← Back
BuildNYC
Two stories - detached, small or mid-size
60 UXBRIDGE STREET
STATEN ISLAND · BIN 5034283
💬 Discuss this project
1970Year Built
2Stories
A1Building Class
R3-1Zoning
2,184 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 4,000 sf lot · 0.55 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalPlumbingCivil
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofPhotovoltaic solar panel installation1 filing · 7 docs
Floor 2Unit PH526p · 2 filings · 20 docs
Floor 1Interior renovation and conversion of garage to finished spa28p · 3 filings · 20 docs
Cellar9p · 1 filing · 9 docs
BasementInterior renovation and conversion of garage to finished spa17p · 1 filing · 20 docs
Sub-Basement9p · 1 filing · 9 docs
Site & exteriorInterior renovation and conversion of garage to finished spa17p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Ryan Design Architecture708/23/2024
NY Building Associates107/31/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S R Solar Design203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Milano of Richmond TownGeneral Contractor707/08/2026
J Synergy GreenGeneral Contractor203/21/2026
Zaim ContractorGeneral Contractor107/08/2026
DPH Plumbing & HeatingPlumbing107/08/2026
HP ServicesPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM Engineering6244107/31/2024
Ryan Design Architecture7159209/29/2022
Building Lifecycle
08/27/2025
Signed off — Alteration CO
S08004726-S1
08/27/2025
Signed off — Alteration CO
S08004726-S2
07/23/2025
Signed off — Alteration
revised plumbing amended as a subsequent filing for legalization S08005176-i1
S08005176-I1
07/22/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/22/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
52 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offMilano of Richmond Town12/16/2024
DOB NOWGeneral ConstructionSigned-offMilano of Richmond Town12/10/2024
DOB NOWSolarSigned-offJ Synergy Green08/29/2024
DOB NOWPlumbingSigned-offHP Services08/12/2024
DOB NOWCurb CutSigned-offSuffolk Construction Co07/19/2023
DOB NOWPlumbingSigned-offDPH Plumbing & Heating12/30/2022
DOB NOWGeneral ConstructionPermit IssuedMilano of Richmond Town12/29/2022
2 projects · most recent 07/31/2024
General Wiring
FiledStatusContractorScope
07/31/2024CompleteGreen Light Electrical & Mechanical—
01/05/2023CompleteA & R Electrical ContractingGeneral Wiring
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
07/22/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/08/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/27/2024Pass-Final CND-Occupancy InspectionPassView ↗
02/09/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/02/2024Pass-Final Curb Cut Non-Directive 14PassView ↗
11/14/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/01/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/01/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/01/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
07/31/2024Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
07/31/2024Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
07/31/2024Energy Code Compliance InspectionsNARESH MAHANGUprogress
07/31/2024FinalNARESH MAHANGUprogress
07/31/2024Air barrier - visual inspectionNARESH MAHANGUenergy_progress
09/23/2022Concrete - Cast-In-PlaceDaniel Ryanspecial
09/23/2022Subgrade InspectionsDaniel Ryanspecial
09/16/2022Fenestration areasDaniel Ryanenergy_progress
09/16/2022Energy Code Compliance InspectionsDaniel Ryanprogress
09/16/2022Fire-Resistance Rated ConstructionDaniel Ryanprogress
09/16/2022Air barrier - visual inspectionDaniel Ryanenergy_progress
09/16/2022Fenestration and door U-factor and product ratingsDaniel Ryanenergy_progress
09/16/2022Fire-Resistant Penetrations and JointsDaniel Ryanspecial
45 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account