← Back
Miscellaneous two family
594 COURT STREET
💬 Discuss this project
1901Year Built
2Stories
B9Building Class
M1-1Zoning
1,680 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Miscellaneous two family · Owner of record: COURT GARDEN HOLDINGS LLC · 2,000 sf lot · 0.84 FAR built · Flood zone X500
Locations of Work
ArchitecturePlumbingEquipmentGeneral
Floor 27p · 1 filing · 14 docs
Floor 15p · 1 filing · 14 docs
Sub-Basement5p · 1 filing · 14 docs
Site & exterior3p · 1 filing · 2 docs
Filed — no permit issued4p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNERS REP507/08/2026
BIG DREAM DEVELOPERS503/22/2026
TOP QUALITY MANAGEMENT407/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/14/2021$780K—Private party → MAZEL COURT LLC$464/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NIKOLAI KATZ ARCHITECT308/24/2023
PAUL PERDEK, PROF. ENG. PLLC211/18/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AE DESIGN SOLUTION403/21/2026
RELIABLE EXPEDITING303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YL CONSTRUCTION ADVISERGeneral Contractor303/21/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor207/08/2026
PLBG P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616208/24/2023
Building Lifecycle
All (45)Filed (5)Permit Issued (4)Signed Off (3)Violation (6)Inspection (4)Objection (10)Special Inspection (13)
06/27/2024
Signed off — Alteration
Plumbing application herewith filed for fixture replacement in conjunction with GC Application no. B00765911-S1
B00765911-I1
06/27/2024
Signed off — Alteration
Plumbing application herewith filed for fixture replacement in conjunction with GC Application no. B00765911-S1
B00765911-S1
06/21/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/21/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/30/2024
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
05/30/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/06/2023
Violation issued (ECB, closed)
Construction
10/10/2023
Permit issued — General Construction
B00765911-I1-GC
10/10/2023
Permit issued — Plumbing
B00765911-S1-PL
09/03/2023
Objection resolved — Addressed
09/03/2023
Objection resolved — Addressed
09/03/2023
Objection resolved — Addressed
08/31/2023
Objection raised — Admin
08/31/2023
Objection raised — Admin
08/31/2023
Objection raised — Other
08/24/2023
Filed — Alteration
Plumbing application herewith filed for fixture replacement in conjunction with GC Application no. B00765911-S1
B00765911-S1
08/23/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
08/11/2023
Signed off — Alteration
B00633757-I1
08/03/2023
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
08/03/2023
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
08/03/2023
Special inspection requirement — Final
FAHAD FATEH
08/03/2023
Special inspection requirement — Lighting in dwelling units
FAHAD FATEH
08/03/2023
Special inspection requirement — Interior lighting power
FAHAD FATEH
08/03/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
06/21/2023
Filed — Alteration
Plumbing application herewith filed for fixture replacement in conjunction with GC Application no. B00765911-S1
B00765911-P1
06/21/2023
Special inspection requirement — Energy Code Compliance Inspections
06/21/2023
Special inspection requirement — Final
06/21/2023
Special inspection requirement — Fire-Resistance Rated Construction
06/21/2023
Special inspection requirement — Interior lighting power
06/21/2023
Special inspection requirement — Lighting in dwelling units
06/21/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/11/2023
Violation issued (ECB, closed)
Construction
01/31/2023
Violation issued (ECB, closed)
Construction
12/05/2022
Violation issued (ECB, closed)
Construction
11/15/2022
Permit issued — Sidewalk Shed
B00633757-I1-SH
06/30/2022
Filed — Alteration
Plumbing application herewith filed for fixture replacement in conjunction with GC Application no. B00765911-S1
B00765911-I1
11/19/2021
Permit issued — Sidewalk Shed
B00633757-I1-SH
11/19/2021
Objection raised — Scope
11/19/2021
Objection raised — Inspections
11/19/2021
Objection raised — Inspections
11/19/2021
Objection raised — Structural
11/18/2021
Filed — Alteration
B00633757-I1
11/18/2021
Filed — Alteration
INSTALLATION OF TEMPORARY FENCE AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00633708-I1
11/17/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/15/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offYL CONSTRUCTION ADVISER10/10/2023
DOB NOWPlumbingSigned-offPLBG P & H INC10/10/2023
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC11/15/2022
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC11/19/2021
1 project · most recent 11/18/2021
FiledStatusContractorScope
11/18/2021CompleteV. VASS ELECTRIC CORP—
1 project · most recent 11/18/2021
Fence
FiledStatusContractorScope
11/18/2021——Fence
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
06/21/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/21/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/30/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
05/30/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
08/23/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
08/03/2023Fire-Resistance Rated ConstructionFAHAD FATEHprogress
08/03/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
08/03/2023FinalFAHAD FATEHprogress
08/03/2023Lighting in dwelling unitsFAHAD FATEHenergy_progress
08/03/2023Interior lighting powerFAHAD FATEHenergy_progress
08/03/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
06/21/2023Energy Code Compliance Inspections—progress
06/21/2023Final—progress
06/21/2023Fire-Resistance Rated Construction—progress
06/21/2023Interior lighting power—energy_progress
06/21/2023Lighting in dwelling units—energy_progress
06/21/2023Fire-Resistant Penetrations and Joints—special
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/31/2026B00633708-I1Request digital key ↗
08/31/2026B00633757-I1Request digital key ↗
08/29/2026B00765911-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/31/2026B00633757-I1Open ↗
08/29/2026B00765911-S1Open ↗
08/29/2026B00765911-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026B00765911-I1Open ↗
08/23/2026B00765911-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026B00765911-S1Open ↗
08/23/2026B00765911-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/29/2026B00765911-S1Open ↗
08/29/2026B00765911-I1Open ↗
08/29/2026B00765911-P1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/29/2026B00765911-I1Open ↗