← Back
Zoned commercial or Manhattan residential
589 EAST 161 STREET
BRONX · Morrisania · BIN 2805749
💬 Discuss this project
0Year Built
—Stories
V1Building Class
R7-2Zoning
0 sfGross Floor Area
0Units
Zoned commercial or Manhattan residential · Owner of record: HOGAR EAGLE GARDENS HOUSING DEVELOPMENT FUND CORP · 2,500 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Filed — no permit issued288p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
H.O.G.A.R., INC.703/21/2026
HOGAR EAGLE GARDENS HDFC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING1403/21/2026
Building Lifecycle
All (77)Filed (10)Objection (37)Special Inspection (30)
09/18/2026
Objection resolved — Resolved
09/17/2026
Objection raised — Fire_Protection
09/10/2026
Filed — New Building
HUB CONSULTATION HELD AND ACCEPTED ON 5/20/2025 WITH DBC RAMI BITAR. PROPOSE A NEW 11-STORY RESIDENTIAL BUILDING (USE GROUP II & IIIA) WITH A SUB-CELLAR & CELLAR AS PER PLAN. OBTAIN NEW C OF O.
X01201502-Z1
08/12/2026
Filed — New Building
HUB CONSULTATION HELD AND ACCEPTED ON 5/20/2025 WITH DBC RAMI BITAR. PROPOSE A NEW 11-STORY RESIDENTIAL BUILDING (USE GROUP II & IIIA) WITH A SUB-CELLAR & CELLAR AS PER PLAN. OBTAIN NEW C OF O.
X01201502-S7
08/05/2026
Special inspection requirement — Standpipe Systems
06/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/01/2026
Special inspection requirement — Mechanical Systems
06/01/2026
Special inspection requirement — Energy Code Compliance Inspections
06/01/2026
Special inspection requirement — Final
06/01/2026
Special inspection requirement — Maintenance information
06/01/2026
Special inspection requirement — Lighting controls
06/01/2026
Special inspection requirement — HVAC-R and service water heating equipment
06/01/2026
Special inspection requirement — Exterior lighting power
06/01/2026
Special inspection requirement — HVAC-R and service water heating system controls
06/01/2026
Special inspection requirement — Lighting in dwelling units
06/01/2026
Special inspection requirement — Interior lighting power
06/01/2026
Special inspection requirement — Electrical motors and elevators
06/01/2026
Special inspection requirement — Shutoff dampers
06/01/2026
Special inspection requirement — Duct leakage testing, insulation and design
06/01/2026
Special inspection requirement — Metering
06/01/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
05/19/2026
Filed — New Building
HUB CONSULTATION HELD AND ACCEPTED ON 5/20/2025 WITH DBC RAMI BITAR. PROPOSE A NEW 11-STORY RESIDENTIAL BUILDING (USE GROUP II & IIIA) WITH A SUB-CELLAR & CELLAR AS PER PLAN. OBTAIN NEW C OF O.
X01201502-P1
02/18/2026
Objection resolved — Resolved
02/05/2026
Objection resolved — Resolved
02/05/2026
Objection resolved — Resolved
02/05/2026
Objection resolved — Resolved
02/05/2026
Objection resolved — Resolved
01/25/2026
Objection raised — Admin
01/09/2026
Filed — New Building
HUB CONSULTATION HELD AND ACCEPTED ON 5/20/2025 WITH DBC RAMI BITAR. PROPOSE A NEW 11-STORY RESIDENTIAL BUILDING (USE GROUP II & IIIA) WITH A SUB-CELLAR & CELLAR AS PER PLAN. OBTAIN NEW C OF O.
X01201502-S6
01/05/2026
Objection resolved — Resolved
01/05/2026
Objection resolved — Resolved
12/19/2025
Objection resolved — Addressed
12/19/2025
Objection resolved — Addressed
12/19/2025
Objection resolved — Addressed
12/17/2025
Objection raised — Structural
12/17/2025
Objection raised — Structural
12/17/2025
Objection raised — Structural
12/17/2025
Objection raised — Admin
12/17/2025
Objection raised — Zoning
12/17/2025
Objection raised — Structural
12/17/2025
Objection raised — Structural
12/17/2025
Objection raised — Cost
12/17/2025
Objection raised — Structural
12/17/2025
Objection raised — Zoning
12/17/2025
Objection raised — Admin
12/17/2025
Objection raised — Structural
12/17/2025
Objection raised — Structural
12/17/2025
Objection raised — Admin
12/17/2025
Objection raised — Admin
12/17/2025
Objection raised — Zoning
12/05/2025
Objection resolved — Addressed
12/02/2025
Filed — New Building
HUB CONSULTATION HELD AND ACCEPTED ON 5/20/2025 WITH DBC RAMI BITAR. PROPOSE A NEW 11-STORY RESIDENTIAL BUILDING (USE GROUP II & IIIA) WITH A SUB-CELLAR & CELLAR AS PER PLAN. OBTAIN NEW C OF O.
X01201502-S5
12/01/2025
Filed — New Building
HUB CONSULTATION HELD AND ACCEPTED ON 5/20/2025 WITH DBC RAMI BITAR. PROPOSE A NEW 11-STORY RESIDENTIAL BUILDING (USE GROUP II & IIIA) WITH A SUB-CELLAR & CELLAR AS PER PLAN. OBTAIN NEW C OF O.
X01201502-S4
11/24/2025
Objection resolved — Addressed
10/22/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
08/04/2025
Objection raised — Admin
07/28/2025
Objection raised — Plumbing
07/28/2025
Objection raised — Scope
07/28/2025
Objection raised — Fire_Protection
07/28/2025
Objection raised — Energy
Latest 60 of 77 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISEQISSUEDFOCUS & STRUGA BUILDING DEVELOP07/13/2006
BIS—ISSUEDFOCUS & STRUGA BUILDING DEVELOP07/13/2006
BIS—ISSUEDFOCUS & STRUGA BUILDING DEVELOP11/25/2005
BISEQISSUEDFOCUS & STRUGA BUILDING DEVELOP11/25/2005
1 project · most recent 09/10/2026
Generators Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/10/2026——Generators, Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Ice Air RSXC18 17,300 BTU · Heat Pump Outdoor ×90
RSXC13 12,000 BTU · Heat Pump Outdoor ×26
RSXC09 10,200 BTU · Heat Pump Outdoor ×10
Daikin RXSQ24TAVJU 27,000 BTU · Vrf Outdoor ×2
RXTA24AAVJU 27,000 BTU · Vrf Outdoor ×2
REYA168AATJA 189,000 BTU · Vrf Outdoor ×1
REYQ016SAATJA 189,000 BTU · Vrf Outdoor ×1
Ventilation
Greenheck AX-63-275-0615 5,650 CFM · Exhaust Fan ×4
CUE-060-VG 100 CFM · Exhaust Fan ×2
CUE-095-VG 450 CFM · Exhaust Fan ×2
ERVe-35-30L 2,595 CFM · Erv ×2
BSQ-80-5 600 CFM · Exhaust Fan ×1
ERV3-35-30L 2,020 CFM · Erv ×1
SQ-7-M1-VG 600 CFM · Exhaust Fan ×1
Semco FV-3000 2,295 CFM · Erv ×3
Enervex BEF 315X 600 CFM · Exhaust Fan ×1
Generators
Generac HB-4617-1-UPS-REG-N4 23,000 BTU · Generator ×2
1 project · most recent 09/10/2026
Sprinkler System
FiledStatusContractorScope
09/10/2026——Sprinkler System
1 project · most recent 09/10/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/10/2026——Gas, Storm, Water/Sanitary
1 project · most recent 09/10/2026
Concrete Masonry
FiledStatusContractorScope
09/10/2026——Concrete, Masonry
1 project · most recent 09/10/2026
Fence Scaffold Sidewalk Shed
FiledStatusContractorScope
09/10/2026——Fence, Scaffold, Sidewalk Shed
▾Special Inspection Requirements (DOB NOW) — 36
DateRequirementInspectorRole
08/05/2026Standpipe Systems—special
06/01/2026Fire-Resistant Penetrations and Joints—special
06/01/2026Mechanical Systems—special
06/01/2026Energy Code Compliance Inspections—progress
06/01/2026Final—progress
06/01/2026Maintenance information—energy_progress
06/01/2026Lighting controls—energy_progress
06/01/2026HVAC-R and service water heating equipment—energy_progress
06/01/2026Exterior lighting power—energy_progress
06/01/2026HVAC-R and service water heating system controls—energy_progress
06/01/2026Lighting in dwelling units—energy_progress
06/01/2026Interior lighting power—energy_progress
06/01/2026Electrical motors and elevators—energy_progress
06/01/2026Shutoff dampers—energy_progress
06/01/2026Duct leakage testing, insulation and design—energy_progress
06/01/2026Metering—energy_progress
06/01/2026HVAC-R and service water piping design and insulation—energy_progress
10/22/2025Excavations - Sheeting, Shoring, and Bracing—special
05/15/2025Fenestration and door U-factor and product ratings—energy_progress
05/15/2025Insulation placement and R values—energy_progress
05/15/2025Maintenance information—energy_progress
05/15/2025Fenestration air leakage—energy_progress
05/15/2025Interior lighting power—energy_progress
05/15/2025Air barrier - visual inspection—energy_progress
05/15/2025Air barrier continuity plan testing—energy_progress
Latest 25 of 36.
▾Documents — 56 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/17/2026X01201502-S1Request digital key ↗
08/17/2026X01201502-S7Request digital key ↗
08/17/2026X01201502-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
02/18/2026240365430Open ↗
▸DOB NOWDEP Stormwater Construction Permit1
08/13/2026X01201502-I1Open ↗
▸Zoning, Tax Lot & Property Records15
▸DOB NOWRestrictive Declaration/Easement 19
09/23/2026X01201502-Z1Open ↗
08/17/2026X01201502-S1Open ↗
08/17/2026X01201502-S7Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram2
08/17/2026X01201502-I1Open ↗
08/13/2026X01201502-I1Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
02/18/2026240365430Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
02/18/2026240365430Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X01201502-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026X01201502-I1Open ↗
▸Seals & Professional Certifications15
▸DOB NOWDPL-1: Design Professional Seal & Signature12
09/23/2026X01201502-Z1Open ↗
08/17/2026X01201502-S9Open ↗
08/17/2026X01201502-S8Open ↗
Showing 3 of 12 on file for this type
▸BISAPPLICANT OWNER SIGNATURE2
02/18/2026240365430Open ↗
02/18/2026240365430Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/18/2026240365430Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST2
02/18/2026240365430Open ↗
02/18/2026240365430Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026X01201502-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/17/2026X01201502-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWOER: Notice to Proceed1
08/17/2026X01201502-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter2
08/17/2026X01201502-S7Open ↗
08/13/2026X01201502-I1Open ↗
▸Filing & Intake Forms3
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT32
02/18/2026240365430Open ↗
02/18/2026240365430Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
02/18/2026240365430Open ↗
▸Other Documents5
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
02/18/2026240365430Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
02/18/2026240365430Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026X01201502-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026X01201502-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026X01201502-I1Open ↗