView ↗
03/05/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/05/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/05/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
02/26/2024Fire-Resistant Penetrations and JointsEric Sunspecial
02/26/2024Heating SystemsEric Sunspecial
02/26/2024Tenant Protection Plan ComplianceEric Sunspecial
02/26/2024Fire-Resistant Penetrations and JointsEric Sunspecial
02/26/2024Energy Code Compliance InspectionsEric Sunprogress
02/26/2024Tenant Protection Plan Compliance—special
01/24/2024Energy Code Compliance InspectionsEric Sunprogress
01/24/2024Fire-Resistant Penetrations and JointsEric Sunspecial
07/25/2023Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
07/25/2023Tenant Protection Plan ComplianceCHRISTIAN LOZADAspecial
07/25/2023Fire-Resistance Rated ConstructionCHRISTIAN LOZADAprogress
07/25/2023Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
07/25/2023FinalCHRISTIAN LOZADAprogress
12/15/2022Air barrier - visual inspectionNITHIN JOHNenergy_progress
12/15/2022Interior lighting powerNITHIN JOHNenergy_progress
12/15/2022Insulation placement and R valuesNITHIN JOHNenergy_progress
12/15/2022Tenant Protection Plan ComplianceNITHIN JOHNspecial
12/15/2022Structural Steel - DetailsNITHIN JOHNspecial
12/15/2022Structural Stability – Alterations of existing buildingsNITHIN JOHNspecial
12/15/2022Concrete - Cast-In-PlaceNITHIN JOHNspecial
12/15/2022Fire-Resistant Penetrations and JointsNITHIN JOHNspecial
12/15/2022MasonryNITHIN JOHNspecial
12/15/2022FinalNITHIN JOHNprogress
12/15/2022Footing and FoundationNITHIN JOHNprogress
12/15/2022Energy Code Compliance InspectionsNITHIN JOHNprogress
Latest 25 of 28.
▾Documents — 84 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/27/2026B00909741-I1Request digital key ↗
08/27/2026B00909744-I1Request digital key ↗
08/26/2026B00961741-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION8
08/18/2025301357029Open ↗
08/15/2023310232708Open ↗
08/15/2023321069641Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION1
05/14/2009320015265Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B08051126-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B08051126-I1Open ↗
▸Seals & Professional Certifications35
▸DOB NOWProgress Inspector Seal & Signature12
09/02/2026B00961741-I1Open ↗
08/25/2026B00961741-P1Open ↗
08/24/2026B00909741-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/23/2026B00961741-S3Open ↗
09/02/2026B00961741-I1Open ↗
09/02/2026B00961741-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/27/2026B00909744-I1Open ↗
08/26/2026B00961741-I1Open ↗
08/13/2026B00909741-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
11/01/2019321994749Open ↗
11/05/2018321069641Open ↗
12/10/2008310232708Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/05/2018321069641Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
11/05/2018321069641Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes2
11/01/2019321994749Open ↗
11/05/2018321069641Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/27/2026B00909744-I1Open ↗
08/26/2026B00961741-I1Open ↗
08/13/2026B00961741-S3Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
12/10/2008310232708Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
01/10/2020321994749Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
05/11/2009320015265Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
11/01/2019321994749Open ↗
11/05/2018321069641Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY2
09/27/2023300462238Open ↗
09/27/2023300462238Open ↗
▸BIS* FINAL INSPECTION DIRECTIVE 14 OF 19751
09/27/2023300462238Open ↗
▸Approvals, Objections & Sign-offs4
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
09/28/2023300462238Open ↗
01/19/2010320015265Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
05/11/2009320015265Open ↗
12/10/2008310232708Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
11/01/2019321994749Open ↗
11/05/2018321069641Open ↗
01/19/2010320015265Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET4
11/01/2019321994749Open ↗
11/07/2018321069641Open ↗
05/11/2009320015265Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION1
03/18/2019321069641Open ↗
▸Other Documents3
▸BIS* FIRE STOPS 27-3451
09/27/2023300462238Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B08051126-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B08051126-I1Open ↗