← Back
City residence, one family
589 3 STREET
BROOKLYN · BIN 3025398
💬 Discuss this project
1911Year Built
3Stories
A4Building Class
R7BZoning
3,840 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
City residence, one family · 1,726 sf lot · 2.22 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Floor 32p · 2 filings · 8 docs
Floor 22p · 2 filings · 15 docs
Floor 12p · 2 filings · 15 docs
Basement3p · 2 filings · 15 docs
Sub-Basement1p · 1 filing · 4 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/15/2021$4.3M—— → —$1,133/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A DEGREE OF FREEDOM STRUCTURAL ENGI210/29/2021
NC2 ARCHITECTURE LLC209/03/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LLOYD NOEL BUILDING CONSULTANT403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AUSTIN PLBG & HTG CO.INCPlumbing307/08/2026
TCS CONSTRUCTION CORPGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TECNICO SPECIAL INSPECTIO5939210/29/2021
NC2 ARCHITECTURE LLC3454209/03/2021
Building Lifecycle
All (64)Filed (4)Permit Issued (5)Signed Off (1)Violation (3)Inspection (5)Objection (33)Special Inspection (13)
10/17/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/24/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/18/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/01/2022
Permit issued — Plumbing
B00523244-I1-PL
10/31/2022
Signed off — Alteration
B00523237-I1
10/12/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/03/2022
Permit issued — Plumbing
B00523244-I1-PL
09/27/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/13/2022
Permit issued — General Construction
B00523237-I1-GC
01/31/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/23/2021
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
JONATHAN BILOW
11/05/2021
Objection raised — Admin
11/05/2021
Objection resolved — Addressed
11/05/2021
Objection raised — Structural
11/05/2021
Objection resolved — Resolved
11/05/2021
Objection raised — Zoning
11/05/2021
Objection raised — Admin
11/05/2021
Objection resolved — Resolved
11/05/2021
Objection raised — Admin
11/05/2021
Objection resolved — Addressed
11/05/2021
Objection raised — Structural
11/05/2021
Objection resolved — Addressed
11/05/2021
Objection raised — Inspections
11/05/2021
Objection resolved — Addressed
10/29/2021
Filed — Alteration
Placement of Sono-tube foundations to support one-story rear deck and stair.
B00523261-S1
10/21/2021
Special inspection requirement — Concrete - Cast-In-Place
Jose Lockhart
10/21/2021
Special inspection requirement — Footing and Foundation
Jose Lockhart
10/21/2021
Special inspection requirement — Final
Jose Lockhart
10/21/2021
Special inspection requirement — Subgrade Inspections
Jose Lockhart
10/21/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Jose Lockhart
10/20/2021
Objection raised — Structural
10/20/2021
Objection resolved — Addressed
10/20/2021
Objection raised — Admin
10/20/2021
Objection resolved — Addressed
10/20/2021
Objection raised — Structural
10/20/2021
Objection resolved — Addressed
10/20/2021
Objection raised — Admin
10/20/2021
Objection resolved — Addressed
10/20/2021
Objection raised — Admin
10/20/2021
Objection resolved — Addressed
10/20/2021
Objection raised — Admin
10/20/2021
Objection resolved — Addressed
10/20/2021
Objection raised — Structural
10/20/2021
Objection resolved — Addressed
10/20/2021
Objection raised — Inspections
10/20/2021
Objection resolved — Addressed
10/20/2021
Objection raised — Inspections
10/20/2021
Objection resolved — Addressed
10/14/2021
Filed — Alteration
Placement of Sono-tube foundations to support one-story rear deck and stair.
B00523261-I1
10/14/2021
Special inspection requirement — Post-installed Anchors
Jose Lockhart
10/12/2021
Permit issued — Plumbing
B00523244-I1-PL
09/30/2021
Permit issued — General Construction
B00523237-I1-GC
09/09/2021
Objection raised — Energy
09/09/2021
Objection resolved — Addressed
09/03/2021
Filed — Alteration
Renovate existing kitchen. Reconfigure existing bathroom area on 2nd and 3rd floors. No change of use, egress or occupancy under this application.
B00523244-I1
06/01/2021
Filed — Alteration
B00523237-I1
05/26/2021
Special inspection requirement — Masonry
Jose Lockhart
05/17/2021
Special inspection requirement — Final
Jose Lockhart
05/17/2021
Special inspection requirement — Structural Steel - Welding
05/17/2021
Special inspection requirement — Structural Steel - High Strength Bolting
Jose Lockhart
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedAUSTIN PLBG & HTG CO.INC12/01/2022
DOB NOWPlumbingPermit IssuedAUSTIN PLBG & HTG CO.INC10/03/2022
DOB NOWGeneral ConstructionSigned-offTCS CONSTRUCTION CORP09/13/2022
DOB NOWPlumbingPermit IssuedAUSTIN PLBG & HTG CO.INC10/12/2021
DOB NOWGeneral ConstructionSigned-offTCS CONSTRUCTION CORP09/30/2021
1 project · most recent 09/03/2021
Gas Water/Sanitary
FiledStatusContractorScope
09/03/2021Permit IssuedAUSTIN PLBG & HTG CO.INCGas, Water/Sanitary
1 project · most recent 09/28/2022
General Wiring
FiledStatusContractorScope
09/28/2022CompleteFRIED ELECTRIC CO.General Wiring
1 project · most recent 10/29/2021
Masonry Wood
FiledStatusContractorScope
10/29/2021——Masonry, Wood
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
01/24/2023Pass-Final CND-Occupancy InspectionPassView ↗
01/18/2023Pass-Final CND-Occupancy InspectionPassView ↗
10/12/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/27/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/31/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
11/23/2021Subsurface Investigations (Borings/Test Pits)JONATHAN BILOWspecial
10/21/2021Concrete - Cast-In-PlaceJose Lockhartspecial
10/21/2021Footing and FoundationJose Lockhartprogress
10/21/2021FinalJose Lockhartprogress
10/21/2021Subgrade InspectionsJose Lockhartspecial
10/21/2021Structural Stability – Alterations of existing buildingsJose Lockhartspecial
10/14/2021Post-installed AnchorsJose Lockhartspecial
05/26/2021MasonryJose Lockhartspecial
05/17/2021FinalJose Lockhartprogress
05/17/2021Structural Steel - Welding—special
05/17/2021Structural Steel - High Strength BoltingJose Lockhartspecial
05/17/2021Structural Steel - DetailsJose Lockhartspecial
05/17/2021Structural Stability – Alterations of existing buildingsJose Lockhartspecial
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/01/2026B00523237-I1Request digital key ↗
08/15/2026B00523261-S1Request digital key ↗
08/15/2026B00523261-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits3
▸DOB NOWLPC Approval/Permit3
08/15/2026B00523261-I1Open ↗
08/13/2026B00523244-I1Open ↗
08/13/2026B00523237-I1Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/01/2026B00523237-I1Open ↗
09/01/2026B00523244-I1Open ↗
09/01/2026B00523261-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
09/05/2026B00523261-S1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/01/2026B00523237-I1Open ↗
08/15/2026B00523261-S1Open ↗
08/15/2026B00523261-I1Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports3
▸DOB NOWSOIL REPORT1
08/15/2026B00523261-S1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/15/2026B00523261-S1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/15/2026B00523261-S1Open ↗