| Owner | Filings | Most Recent |
|---|---|---|
| NEW AMERICAN CONSTRUCTION INC | 8 | 09/13/2026 |
| LE CAPITAL NYC | 17 | 09/13/2026 |
| 60 BOX STREET | 10 | 07/08/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 03/27/2025 | $2.8M | — | 60 BOX STREET LLC → BOX CONDOMINIUMS LLC | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| STUDIOSC ARCHITECTURE PLLC | 4 | 07/08/2026 |
| MCHENERY TESTING LAB | 4 | 06/09/2026 |
| JOEL PHAGOO P.E. PLLC | 2 | 06/02/2026 |
| STRUCTURAL ENGINEERING TECHNOLOGIES | 2 | 04/29/2025 |
| STROH ENGINEERING SERVICES, P.C. | 1 | 04/24/2025 |
| ALL CITY ENGINEERING, P.C. | 3 | 03/28/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| NEW AMERICAN CONSTRUCTION INC | 2 | 03/21/2026 |
| BMB BUILDING CONSULTING | 16 | 03/21/2026 |
| AC EXPEDITING | 1 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| H BUILDING MANAGEMENT INC | General Contractor | 13 | 09/07/2026 |
| NEW AMERICAN CONSTRUCTION INC | General Contractor | 4 | 09/09/2026 |
| RRP PLUMBING CORP | Fire Protection | 1 | 07/01/2026 |
| RRP PLUMBING CORP | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| HRF SERVICES CORP | 5616 | 9 | 07/08/2026 |
| JOEL PHAGOO ,PE, PLLC | 2416 | 2 | 06/02/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sidewalk Shed | Permit Issued | NEW AMERICAN CONSTRUCTION INC | 09/08/2026 |
| DOB NOW | General Construction | Permit Issued | H BUILDING MANAGEMENT INC | 09/03/2026 |
| DOB NOW | Sprinklers | Permit Issued | RRP PLUMBING CORP | 06/29/2026 |
| DOB NOW | Construction Fence | Permit Issued | H BUILDING MANAGEMENT INC | 06/26/2026 |
| DOB NOW | Sidewalk Shed | Permit Issued | NEW AMERICAN CONSTRUCTION INC | 06/08/2026 |
| DOB NOW | Supported Scaffold | Permit Issued | H BUILDING MANAGEMENT INC | 05/20/2026 |
| DOB NOW | Supported Scaffold | Permit Issued | NEW AMERICAN CONSTRUCTION | 03/24/2026 |
| DOB NOW | Sidewalk Shed | Permit Issued | NEW AMERICAN CONSTRUCTION | 03/10/2026 |
| DOB NOW | Plumbing | Permit Issued | RRP PLUMBING CORP | 01/07/2026 |
| DOB NOW | General Construction | Permit Issued | H BUILDING MANAGEMENT INC | 11/05/2025 |
| DOB NOW | Foundation | Permit Issued | H BUILDING MANAGEMENT INC | 10/31/2025 |
| DOB NOW | Structural | Permit Issued | H BUILDING MANAGEMENT INC | 10/30/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | H BUILDING MANAGEMENT INC | 10/29/2025 |
| DOB NOW | Full Demolition | Signed-off | H BUILDING MANAGEMENT INC | 06/18/2025 |
| DOB NOW | Construction Fence | Permit Issued | H BUILDING MANAGEMENT INC | 06/12/2025 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/08/2026 | Permit Issued | NEW AMERICAN CONSTRUCTION | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-SM36NAMHZ2 36,000 BTU · Condensing Unit ×3 MXZ-SM48NAMHZ2 48,000 BTU · Condensing Unit ×2 MXZ-SM42NAMHZ2 42,000 BTU · Condensing Unit ×1 PUZ-A12NKA7 12,000 BTU · Condensing Unit ×1 Ventilation Greenheck SQ-97-VG 270 CFM · Makeup Air ×4 ERV-20-15L 850 CFM · Erv ×1 USF-13-B3 1,200 CFM · Kitchen Exhaust ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/08/2026 | Permit Issued | RRP PLUMBING CORP | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/08/2026 | Permit Issued | RRP PLUMBING CORP | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/11/2026 | Permit Issued | TUXEDO ELEC'L CONTR'G INC | — |
| 03/05/2026 | Permit Issued | RICHARD NEU | — |
| 12/11/2025 | Permit Issued | SAFEWAY CONSTRUCTION, INC | General Wiring |
| 11/05/2019 | Permit Issued | BLZ ELECTRIC INC. | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/08/2026 | Permit Issued | NEW AMERICAN CONSTRUCTION | Concrete |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/08/2026 | Permit Issued | NEW AMERICAN CONSTRUCTION | Fence, Scaffold, Sidewalk Shed |
| 06/02/2026 | Permit Issued | H BUILDING MANAGEMENT INC | Scaffold |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/27/2026 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 07/27/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 07/24/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 06/15/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 02/13/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 02/05/2026 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/16/2026 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 07/16/2026 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 07/16/2026 | Fenestration areas | FAHAD FATEH | energy_progress |
| 07/16/2026 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 07/16/2026 | Fenestration and door U-factor and product ratings | FAHAD FATEH | energy_progress |
| 07/16/2026 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 07/16/2026 | Lowest Floor Elevation | FAHAD FATEH | progress |
| 07/16/2026 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 07/16/2026 | Fire-Resistance Rated Construction | FAHAD FATEH | progress |
| 06/30/2026 | Lowest Floor Elevation | FAHAD FATEH | progress |
| 06/30/2026 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 06/30/2026 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 06/30/2026 | Fire-Resistance Rated Construction | FAHAD FATEH | progress |
| 06/30/2026 | Fenestration and door U-factor and product ratings | FAHAD FATEH | energy_progress |
| 06/30/2026 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 06/30/2026 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 06/30/2026 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 06/30/2026 | Fenestration areas | FAHAD FATEH | energy_progress |
| 06/03/2026 | Post-installed Anchors | JOEL PHAGOO | special |
| 03/27/2025 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 03/14/2025 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | FAHAD FATEH | special |
| 03/14/2025 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 03/14/2025 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | FAHAD FATEH | special |
| 03/14/2025 | HVAC-R and service water heating equipment | FAHAD FATEH | energy_progress |
| 03/14/2025 | HVAC-R and service water heating system controls | FAHAD FATEH | energy_progress |