← Back
Primarily 4 family with 1 store or office
593 MEEKER AVENUE
BROOKLYN · BIN 3068023
💬 Discuss this project
1920Year Built
3Stories
S4Building Class
R6Zoning
4,680 sfGross Floor Area
5Units
Rent Stabilized4 Open Violations 2 unresolved · 2 paperwork only ▸FDNY Report ↗
Primarily 4 family with 1 store or office · Owner of record: 593 MEEKER AVE LLC · 2,028 sf lot · 2.31 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 12p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
593 MEEKER AVE LLC203/22/2026
539 MEEKER AV C/O CHOICE NEW YOR203/21/2026
CHOICE NY MGMT203/21/2026
539 MEEKER AV C O CHOICE NEW YOR203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/30/2015$2.5M—— → —$524/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DRAFT MASTER ENGINEERING PC204/02/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BENJAMIN DREBINElectrical103/21/2026
VILLAGE ELECTL CONTRS INCElectrical103/22/2026
Building Lifecycle
All (84)Filed (2)Violation (60)Objection (10)Special Inspection (12)
03/09/2026
Violation issued (HPD, closed)
C
03/09/2026
Violation issued (HPD, closed)
C
03/04/2026
Violation issued (HPD, closed)
C
10/28/2025
Violation issued (HPD, closed)
B
10/28/2025
Violation issued (HPD, closed)
C
10/28/2025
Violation issued (HPD, closed)
C
10/28/2025
Violation issued (HPD, closed)
C
10/28/2025
Violation issued (HPD, closed)
B
07/02/2025
Violation issued (HPD, closed)
A
07/02/2025
Violation issued (HPD, closed)
A
06/05/2025
Objection resolved — Addressed
05/28/2025
Objection resolved — Addressed
04/29/2025
Objection resolved — Addressed
04/21/2025
Objection resolved — Addressed
04/16/2025
Objection raised — Cost
04/16/2025
Objection raised — Structural
04/03/2025
Objection raised — Plumbing
04/03/2025
Objection raised — Zoning
04/03/2025
Objection resolved — Addressed
04/03/2025
Objection raised — Plumbing
04/02/2025
Filed — Alteration
INSTALLATION OF KITCHEN EXHAUST SYSTEM AND OPENINGS FOR DUCT WORK OF EXISTING RESTAURANT
B01184631-I1
04/02/2025
Filed — Alteration
INSTALLATION OF KITCHEN EXHAUST SYSTEM AND OPENINGS FOR DUCT WORK OF EXISTING RESTAURANT
B01184631-S1
04/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/02/2025
Special inspection requirement — Tenant Protection Plan Compliance
04/02/2025
Special inspection requirement — Energy Code Compliance Inspections
03/21/2025
Special inspection requirement — Tenant Protection Plan Compliance
02/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
02/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/21/2025
Special inspection requirement — HVAC-R and service water heating equipment
02/21/2025
Special inspection requirement — HVAC-R and service water heating system controls
02/21/2025
Special inspection requirement — Maintenance information
02/21/2025
Special inspection requirement — Mechanical Systems
02/21/2025
Special inspection requirement — Energy Code Compliance Inspections
02/21/2025
Special inspection requirement — Final
03/27/2022
Violation issued (HPD, closed)
B
03/27/2022
Violation issued (HPD, closed)
A
03/01/2022
Violation issued (HPD, closed)
A
12/23/2021
Violation issued (HPD, closed)
B
12/23/2021
Violation issued (HPD, closed)
C
12/22/2021
Violation issued (HPD, closed)
A
12/22/2021
Violation issued (HPD, closed)
C
12/22/2021
Violation issued (HPD, closed)
B
12/22/2021
Violation issued (HPD, closed)
B
12/14/2021
Violation issued (HPD, closed)
C
12/14/2021
Violation issued (HPD, closed)
C
09/22/2021
Violation issued (HPD, closed)
A
09/22/2021
Violation issued (HPD, closed)
A
09/22/2021
Violation issued (HPD, closed)
C
09/22/2021
Violation issued (HPD, closed)
A
09/22/2021
Violation issued (HPD, closed)
A
09/22/2021
Violation issued (HPD, closed)
A
09/22/2021
Violation issued (HPD, closed)
B
09/13/2021
Violation issued (HPD, closed)
B
09/13/2021
Violation issued (HPD, closed)
C
09/13/2021
Violation issued (HPD, closed)
C
09/13/2021
Violation issued (HPD, closed)
A
09/13/2021
Violation issued (HPD, closed)
A
08/30/2021
Violation issued (HPD, closed)
C
08/30/2021
Violation issued (HPD, closed)
B
08/30/2021
Violation issued (HPD, closed)
C
Latest 60 of 84 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDA L ONE INC12/14/2015
BISPLISSUEDARCO PLBG AND HTG INC11/02/2015
BISOTISSUEDA L ONE INC10/08/2015
BISFPISSUEDFIRE COMMAND CO, INC11/24/2010
BISBLISSUEDOLYMPIAN FUEL OIL CORP.02/24/2006
BISOTISSUEDTRICE RESTORATION CORP04/14/2003
BISFPISSUEDFIRE OUT COR�08/06/1999
1 project · most recent 04/02/2025
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/02/2025——Ventilation Systems
Ventilation
Captiveaire NCA18FA 4,800 CFM · Kitchen Exhaust ×1
1 project · most recent 04/02/2025
Gas
FiledStatusContractorScope
04/02/2025——Gas
3 projects · most recent 06/29/2022
General Wiring
FiledStatusContractorScope
06/29/2022Permit IssuedVILLAGE ELECTL CONTRS INCGeneral Wiring
06/21/2022CompleteVILLAGE ELECTL CONTRS INC—
06/15/2022CompleteVILLAGE ELECTL CONTRS INC—
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
04/02/2025Fire-Resistant Penetrations and Joints—special
04/02/2025Tenant Protection Plan Compliance—special
04/02/2025Energy Code Compliance Inspections—progress
03/21/2025Tenant Protection Plan Compliance—special
02/21/2025HVAC-R and service water piping design and insulation—energy_progress
02/21/2025Fire-Resistant Penetrations and Joints—special
02/21/2025HVAC-R and service water heating equipment—energy_progress
02/21/2025HVAC-R and service water heating system controls—energy_progress
02/21/2025Maintenance information—energy_progress
02/21/2025Mechanical Systems—special
02/21/2025Energy Code Compliance Inspections—progress
02/21/2025Final—progress
▾Documents — 44 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/22/2026B01184631-S1Request digital key ↗
08/22/2026B01184631-I1Request digital key ↗
▸Applications & Permits10
▸BISPLAN / WORK APPROVAL APPLICATION5
10/12/2016321276169Open ↗
10/12/2016321233054Open ↗
11/24/2015321276169Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION4
12/21/2015321276169Open ↗
11/18/2015321233054Open ↗
10/09/2015321233054Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
03/25/2016321233054Open ↗
▸Seals & Professional Certifications10
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
11/24/2015321276169Open ↗
09/11/2015321233054Open ↗
11/26/2010320215995Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
11/24/2015321276169Open ↗
09/11/2015321233054Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
11/24/2015321276169Open ↗
09/11/2015321233054Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B01184631-I1Open ↗
08/13/2026B01184631-S1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
11/24/2015321276169Open ↗
09/11/2015321233054Open ↗
▸BISSCHEDULE B - PLUMBING1
09/20/2010320215995Open ↗
▸Environmental & Asbestos6
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
01/12/2011320215995Open ↗
09/20/2010320215995Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
11/24/2015321276169Open ↗
09/11/2015321233054Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B01184631-I1Open ↗
08/13/2026B01184631-S1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
11/24/2015321276169Open ↗
09/11/2015321233054Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
09/20/2010320215995Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT3
11/24/2015321276169Open ↗
09/11/2015321233054Open ↗
09/20/2010320215995Open ↗
▸BISHIC LICENSE OR AFFIDAVIT2
12/21/2015321276169Open ↗
10/09/2015321233054Open ↗
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET3
11/24/2015321276169Open ↗
09/11/2015321233054Open ↗
09/20/2010320215995Open ↗
▸BISADDITIONAL INFORMATION2
10/12/2016321233054Open ↗
10/12/2016321276169Open ↗