← Back
Two family brick
60-20 71 AVENUE
QUEENS · BIN 4084482
💬 Discuss this project
1911Year Built
2Stories
B1Building Class
R6BZoning
2,970 sfGross Floor Area
2Units
1 Open Violation ▸
Two family brick · Owner of record: 60-20 AEB LLC · 1,600 sf lot · 1.86 FAR built · Flood zone X
Locations of Work
Floor 11p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
60-20 AEB1607/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/02/2022$885K—— → —$298/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SCA CODE CONSULTING AND PLANNING407/02/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SCACODECONSULTINGANDPLANNING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FIRST QUOTE CONTRACTING IGeneral Contractor407/08/2026
VEEVA CONSTRUCTION J INCGeneral Contractor303/21/2026
MES CONSTRUCTION CORPPlumbing107/08/2026
PLUMB-IT MECHANICAL INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SCA CODE AND PLANNING, LL6599407/02/2024
Building Lifecycle
All (19)Filed (4)Permit Issued (5)Signed Off (2)Violation (2)Inspection (4)Special Inspection (2)
11/18/2024
Signed off — Alteration
MISC.RENO OF EXISTING 2-FAMILY, WORK TO INCLUDE REMOVAL OF NON-LOAD BEARING WALLS, NEW KITCHEN &BATHROOM FINISHES. NEW EXHAUST VENT FOR STOVE AND DRYER. FILLING TO ADRESS ECB#34260152L. PL TO BE FILED WITHDOBNOW. NO CHANGE IN USE, EGRESS NOR OCCUPANCY.
Q08033337-I1
11/18/2024
Signed off — Alteration
Filling for plumbing work in conjunction with DOB# Q08033337 Alt2 application for interior reno and make corrections for DOB violation# 34260152L. No change in use, egress nor occupancy.
Q08033440-I1
11/14/2024
Permit issued — Mechanical Systems
Q08033337-I1-MS
07/09/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JOMO CHARLES
07/02/2024
Filed — Alteration
Filling for plumbing work in conjunction with DOB# Q08033337 Alt2 application for interior reno and make corrections for DOB violation# 34260152L. No change in use, egress nor occupancy.
Q08033440-P2
06/17/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JOMO CHARLES
05/17/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/06/2024
Permit issued — General Construction
Q08033337-I1-GC
05/01/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/23/2024
Permit issued — Plumbing
Q08033440-I1-PL
10/13/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/19/2023
Filed — Alteration
Filling for plumbing work in conjunction with DOB# Q08033337 Alt2 application for interior reno and make corrections for DOB violation# 34260152L. No change in use, egress nor occupancy.
Q08033440-P1
04/21/2023
Permit issued — Plumbing
Q08033440-I1-PL
03/09/2023
Permit issued — Mechanical Systems
Q08033337-I1-GC
11/11/2022
Filed — Alteration
MISC.RENO OF EXISTING 2-FAMILY, WORK TO INCLUDE REMOVAL OF NON-LOAD BEARING WALLS, NEW KITCHEN &BATHROOM FINISHES. NEW EXHAUST VENT FOR STOVE AND DRYER. FILLING TO ADRESS ECB#34260152L. PL TO BE FILED WITHDOBNOW. NO CHANGE IN USE, EGRESS NOR OCCUPANCY.
Q08033337-I1
11/11/2022
Filed — Alteration
Filling for plumbing work in conjunction with DOB# Q08033337 Alt2 application for interior reno and make corrections for DOB violation# 34260152L. No change in use, egress nor occupancy.
Q08033440-I1
10/05/2000
Violation issued (ECB, closed)
Quality of Life
10/05/2000
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offFIRST QUOTE CONTRACTING I11/14/2024
DOB NOWGeneral ConstructionSigned-offFIRST QUOTE CONTRACTING I05/06/2024
DOB NOWPlumbingSigned-offJVR PLBG AND HEATING INC04/23/2024
DOB NOWPlumbingSigned-offMES CONSTRUCTION CORP04/21/2023
DOB NOWMechanical SystemsSigned-offVEEVA CONSTRUCTION J INC03/09/2023
2 projects · most recent 04/24/2024
General Wiring
FiledStatusContractorScope
04/24/2024CompleteKRISCORP ELECL CONTNG INCGeneral Wiring
04/07/2023CompleteGOODALL ELECTRIC CORP—
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/09/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/17/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/01/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/13/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
07/05/2024Fire-Resistant Penetrations and JointsJOMO CHARLESspecial
06/17/2024Fire-Resistant Penetrations and JointsJOMO CHARLESspecial
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/25/2026Q08033337-I1Request digital key ↗
08/24/2026Q08033440-P2Request digital key ↗
08/24/2026Q08033440-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits4
▸DOB NOWLPC Approval/Permit4
08/13/2026Q08033337-I1Open ↗
08/13/2026Q08033440-I1Open ↗
08/13/2026Q08033440-P2Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/24/2026Q08033440-P1Open ↗
08/24/2026Q08033440-I1Open ↗
08/24/2026Q08033440-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q08033440-I1Open ↗
08/24/2026Q08033440-P2Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/24/2026Q08033440-P1Open ↗
08/24/2026Q08033440-I1Open ↗
08/24/2026Q08033440-P2Open ↗
Showing 3 of 4 on file for this type