← Back
Large suburban residence
6 SMYRNA AVENUE
STATEN ISLAND · Arden Heights-Rossville · BIN 5075833
💬 Discuss this project
1975Year Built
1Stories
A3Building Class
R3-1Zoning
5,004 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Large suburban residence · 11,220 sf lot · 0.45 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingFire ProtectionGeneral
Floor 213p · 1 filing · 20 docs
Floor 133p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GBI CONTRACTING303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROGERS CALVANICO GROUP PLLC1011/22/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GBI CONTRACTING, LLCGeneral Contractor1203/21/2026
AMBER ELECTL CONTNG INCElectrical203/22/2026
EH PLUMBING & HEATING CORPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738410/05/2023
Building Lifecycle
All (70)Filed (10)Permit Issued (8)Signed Off (2)Violation (5)Inspection (9)Objection (6)Special Inspection (30)
04/18/2024
Signed off — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL EXTENSTION TO EXISTING (1) STORY RESIDENCE. ADD 2ND FLR; ADD NEW FOUNDATION & FOOTING. REPLACE EXISTING CEILING & ROOF WITH NEW. INCREASE IN FLOOR AREA. CHANGE IN BLDG HT; NO CHANGE INUSE, NEW C OF O REQUIRED.
S00613530-S1
12/05/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/24/2023
Permit issued — Mechanical Systems
S00613530-I1-ST
11/24/2023
Permit issued — Mechanical Systems
S00613530-I1-MS
11/22/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL EXTENSTION TO EXISTING (1) STORY RESIDENCE. ADD 2ND FLR; ADD NEW FOUNDATION & FOOTING. REPLACE EXISTING CEILING & ROOF WITH NEW. INCREASE IN FLOOR AREA. CHANGE IN BLDG HT; NO CHANGE INUSE, NEW C OF O REQUIRED.
S00613530-P8
11/03/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/20/2023
Inspection — Certified Gas-Gas-Piping-Underground
Certified
View inspection ↗
10/18/2023
Special inspection requirement — Protection of exposed foundation insulation
anthony santoro
10/18/2023
Special inspection requirement — HVAC-R and service water heating system controls
anthony santoro
10/18/2023
Special inspection requirement — Concrete - Cast-In-Place
anthony santoro
10/18/2023
Special inspection requirement — HVAC-R and service water heating equipment
anthony santoro
10/18/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
anthony santoro
10/18/2023
Special inspection requirement — Permanent certificate
anthony santoro
10/18/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
anthony santoro
10/18/2023
Special inspection requirement — Wood – Prefabricated I-Joists
anthony santoro
10/18/2023
Special inspection requirement — Footing and Foundation
anthony santoro
10/18/2023
Special inspection requirement — Structural Wood Frame
anthony santoro
10/18/2023
Special inspection requirement — Ventilation and air distribution system
anthony santoro
10/18/2023
Special inspection requirement — Fenestration air leakage
anthony santoro
10/18/2023
Special inspection requirement — Metering
anthony santoro
10/18/2023
Special inspection requirement — Maintenance information
anthony santoro
10/18/2023
Special inspection requirement — Mechanical Systems
anthony santoro
10/18/2023
Special inspection requirement — Structural Steel - Welding
anthony santoro
10/18/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
anthony santoro
10/18/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
anthony santoro
10/18/2023
Special inspection requirement — Subgrade Inspections
anthony santoro
10/18/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
anthony santoro
10/18/2023
Special inspection requirement — Final
anthony santoro
10/18/2023
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
10/18/2023
Special inspection requirement — Fenestration areas
anthony santoro
10/18/2023
Special inspection requirement — Interior lighting power
anthony santoro
10/18/2023
Special inspection requirement — Insulation placement and R values
anthony santoro
10/18/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
anthony santoro
10/18/2023
Special inspection requirement — Duct leakage testing, insulation and design
anthony santoro
10/18/2023
Special inspection requirement — Air barrier - visual inspection
anthony santoro
10/18/2023
Special inspection requirement — Structural Steel - Details
anthony santoro
10/17/2023
Permit issued — Plumbing
S00613530-S1-PL
10/16/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/05/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL EXTENSTION TO EXISTING (1) STORY RESIDENCE. ADD 2ND FLR; ADD NEW FOUNDATION & FOOTING. REPLACE EXISTING CEILING & ROOF WITH NEW. INCREASE IN FLOOR AREA. CHANGE IN BLDG HT; NO CHANGE INUSE, NEW C OF O REQUIRED.
S00613530-P6
10/05/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL EXTENSTION TO EXISTING (1) STORY RESIDENCE. ADD 2ND FLR; ADD NEW FOUNDATION & FOOTING. REPLACE EXISTING CEILING & ROOF WITH NEW. INCREASE IN FLOOR AREA. CHANGE IN BLDG HT; NO CHANGE INUSE, NEW C OF O REQUIRED.
S00613530-P7
10/05/2023
Signed off — Alteration
S00611813-I1
10/03/2023
Special inspection requirement — Interior lighting power
anthony santoro
05/29/2023
Violation issued (ECB, closed)
Construction
05/23/2023
Violation issued (ECB, closed)
Construction
05/23/2023
Violation issued (ECB, closed)
Construction
03/27/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/23/2023
Permit issued — General Construction
S00613530-I1-GC-CX
02/14/2023
Permit issued — Construction Fence
S00611813-I1-FN
10/24/2022
Inspection — Pass-Final House Connection
Pass
View inspection ↗
08/03/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL EXTENSTION TO EXISTING (1) STORY RESIDENCE. ADD 2ND FLR; ADD NEW FOUNDATION & FOOTING. REPLACE EXISTING CEILING & ROOF WITH NEW. INCREASE IN FLOOR AREA. CHANGE IN BLDG HT; NO CHANGE INUSE, NEW C OF O REQUIRED.
S00613530-P4
07/22/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/18/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL EXTENSTION TO EXISTING (1) STORY RESIDENCE. ADD 2ND FLR; ADD NEW FOUNDATION & FOOTING. REPLACE EXISTING CEILING & ROOF WITH NEW. INCREASE IN FLOOR AREA. CHANGE IN BLDG HT; NO CHANGE INUSE, NEW C OF O REQUIRED.
S00613530-P5
06/07/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/07/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/31/2022
Permit issued — Plumbing
S00613530-S1-PL
05/10/2022
Objection resolved — Addressed
05/10/2022
Objection resolved — Addressed
05/03/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/29/2022
Objection raised — Scope
04/29/2022
Objection raised — Scope
Latest 60 of 70 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offGBI CONTRACTING, LLC11/24/2023
DOB NOWMechanical SystemsSigned-offGBI CONTRACTING, LLC11/24/2023
DOB NOWPlumbingSigned-offEH PLUMBING & HEATING COR10/17/2023
DOB NOWGeneral ConstructionPermit IssuedGBI CONTRACTING, LLC02/23/2023
DOB NOWConstruction FenceSigned-offGBI CONTRACTING, LLC02/14/2023
DOB NOWPlumbingSigned-offEH PLUMBING & HEATING COR05/31/2022
DOB NOWGeneral ConstructionPermit IssuedGBI CONTRACTING, LLC03/01/2022
DOB NOWConstruction FenceSigned-offGBI CONTRACTING, LLC02/14/2022
BISOTISSUEDFICAZZOLA CONSULTING LLC03/21/2023
BISOTISSUEDN/A03/30/2004
BISOTISSUEDJOHN MICHAELS CONTRACTING CORP.09/30/2003
1 project · most recent 11/22/2023
Gas Water/Sanitary
FiledStatusContractorScope
11/22/2023Signed-offEH PLUMBING & HEATING CORGas, Water/Sanitary
3 projects · most recent 05/24/2023
General Wiring
FiledStatusContractorScope
05/24/2023CompleteAMBER ELECTL CONTNG INC—
02/21/2023CompleteSOLID STATE ELECTRIC LLCGeneral Wiring
03/20/2022CompleteSOLID STATE ELECTRIC LLC—
1 project · most recent 11/22/2023
Wood
FiledStatusContractorScope
11/22/2023Signed-offGBI CONTRACTING, LLCWood
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
12/05/2023Pass-Final CND-Occupancy InspectionPassView ↗
11/03/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/20/2023Certified Gas-Gas-Piping-UndergroundCertifiedView ↗
10/16/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/27/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/24/2022Pass-Final House ConnectionPassView ↗
07/22/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/03/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/22/2022Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 87
DateRequirementInspectorRole
10/18/2023Structural Steel - Detailsanthony santorospecial
10/18/2023Mechanical Systemsanthony santorospecial
10/18/2023Structural Steel - Weldinganthony santorospecial
10/18/2023Subsurface Investigations (Borings/Test Pits)anthony santorospecial
10/18/2023Exterior Insulation and Finish Systems (EIFS)anthony santorospecial
10/18/2023Structural Stability – Alterations of existing buildingsanthony santorospecial
10/18/2023Wood – Prefabricated I-Joistsanthony santorospecial
10/18/2023Concrete - Cast-In-Placeanthony santorospecial
10/18/2023Subgrade Inspectionsanthony santorospecial
10/18/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installationanthony santorospecial
10/18/2023Footing and Foundationanthony santoroprogress
10/18/2023Finalanthony santoroprogress
10/18/2023Energy Code Compliance Inspectionsanthony santoroprogress
10/18/2023Structural Wood Frameanthony santoroprogress
10/18/2023HVAC-R and service water heating equipmentanthony santoroenergy_progress
10/18/2023Protection of exposed foundation insulationanthony santoroenergy_progress
10/18/2023Fenestration areasanthony santoroenergy_progress
10/18/2023Interior lighting poweranthony santoroenergy_progress
10/18/2023Ventilation and air distribution systemanthony santoroenergy_progress
10/18/2023Insulation placement and R valuesanthony santoroenergy_progress
10/18/2023HVAC-R and service water piping design and insulationanthony santoroenergy_progress
10/18/2023Fenestration air leakageanthony santoroenergy_progress
10/18/2023Fenestration and door U-factor and product ratingsanthony santoroenergy_progress
10/18/2023Duct leakage testing, insulation and designanthony santoroenergy_progress
10/18/2023Air barrier - visual inspectionanthony santoroenergy_progress
Latest 25 of 87.
▾Documents — 116 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/25/2026S00611813-I1Request digital key ↗
08/22/2026S00613530-P8Request digital key ↗
08/22/2026S00613530-P7Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
05/19/2023540246456Open ↗
03/10/2023540246456Open ↗
12/17/2021540211340Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
08/02/2022540211340Open ↗
▸BISWORK PERMIT APPLICATION1
03/21/2023540246456Open ↗
▸Zoning, Tax Lot & Property Records8
▸DOB NOWZoning Exhibit form (1-5)4
08/13/2026S00613530-P6Open ↗
08/13/2026S00613530-P5Open ↗
08/13/2026S00613530-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026S00613530-P6Open ↗
08/13/2026S00613530-P5Open ↗
08/13/2026S00613530-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00613530-I1Open ↗
▸Seals & Professional Certifications32
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/25/2026S00611813-I1Open ↗
08/13/2026S00613530-I1Open ↗
08/13/2026S00613530-P7Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
08/26/2026S00613530-P6Open ↗
08/26/2026S00613530-P6Open ↗
08/26/2026S00613530-P6Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
08/26/2026S00613530-P6Open ↗
08/26/2026S00613530-P6Open ↗
08/26/2026S00613530-P6Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
03/10/2023540246456Open ↗
12/17/2021540211340Open ↗
▸BISAPPLICANT OWNER SIGNATURE2
03/10/2023540246456Open ↗
12/17/2021540211340Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE SUPPORTING DOCUMENT1
12/17/2021540211340Open ↗
▸BISTPP1: TENANT PROTECTION PLAN1
03/21/2023540246456Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026S00613530-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026S00613530-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/13/2026S00613530-P8Open ↗
08/13/2026S00613530-P7Open ↗
08/13/2026S00613530-S1Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
07/05/2023540246456Open ↗
03/10/2023540246456Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
07/05/2023540246456Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
03/10/2023540246456Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
07/05/2023540246456Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
03/10/2023540246456Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026S00613530-I1Open ↗
▸Inspections & Test Reports10
▸DOB NOWSOIL REPORT4
08/13/2026S00613530-P1Open ↗
08/13/2026S00613530-P6Open ↗
08/13/2026S00613530-P5Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY3
07/05/2023540246456Open ↗
03/10/2023540246456Open ↗
12/17/2021540211340Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
12/17/2021540211340Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00613530-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026S00613530-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
12/17/2021540211340Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/06/2023540246456Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
07/06/2023540246456Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT (FINAL): PW31
07/05/2023540246456Open ↗
▸BISCOST AFFIDAVIT1
03/10/2023540246456Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
06/22/2023540246456Open ↗
03/17/2023540246456Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
03/10/2023540246456Open ↗
12/17/2021540211340Open ↗
▸Other Documents22
▸DOB NOWProperty Ownership Certification6
08/13/2026S00613530-I1Open ↗
08/13/2026S00613530-P1Open ↗
08/13/2026S00613530-P3Open ↗
Showing 3 of 6 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION4
08/02/2022540211340Open ↗
08/02/2022540211340Open ↗
08/02/2022540211340Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026S00613530-I1Open ↗
08/13/2026S00613530-P1Open ↗
08/13/2026S00613530-P5Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSite Survey: Initial3
08/13/2026S00613530-P6Open ↗
08/13/2026S00613530-P5Open ↗
08/13/2026S00613530-I1Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION2
07/06/2023540246456Open ↗
07/06/2023540246456Open ↗
▸BISBPP - DOT Builders Pavement Unit Waiver Request Form1
12/17/2021540211340Open ↗
▸BISWAIVER OF CURB ALIGNMENT FOR BOTH STREET1
08/02/2022540211340Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026S00613530-I1Open ↗