ECB12/23/2025FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR SUMMONS # 39129728N., FILE A CERTIFICATE OF CORRECTION$6K due
DOB11/07/2024FAILURE TO MAINTAIN.BLDG SFFRD A FIRE ON 11/3/24&ONE ROOF TRUSS CHORD WAS FIRE DMGD.UNRELATD TO FIRE,TRUSS BOTTOM CHRDS/TIES FRM EXP2(NORTH) TO EXP4(SOUTH)WERE PREV REMOVD.EXP2&4 WALLS LEANING.1.NYSPE STRCTRL ENG TO IMMED EVAL THE ENT BLDG&DSGN RPAIRS,2.FILE FOR RPAIRS BY 3/10/25,3.OBTN PRMTS&STRT WRK BY 3/24/25
DOB11/07/2024STRUCTURE RENDERED NON COMPLAINT. OBSERVED SECTION OF TIE BEAM CHARRED WHICH SUPPORTING METAL RODS PARTIALLY ROOF AND EXP#2 AND 4 WALL .DUE TO FIRE. VACATE ENTIRE BUILDING.
DOB11/07/2024EMERGENCY WORK.BLDG SFFRD A FIRE ON 11/3/24.UNRELATED TO FIRE, HORIZONTL BEAMS PREV RMVD@TRUSS LOCATIONS.EXP2(NORTH)&EXP4(SOUTH)WALLS LEANING OUTWRD@TOP.OBSRVD DTERIORATD WOOD FRAMNG@EMBEDDED INEXP2 1.IMMED INSTLL TEMP SHORNG&BRACNG&TEMP HORIZONTL BEAMS@DIRECTN OF NYSPE STRCTRL ENG,2.ALL WRK TO BE DRCTLY SPRVSD
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB02/13/2004V-DOB VIOLATION - ACTIVE
DOB03/19/2003V-DOB VIOLATION - ACTIVE
DOB03/26/2002V-DOB VIOLATION - ACTIVE
DOB05/04/1998V-DOB VIOLATION - ACTIVE
ECB11/07/2024AT TIME OF INSPECTION OBSERVED AT CELLAR LEVEL EXIT PASSAGEWAY OBSTRUCTED BY COMBUSTIBLE MATERIALS AND HOUSEHOLD ITEMS., REPAIR AND/OR REPLACEHearing held — result not yet published$655 proposed
ECB11/07/2024AT TIME OF INSPECTION OBSERVED EXP#2,3,AND 4 WALL HAVE CRACKS AT MULTIPLE LOCATIONS, EXP#2 AND 4 WALL BULGING. ALSO AT EXP#4 FRAMING BEAM DISPLACED PUSHING BRICK WALL OUTWARD., MAINTAIN EXTERIOR BUILDING WALLHearing held — result not yet published$3K proposed
Church, synagogue, chapel · Owner of record: METRO NEW YORK DISTRICT CHURCH OF THE NA ZARENE · 4,246 sf lot · 0.57 FAR built · Flood zone X